Redapt
REDAPT Anteverted Cemented Screw In Trial Liner 36MM X 66-68MM
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (2), Zhejiang (2). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | KWZ |
| Device type | Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3310 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K150790 |
| Record published | 2015-12-11 |
| Record revised | 2025-07-25 (version 9) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: : – |
| Distribution end date | 2019-08-12 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 71354522 | In distribution | |
| 71354523 | In distribution | |
| 71354283 | In distribution | |
| 71354251 | In distribution | |
| 71354252 | In distribution | |
| 71354224 | In distribution | |
| 71354619 | In distribution | |
| 71354543 | In distribution | |
| 71354549 | In distribution | |
| 71354606 | In distribution | |
| 71354612 | In distribution | |
| 71354502 | In distribution | |
| 71354285 | In distribution | |
| 71354296 | In distribution | |
| 71354291 | In distribution | |
| 71354241 | In distribution | |
| 71354552 | In distribution | |
| 71354262 | In distribution | |
| 71354288 | In distribution | |
| 71354538 | In distribution | |
| 71354261 | In distribution | |
| 71354558 | In distribution | |
| 71354270 | Outer Diameter: 70-74 mm | In distribution |
| 71355328 | In distribution | |
| 71354294 | In distribution | |
| 71354607 | In distribution | |
| 71354259 | In distribution | |
| 71354553 | In distribution | |
| 71354535 | In distribution | |
| 71354268 | In distribution | |
| 71354235 | In distribution | |
| 71354243 | In distribution | |
| 71354281 | In distribution | |
| 71354280 | In distribution | |
| 71354250 | In distribution | |
| 71354231 | In distribution | |
| 71354278 | In distribution | |
| 71354257 | In distribution | |
| 71354613 | In distribution | |
| 71354506 | In distribution | |
| 71354248 | In distribution | |
| 71354274 | Withdrawn | |
| 71354275 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DJO Surgical | Encore Medical, L.P. | 159 |
| Instrument | Howmedica Osteonics Corp | 139 |
| ZMR® | Zimmer, Inc. | 103 |
| Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer | Zimmer, Inc. | 69 |
| Arcos Modular Revision System | Biomet Orthopedics | 66 |
| Pinnacle | Depuy Orthopaedics, Inc. | 52 |
| System 12 | Howmedica Osteonics Corp | 47 |
| Restoration | Howmedica Osteonics Corp | 46 |
| R3 | Smith & Nephew, Inc. | 41 |
| Trident | Howmedica Osteonics Corp | 38 |
| Arcos Modular Revision Hip System | Biomet Orthopedics | 37 |
| G7® | Biomet Orthopedics | 37 |
Showing 12 of 165. All products under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K162641 | 2017-06-19 |
| K122139 | 2012-10-16 |
| K111635 | 2011-09-09 |
| K083566 | 2009-03-03 |
| K033442 | 2003-11-26 |
| K021803 | 2002-12-19 |
Recalls
5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2015-05-06 | Class II | Process change control | The R3 Constrained outer liner locking groove diameter is 0.030 inches oversized and may not allow the locking ring to engage into the R3 shell. | 40 units | 2022-04-01 |
| 2015-05-06 | Class II | Process change control | The R3 Constrained outer liner locking groove diameter is 0.030 inches oversized and may not allow the locking ring to engage into the R3 shell. | 32 units | 2022-04-01 |
| 2015-05-06 | Class II | Process change control | The R3 Constrained outer liner locking groove diameter is 0.030 inches oversized and may not allow the locking ring to engage into the R3 shell. | 0 | 2022-04-01 |
| 2015-05-06 | Class II | Process change control | The R3 Constrained outer liner locking groove diameter is 0.030 inches oversized and may not allow the locking ring to engage into the R3 shell. | 12 units | 2022-04-01 |
| 2015-05-06 | Class II | Process change control | The R3 Constrained outer liner locking groove diameter is 0.030 inches oversized and may not allow the locking ring to engage into the R3 shell. | 17 units | 2022-04-01 |
| 2010-08-13 | Not classified | Other | The firm received reports of a femoral head popping out of the liner intraoperatively. | 82 units | 2011-09-21 |
| 2010-08-13 | Not classified | Other | The firm received reports of a femoral head popping out of the liner intraoperatively. | 79 units | 2011-09-21 |
| 2010-08-13 | Not classified | Other | The firm received reports of a femoral head popping out of the liner intraoperatively. | 82 units | 2011-09-21 |
| 2010-08-13 | Not classified | Other | The firm received reports of a femoral head popping out of the liner intraoperatively. | 118 units | 2011-09-21 |
| 2010-08-13 | Not classified | Other | The firm received reports of a femoral head popping out of the liner intraoperatively. | 91 units | 2011-09-21 |
| 2010-08-13 | Not classified | Other | The firm received reports of a femoral head popping out of the liner intraoperatively. | 84 units | 2011-09-21 |
| 2010-08-13 | Not classified | Other | The firm received reports of a femoral head popping out of the liner intraoperatively. | 89 units | 2011-09-21 |
| 2010-08-13 | Not classified | Other | The firm received reports of a femoral head popping out of the liner intraoperatively. | 91 units | 2011-09-21 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P960054 | 1997-06-19 | S-ROM POLY-DIAL CONSTRAINED LINER | Depuy, A Johnson & Johnson Co. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.