Polarcup

Polarcup Shell TI-Plasma/HA 49 NON-Cemented

Registry build 21.09.26
14manufacturers in China registered for this device type
53catalogue numbers in this listing
32510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LPH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

Record

Regulatory record for Polarcup
Listed by Smith & Nephew, Inc., United States
FDA product code LPH
Device type Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Device class Class 2
Regulation 21 CFR 888.3358
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K110135
Record published 2015-08-29
Record revised 2025-08-13 (version 10)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Special storage condition: : –

Catalogue Numbers

Catalogue numbers for Polarcup
Catalogue number Size Status
75100458 In distribution
75100456 In distribution
75018946 In distribution
75100410 In distribution
75023366 In distribution
75100195 In distribution
75023714 In distribution
75018956 In distribution
75000656 In distribution
75000657 In distribution
75000653 In distribution
75100454 In distribution
75100417 In distribution
75017099 In distribution
75018958 In distribution
75000654 In distribution
75000655 In distribution
75000659 In distribution
75018962 In distribution
75100408 In distribution
75018964 In distribution
75000661 In distribution
75100409 In distribution
75100460 In distribution
75018960 In distribution
75100461 In distribution
75100418 In distribution
75000663 In distribution
75000648 In distribution
75100439 In distribution
75100451 In distribution
75018957 In distribution
75100459 In distribution
75100452 In distribution
75018953 In distribution
75000658 In distribution
75018948 In distribution
75100453 In distribution
75100455 In distribution
75100411 In distribution
75017102 In distribution
75017130 In distribution
75023368 In distribution
75023367 In distribution
75100457 In distribution
75100412 In distribution
75018955 In distribution
75018944 In distribution
75000662 In distribution
75100413 In distribution
75018959 In distribution
75017101 In distribution
75017138 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Initia Total Hip System Kyocera Medical Technologies, Inc. 1,000
DJO Surgical Encore Medical, L.P. 624
Pinnacle Depuy Orthopaedics, Inc. 613
Trilogy® Longevity® Zimmer, Inc. 564
Instrument Howmedica Osteonics Corp 369
InSitu Hip System Nextstep Arthropedix 368
Trilogy® Zimmer, Inc. 359
Kyocera Medical Technologies, Inc. Kyocera Medical Technologies, Inc. 298
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented Zimmer, Inc. 286
Bencox Hip System Corentec Co., Ltd. 286
OrthoMedFlex Orthomedflex LLC 257
Sterizo Total Hip System CPM Medical Consultants, LLC. 240

Showing 12 of 792. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K242375 2024-10-07
K232667 2023-10-27
K220959 2022-08-18
K211176 2022-07-01
K211330 2022-01-19
K191002 2019-10-31
K190847 2019-10-25
K182109 2018-11-16
K181366 2018-09-24
K171934 2017-11-30
K171073 2017-11-21
K172684 2017-10-03
K150790 2015-11-16
K123012 2012-10-24
K122244 2012-08-23
K110135 2011-10-14
K103256 2011-01-31
K092098 2010-01-22
K081566 2008-08-21
K072817 2008-05-15
K080625 2008-05-08
K072417 2008-01-10
K071160 2007-10-05
K060630 2006-06-14
K022902 2002-10-02
K022556 2002-08-28
K012787 2002-03-15
K013658 2001-12-05
K002747 2000-12-15
K991026 1999-10-22
K991485 1999-07-12
K983834 1999-02-24

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Polarcup
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Smith & Nephew, Inc. 510(k) number 2024-10-15 Class II Under Investigation by firm The Bipolar assembly contains an oversized Retainer Ring. 21 devices

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-02-19 Class II Packaging process control Complaints were received indicating that the outer label incorrectly identified the product as size “1” instead of “-1”. The product contained within the package is size “-1” 58 units 2021-05-21
2019-02-19 Class II Packaging process control Complaints were received indicating that the outer label incorrectly identified the product as size “1” instead of “-1”. The product contained within the package is size “-1” 9 units 2021-05-21
2013-11-25 Class II Other One batch of the Reflection(TM) Polyethylene Acetabular Liners may be out of tolerance causing the liner not to fully seat into the shell. 38 units 2017-02-01
2008-11-21 Not classified Process control Liners measuring 28 mm ID and were mismarked as 32 mm. 19 units 2011-11-21

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P880025 1991-12-04 AML(R) POROCOAT(R) ACETABULAR CUP PROSTHESIS Depuy Intl., Ltd.
P880076 1991-06-17 WHITESIDE EPS(TM) FEMORAL HIP PROSTHESIS Dow Corning Wright
P850061 1991-03-08 BIAS(R) FIBER METAL TOTAL HIP SYSTEM Zimmer, Inc.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer