Acumatch P Series

8 catalogue numbers from 114-31-06, listed by Exactech, Inc., United States, under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented. 14 manufacturers in China are registered for this product code.

Registry build 21.09.26
14manufacturers in China registered for this device type
8catalogue numbers in this listing
19510(k) clearances naming this product code
26recalls on this code

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LPH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

Record

Regulatory record for Acumatch P Series
Listed by Exactech, Inc., United States
FDA product code LPH
Device type Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Device class Class 2
Regulation 21 CFR 888.3358
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K030236
Record published 2015-08-10
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries expiry date, serial number
Sizes Length 130 to 160 mm

Catalogue Numbers

Catalogue numbers for Acumatch P Series
Catalogue number Size Status
114-31-06 High Offset In distribution
114-31-03 High Offset In distribution
114-31-05 High Offset In distribution
114-31-04 High Offset In distribution
114-31-01 High Offset In distribution
114-31-02 High Offset In distribution
114-31-07 High Offset In distribution
114-31-00 Size 0 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Initia Total Hip System Kyocera Medical Technologies, Inc. 1,000
DJO Surgical Encore Medical, L.P. 624
Pinnacle Depuy Orthopaedics, Inc. 613
Trilogy® Longevity® Zimmer, Inc. 564
Instrument Howmedica Osteonics Corp 369
InSitu Hip System Nextstep Arthropedix 368
Trilogy® Zimmer, Inc. 359
Kyocera Medical Technologies, Inc. Kyocera Medical Technologies, Inc. 298
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented Zimmer, Inc. 286
Bencox Hip System Corentec Co., Ltd. 286
OrthoMedFlex Orthomedflex LLC 257
Sterizo Total Hip System CPM Medical Consultants, LLC. 240

Showing 12 of 792. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K182502 2019-03-13
K141960 2015-09-03
K141797 2014-07-29
K122798 2012-10-11
K121684 2012-10-01
K113609 2012-01-04
K102975 2010-11-05
K101761 2010-09-21
K100269 2010-05-27
K051556 2005-09-06
K041906 2004-09-10
K032964 2003-11-13
K030236 2003-02-20
K011081 2001-04-24
K010120 2001-02-09
K993736 2000-01-20
K993082 1999-11-19
K921113 1993-10-27
K921114 1993-10-27

Recalls

24 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-12-31 Class II Nonconforming Material/Component Due to the lack of the Ethylene Vinyl Alcohol (EVOH) barrier layer. 1446
2023-11-21 Class II Packaging change control Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.
2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 3793 devices
2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 132 devices
2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 11143 DEVICES
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
2016-11-07 Class II Under Investigation by firm Products were labeled with incorrect Global Trade Item Numbers. The GTIN on the label identifies the devices as another. 12 devices 2019-08-05
2013-09-11 Class II Employee error Exactech is recalling the InteGrip Acetabular Augments due to an out of range condition for an in-vitro biological evaluation standard. 235 2014-08-04
2007-11-01 Not classified Process control Mislabeled: A ten piece lot of 140-32-03, 12/14 BIOLOXforte Alumina Femoral Heads 32mm (1069020 – 1069029), from Ceramtec were incorrectly labeled as 140-28-03 12/14 BIOLOXforte Alumina Femoral Heads, 28mm 10 2012-05-06
2006-07-21 Not classified Other The packaging was mislabeled: Exterior and interior packaging on the device was labeled with catalog number 150-07-19 15mm x 200mm, however, the actual part inside the packaging was a 21mm x 200mm (catalog number 150-07-44) device. 6 2012-05-06

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P880025 1991-12-04 AML(R) POROCOAT(R) ACETABULAR CUP PROSTHESIS Depuy Intl., Ltd.
P880076 1991-06-17 WHITESIDE EPS(TM) FEMORAL HIP PROSTHESIS Dow Corning Wright
P850061 1991-03-08 BIAS(R) FIBER METAL TOTAL HIP SYSTEM Zimmer, Inc.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer