Pivot Bipolar

28x59mm Bipolar

Registry build 21.09.26
14manufacturers in China registered for this device type
38catalogue numbers in this listing
5510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWY
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented

Record

Regulatory record for Pivot Bipolar
Listed by Ortho Development Corp., United States
FDA product code KWY
Device type Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Device class Class 2
Regulation 21 CFR 888.3390
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K050966
Record published 2015-08-31
Record revised 2020-09-09 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Sizes Lumen/inner diameter 22 to 28 mm; outer diameter 38 to 60 mm
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Pivot Bipolar
Catalogue number Size Status
133-2859 Lumen/Inner Diameter 28 mm In distribution
133-2255 Lumen/Inner Diameter 22 mm In distribution
133-2856 Lumen/Inner Diameter 28 mm In distribution
133-2246 Outer Diameter 46 mm In distribution
133-2256 Outer Diameter 56 mm In distribution
133-2240 Outer Diameter 40 mm In distribution
133-2238 Outer Diameter 38 mm In distribution
133-2855 Outer Diameter 55 mm In distribution
133-2851 Lumen/Inner Diameter 28 mm In distribution
133-2850 Outer Diameter 50 mm In distribution
133-2243 Lumen/Inner Diameter 22 mm In distribution
133-2242 Outer Diameter 42 mm In distribution
133-2259 Outer Diameter 59 mm In distribution
133-2253 Outer Diameter 53 mm In distribution
133-2239 Lumen/Inner Diameter 22 mm In distribution
133-2257 Outer Diameter 57 mm In distribution
133-2853 Outer Diameter 53 mm In distribution
133-2260 Lumen/Inner Diameter 22 mm In distribution
133-2254 Outer Diameter 54 mm In distribution
133-2849 Lumen/Inner Diameter 28 mm In distribution
133-2241 Lumen/Inner Diameter 22 mm In distribution
133-2258 Lumen/Inner Diameter 22 mm In distribution
133-2248 Outer Diameter 48 mm In distribution
133-2245 Lumen/Inner Diameter 22 mm In distribution
133-2250 Lumen/Inner Diameter 22 mm In distribution
133-2249 Lumen/Inner Diameter 22 mm In distribution
133-2848 Lumen/Inner Diameter 28 mm In distribution
133-2252 Outer Diameter 52 mm In distribution
133-2857 Lumen/Inner Diameter 28 mm In distribution
133-2251 Outer Diameter 51 mm In distribution
133-2846 Outer Diameter 46 mm In distribution
133-2858 Outer Diameter 58 mm In distribution
133-2860 Lumen/Inner Diameter 28 mm In distribution
133-2247 Outer Diameter 47 mm In distribution
133-2244 Outer Diameter 44 mm In distribution
133-2854 Outer Diameter 54 mm In distribution
133-2852 Outer Diameter 52 mm In distribution
133-2847 Outer Diameter 47 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Resolve Modular Revision Hip Stem United Orthopedic Corp. 196
Corin Bipolar Prosthesis Corin Limited 182
Consensus® Hip System Consensus Orthopedics, Inc. 177
Consensus Hip System Shalby Advanced Technologies, Inc. 177
Instrument Howmedica Osteonics Corp 130
Bencox Hip System Corentec Co., Ltd. 126
United Hip System, U2 Bipolar Implant United Orthopedic Corp. 123
MultiPolar® Zimmer, Inc. 100
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented Zimmer, Inc. 96
Fitmore® Hip Stem Zimmer, Inc. 75
Arcos® Modular Revision System Biomet Orthopedics 67
Acumatch L-Series Exactech, Inc. 67

Showing 12 of 352. All products under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K050966 2005-07-07
K982389 1998-10-07
K962448 1996-09-19
K961793 1996-07-26
K953977 1996-01-26

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Pivot Bipolar
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Ortho Development Corp. 510(k) number 2014-07-11 Class II Packaging process control Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increase 188 2014-10-06
Ortho Development Corp. 510(k) number 2009-04-29 Not classified Device Design A Pivot BiPolar Head, the femoral head in a hip prosthesis, might not move freely after assembly due a stacking up of manufacturing tolerances. 23 2010-05-25

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2010-07-28 Not classified Nonconforming Material/Component The hip stem did not fit the distal centralizer because the hole was not drilled with the appropriate taper. 39 units 2010-11-04

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer