Reflection
Reflection Xlpe 28MM Inner Diameter 0 Degree Lateralized +4MM 58-60MM Outer Diameter Size G ETO
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | LPH |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3358 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K022556 |
| Record published | 2015-08-30 |
| Record revised | 2025-10-08 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: : – |
| Distribution end date | 2022-03-17 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 71332571 | In distribution | |
| 71333399 | In distribution | |
| 71332561 | In distribution | |
| 71333356 | In distribution | |
| 71353255 | In distribution | |
| 71934725 | In distribution | |
| 71334576 | In distribution | |
| 71334573 | In distribution | |
| 71332526 | In distribution | |
| 71333355 | In distribution | |
| 71923740 | In distribution | |
| 71331082 | In distribution | |
| 71923738 | In distribution | |
| 71334551 | In distribution | |
| 71333397 | In distribution | |
| 71352246 | In distribution | |
| 71333346 | In distribution | |
| 71352849 | In distribution | |
| 71333499 | In distribution | |
| 71332541 | In distribution | |
| 71335158 | In distribution | |
| 71333347 | In distribution | |
| 743070 | In distribution | |
| 71331315 | In distribution | |
| 71331089 | In distribution | |
| 71330046 | In distribution | |
| 71353252 | In distribution | |
| 71331068 | In distribution | |
| 71331066 | In distribution | |
| 71335166 | In distribution | |
| 71331064 | In distribution | |
| 71331088 | In distribution | |
| 71334515 | In distribution | |
| 71331314 | In distribution | |
| 71339946 | In distribution | |
| 71333349 | In distribution | |
| 71352249 | In distribution | |
| 71333496 | In distribution | |
| 71331311 | In distribution | |
| 71352858 | In distribution | |
| 71333345 | In distribution | |
| 71332528 | In distribution | |
| 71742062 | In distribution | |
| 71335152 | In distribution | |
| 746615 | In distribution | |
| 71333398 | In distribution | |
| 71335160 | In distribution | |
| 71331072 | In distribution | |
| 71331090 | In distribution | |
| 71333446 | In distribution | |
| 71334502 | In distribution | |
| 71332551 | In distribution | |
| 71331316 | In distribution | |
| 71352861 | In distribution | |
| 71333449 | In distribution | |
| 71332531 | In distribution | |
| 71333408 | In distribution | |
| 71334575 | In distribution | |
| 71331056 | In distribution | |
| 71334523 | In distribution | |
| 71334524 | In distribution | |
| 71921436 | In distribution | |
| 71333447 | In distribution | |
| 71335162 | In distribution | |
| 71352243 | In distribution | |
| 71930640 | In distribution | |
| 71352258 | In distribution | |
| 71352846 | In distribution | |
| 71352255 | In distribution | |
| 71333498 | In distribution | |
| 71930638 | In distribution | |
| 71330466 | In distribution | |
| 71352252 | In distribution | |
| 71921435 | In distribution | |
| 71930643 | In distribution | |
| 71331062 | In distribution | |
| 71332536 | In distribution | |
| 71333396 | In distribution | |
| 71930655 | In distribution | |
| 71353258 | In distribution | |
| 71353261 | In distribution | |
| 71331091 | In distribution | |
| 71334512 | In distribution | |
| 71334526 | In distribution | |
| 71334527 | In distribution | |
| 71331060 | In distribution | |
| 71332556 | In distribution | |
| 71332538 | In distribution | |
| 71335156 | In distribution | |
| 71335154 | In distribution | |
| 71352261 | In distribution | |
| 71934727 | In distribution | |
| 71331070 | In distribution | |
| 71921434 | In distribution | |
| 71930645 | In distribution | |
| 71333348 | In distribution | |
| 71335150 | In distribution | |
| 71930649 | In distribution | |
| 71352852 | In distribution | |
| 71331058 | In distribution | |
| 71923739 | In distribution | |
| 71333445 | In distribution | |
| 71335164 | In distribution | |
| 71352240 | In distribution | |
| 71930642 | In distribution | |
| 71335168 | In distribution | |
| 71352855 | In distribution | |
| 71334574 | In distribution | |
| 71930639 | In distribution | |
| 71333448 | In distribution | |
| 71334514 | In distribution | |
| 71332566 | In distribution | |
