Encompass Hip Stem
13mm Distal Centralizer
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Record
| Listed by | Ortho Development Corp., United States |
|---|---|
| FDA product code | KWY |
| Device type | Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3390 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K962448 |
| Record published | 2015-08-31 |
| Record revised | 2023-02-03 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Sizes | Outer diameter 9 to 18 mm |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 114-0009 | Outer Diameter 9 mm | In distribution |
| 114-0013 | Outer Diameter 13 mm | In distribution |
| 114-2016 | Outer Diameter 16 mm | In distribution |
| 114-0016 | Outer Diameter 16 mm | In distribution |
| 114-2009 | Outer Diameter 9 mm | In distribution |
| 114-0011 | Outer Diameter 11 mm | In distribution |
| 114-0015 | Outer Diameter 15 mm | In distribution |
| 114-2012 | Outer Diameter 12 mm | In distribution |
| 114-2014 | Outer Diameter 14 mm | In distribution |
| 114-0012 | Outer Diameter 12 mm | In distribution |
| 114-0010 | Outer Diameter 10 mm | In distribution |
| 114-0017 | Outer Diameter 17 mm | In distribution |
| 114-2010 | Outer Diameter 10 mm | In distribution |
| 114-0018 | Outer Diameter 18 mm | In distribution |
| 114-0014 | Outer Diameter 14 mm | In distribution |
| 114-2018 | Outer Diameter 18 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Resolve Modular Revision Hip Stem | United Orthopedic Corp. | 196 |
| Corin Bipolar Prosthesis | Corin Limited | 182 |
| Consensus® Hip System | Consensus Orthopedics, Inc. | 177 |
| Consensus Hip System | Shalby Advanced Technologies, Inc. | 177 |
| Instrument | Howmedica Osteonics Corp | 130 |
| Bencox Hip System | Corentec Co., Ltd. | 126 |
| United Hip System, U2 Bipolar Implant | United Orthopedic Corp. | 123 |
| MultiPolar® | Zimmer, Inc. | 100 |
| Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented | Zimmer, Inc. | 96 |
| Fitmore® Hip Stem | Zimmer, Inc. | 75 |
| Arcos® Modular Revision System | Biomet Orthopedics | 67 |
| Acumatch L-Series | Exactech, Inc. | 67 |
Showing 12 of 352. All products under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K050966 | 2005-07-07 |
| K982389 | 1998-10-07 |
| K962448 | 1996-09-19 |
| K961793 | 1996-07-26 |
| K953977 | 1996-01-26 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Ortho Development Corp. | 510(k) number | 2010-07-28 | Not classified | Nonconforming Material/Component | The hip stem did not fit the distal centralizer because the hole was not drilled with the appropriate taper. | 39 units | 2010-11-04 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2014-07-11 | Class II | Packaging process control | Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increase | 188 | 2014-10-06 |
| 2009-04-29 | Not classified | Device Design | A Pivot BiPolar Head, the femoral head in a hip prosthesis, might not move freely after assembly due a stacking up of manufacturing tolerances. | 23 | 2010-05-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.