Longevity®

7 catalogue numbers from 20992240, listed by Zimmer, Inc., United States, under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented. 14 manufacturers in China are registered for this product code.

Registry build 21.09.26
14manufacturers in China registered for this device type
7catalogue numbers in this listing
5510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWY
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented

Record

Regulatory record for Longevity®
Listed by Zimmer, Inc., United States
FDA product code KWY
Device type Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Device class Class 2
Regulation 21 CFR 888.3390
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K190656
Record published 2019-12-31

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Sizes Outer diameter 32 to 60 mm; lumen/inner diameter 22.2 to 28 mm

Catalogue Numbers

Catalogue numbers for Longevity®
Catalogue number Size Status
20992240 Outer Diameter 40.00 mm In distribution
20992238 Lumen/Inner Diameter 22.20 mm In distribution
110031007 Lumen/Inner Diameter 28.00 mm In distribution
110030997 Outer Diameter 38.00 mm In distribution
110031311 Size A In distribution
110031008 Lumen/Inner Diameter 28.00 mm In distribution
110031006 Outer Diameter 56.00 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Resolve Modular Revision Hip Stem United Orthopedic Corp. 196
Corin Bipolar Prosthesis Corin Limited 182
Consensus® Hip System Consensus Orthopedics, Inc. 177
Consensus Hip System Shalby Advanced Technologies, Inc. 177
Instrument Howmedica Osteonics Corp 130
Bencox Hip System Corentec Co., Ltd. 126
United Hip System, U2 Bipolar Implant United Orthopedic Corp. 123
MultiPolar® Zimmer, Inc. 100
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented Zimmer, Inc. 96
Fitmore® Hip Stem Zimmer, Inc. 75
Arcos® Modular Revision System Biomet Orthopedics 67
Acumatch L-Series Exactech, Inc. 67

Showing 12 of 352. All products under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K192236 2019-11-05
K170072 2017-02-07
K884658 1988-11-30
K872019 1987-07-21
K833991 1984-01-30

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Longevity®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2025-09-26 Class II Labeling mix-ups Zimmer Biomet is conducting a medical device recall for two (2) lots of the Dual Mobility Vivacit-E Bearing due to a commingle. The outer package is labeled as a Size F 44 mm, however, the implant inside the package is a Size G 46 mm, and v 72 units
Zimmer, Inc. 510(k) number 2025-09-26 Class II Labeling mix-ups Zimmer Biomet is conducting a medical device recall for two (2) lots of the Dual Mobility Vivacit-E Bearing due to a commingle. The outer package is labeled as a Size F 44 mm, however, the implant inside the package is a Size G 46 mm, and v 63 units
Zimmer, Inc. 510(k) number 2020-08-14 Class II Under Investigation by firm The outer package is labeled as a Size C 38 mm, however, the implant inside the package is a Size E 42 mm. 31 2022-06-09

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-11-29 Class II Packaging The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. 13,227 in total 2020-04-02
2016-01-11 Class II Process control LDPE bag containing the implant adheres to the highly polished implant surface. 72806 2017-05-23
2013-10-11 Class II Packaging Zimmer recently conducted a review of all historic packaging validations at its Zimmer Manufacturing B.V. (ZMBV) facility in Ponce, Puerto Rico. Based on this review, it was determined that the packaging operations conducted in the Building 7,044,680 total 2017-04-14
2013-08-30 Class II Package design/selection The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices. 72806 2014-09-25
2012-08-31 Class II Process design Zimmer Inc. is initiating a removal of the Multipolar Bipolar Cup Liner 22 mm J.D. (item 00-5001-040-22) due to reports that the split poly ring was incorrectly assembled. 195 2013-09-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer