MobileLink Acetabular Cup System
Shell/Insert Adapter; neutral; 0° inclination, 0 mm offset
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Record
| Listed by | Waldemar Link GmbH & Co. KG, Germany |
|---|---|
| FDA product code | LPH |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3358 |
| Establishment | Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K222066 |
| Record published | 2023-04-18 |
| Record revised | 2025-06-13 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, serial number |
| Distribution end date | 2025-09-23 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 183-201/48 | In distribution | |
| 183-110/66 | In distribution | |
| 183-852/28 | In distribution | |
| 183-590/06 | In distribution | |
| 183-373/28 | In distribution | |
| 183-371/32 | In distribution | |
| 183-201/44 | In distribution | |
| 183-580/03 | In distribution | |
| 183-580/01 | In distribution | |
| 183-101/46 | In distribution | |
| 183-610/03 | In distribution | |
| 183-863/36 | In distribution | |
| 183-201/46 | In distribution | |
| 183-905/01 | In distribution | |
| 183-201/68 | In distribution | |
| 183-201/72 | In distribution | |
| 183-310/52 | In distribution | |
| 183-110/68 | In distribution | |
| 183-101/56 | In distribution | |
| 183-864/28 | In distribution | |
| 183-590/03 | In distribution | |
| 183-201/54 | In distribution | |
| 183-854/32 | In distribution | |
| 183-600/02 | In distribution | |
| 183-861/28 | In distribution | |
| 183-853/36 | In distribution | |
| 183-201/66 | In distribution | |
| 183-310/64 | In distribution | |
| 183-375/28 | In distribution | |
| 183-201/70 | In distribution | |
| 183-310/58 | In distribution | |
| 183-301/60 | In distribution | |
| 183-401/60 | In distribution | |
| 183-401/78 | In distribution | |
| 183-610/05 | In distribution | |
| 183-401/66 | In distribution | |
| 183-401/58 | In distribution | |
| 183-101/52 | In distribution | |
| 183-372/32 | In distribution | |
| 183-401/76 | In distribution | |
| 183-301/74 | In distribution | |
| 183-851/28 | In distribution | |
| 183-101/48 | In distribution | |
| 183-310/74 | In distribution | |
| 183-110/56 | In distribution | |
| 183-201/62 | In distribution | |
| 183-856/36 | In distribution | |
| 183-862/28 | In distribution | |
| 183-362/28 | In distribution | |
| 183-600/05 | In distribution | |
| 183-610/02 | In distribution | |
| 183-110/54 | In distribution | |
| 183-101/70 | In distribution | |
| 183-363/28 | In distribution | |
| 183-110/62 | In distribution | |
| 183-401/64 | In distribution | |
| 183-201/64 | In distribution | |
| 183-370/28 | In distribution | |
| 183-101/42 | In distribution | |
| 183-310/76 | In distribution | |
| 183-201/60 | In distribution | |
| 183-710/00 | In distribution | |
| 183-401/62 | In distribution | |
| 183-266/28 | Withdrawn | |
| 183-706/28 | Withdrawn | |
| 183-262/32 | Withdrawn | |
| 183-251/28 | Withdrawn | |
| 183-253/28 | Withdrawn | |
| 183-252/28 | Withdrawn | |
| 183-254/28 | Withdrawn | |
| 183-255/32 | Withdrawn | |
| 183-264/28 | Withdrawn | |
| 183-701/28 | Withdrawn | |
| 183-253/32 | Withdrawn | |
| 183-705/32 | Withdrawn | |
| 183-263/28 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Initia Total Hip System | Kyocera Medical Technologies, Inc. | 1,000 |
| DJO Surgical | Encore Medical, L.P. | 624 |
| Pinnacle | Depuy Orthopaedics, Inc. | 613 |
| Trilogy® Longevity® | Zimmer, Inc. | 564 |
| Instrument | Howmedica Osteonics Corp | 369 |
| InSitu Hip System | Nextstep Arthropedix | 368 |
| Trilogy® | Zimmer, Inc. | 359 |
| Kyocera Medical Technologies, Inc. | Kyocera Medical Technologies, Inc. | 298 |
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented | Zimmer, Inc. | 286 |
| Bencox Hip System | Corentec Co., Ltd. | 286 |
| OrthoMedFlex | Orthomedflex LLC | 257 |
| Sterizo Total Hip System | CPM Medical Consultants, LLC. | 240 |
Showing 12 of 792. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K241636 | 2024-11-08 |
| K222066 | 2023-04-14 |
| K200607 | 2021-05-28 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Waldemar Link GmbH & Co. KG | 510(k) number | 2023-07-14 | Class II | Under Investigation by firm | Product is labeled with incorrect offset. | 8 units |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P880025 | 1991-12-04 | AML(R) POROCOAT(R) ACETABULAR CUP PROSTHESIS | Depuy Intl., Ltd. |
| P880076 | 1991-06-17 | WHITESIDE EPS(TM) FEMORAL HIP PROSTHESIS | Dow Corning Wright |
| P850061 | 1991-03-08 | BIAS(R) FIBER METAL TOTAL HIP SYSTEM | Zimmer, Inc. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.