| 71353249 | In distribution | |
| 71930644 | In distribution | |
| 71333395 | In distribution | |
| 71333497 | In distribution | |
| 71333368 | In distribution | |
| 71334562 | In distribution | |
| 71332546 | In distribution | |
| 71923734 | In distribution | |
| 71334525 | In distribution | |
| 71334513 | In distribution | |
| 71930641 | In distribution | |
| 71333357 | In distribution | |
| 71333495 | In distribution | |
| 71934726 | In distribution | |
| 743052 | Withdrawn | |
| 71335456 | Withdrawn | |
| 71921442 | Withdrawn | |
| 71335262 | Withdrawn | |
| 71335256 | Withdrawn | |
| 743060 | Withdrawn | |
| 71335464 | Withdrawn | |
| 71335480 | Withdrawn | |
| 71335258 | Withdrawn | |
| 71335476 | Withdrawn | |
| 740068 | Withdrawn | |
| 71925456 | Withdrawn | |
| 71335472 | Withdrawn | |
| 740070 | Withdrawn | |
| 743068 | Withdrawn | |
| 71335462 | Withdrawn | |
| 71335254 | Withdrawn | |
| 740048 | Withdrawn | |
| 743044 | Withdrawn | |
| 71923737 | Withdrawn | |
| 71335454 | Withdrawn | |
| 71923735 | Withdrawn | |
| 71921443 | Withdrawn | |
| 743064 | Withdrawn | |
| 71335260 | Withdrawn | |
| 71921441 | Withdrawn | |
| 71335266 | Withdrawn | |
| 71335252 | Withdrawn | |
| 743066 | Withdrawn | |
| 71335268 | Withdrawn | |
| 71335470 | Withdrawn | |
| 743062 | Withdrawn | |
| 71335474 | Withdrawn | |
| 743058 | Withdrawn | |
| 71335250 | Withdrawn | |
| 71923736 | Withdrawn | |
| 71335468 | Withdrawn | |
| 71335460 | Withdrawn | |
| 71335478 | Withdrawn | |
| 71335458 | Withdrawn | |
| 71335264 | Withdrawn | |
| 71335466 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Initia Total Hip System | Kyocera Medical Technologies, Inc. | 1,000 |
| DJO Surgical | Encore Medical, L.P. | 624 |
| Pinnacle | Depuy Orthopaedics, Inc. | 613 |
| Trilogy® Longevity® | Zimmer, Inc. | 564 |
| Instrument | Howmedica Osteonics Corp | 369 |
| InSitu Hip System | Nextstep Arthropedix | 368 |
| Trilogy® | Zimmer, Inc. | 359 |
| Kyocera Medical Technologies, Inc. | Kyocera Medical Technologies, Inc. | 298 |
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented | Zimmer, Inc. | 286 |
| Bencox Hip System | Corentec Co., Ltd. | 286 |
| OrthoMedFlex | Orthomedflex LLC | 257 |
| Sterizo Total Hip System | CPM Medical Consultants, LLC. | 240 |
Showing 12 of 792. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K242375 | 2024-10-07 |
| K232667 | 2023-10-27 |
| K220959 | 2022-08-18 |
| K211176 | 2022-07-01 |
| K211330 | 2022-01-19 |
| K191002 | 2019-10-31 |
| K190847 | 2019-10-25 |
| K182109 | 2018-11-16 |
| K181366 | 2018-09-24 |
| K171934 | 2017-11-30 |
| K171073 | 2017-11-21 |
| K172684 | 2017-10-03 |
| K150790 | 2015-11-16 |
| K123012 | 2012-10-24 |
| K122244 | 2012-08-23 |
| K110135 | 2011-10-14 |
| K103256 | 2011-01-31 |
| K092098 | 2010-01-22 |
| K081566 | 2008-08-21 |
| K072817 | 2008-05-15 |
| K080625 | 2008-05-08 |
| K072417 | 2008-01-10 |
| K071160 | 2007-10-05 |
| K060630 | 2006-06-14 |
| K022902 | 2002-10-02 |
| K022556 | 2002-08-28 |
| K012787 | 2002-03-15 |
| K013658 | 2001-12-05 |
| K002747 | 2000-12-15 |
| K991026 | 1999-10-22 |
| K991485 | 1999-07-12 |
| K983834 | 1999-02-24 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2019-02-19 | Class II | Packaging process control | Complaints were received indicating that the outer label incorrectly identified the product as size “1” instead of “-1”. The product contained within the package is size “-1” | 58 units | 2021-05-21 |
| 2019-02-19 | Class II | Packaging process control | Complaints were received indicating that the outer label incorrectly identified the product as size “1” instead of “-1”. The product contained within the package is size “-1” | 9 units | 2021-05-21 |
| 2013-11-25 | Class II | Other | One batch of the Reflection(TM) Polyethylene Acetabular Liners may be out of tolerance causing the liner not to fully seat into the shell. | 38 units | 2017-02-01 |
| 2008-11-21 | Not classified | Process control | Liners measuring 28 mm ID and were mismarked as 32 mm. | 19 units | 2011-11-21 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P880025 | 1991-12-04 | AML(R) POROCOAT(R) ACETABULAR CUP PROSTHESIS | Depuy Intl., Ltd. |
| P880076 | 1991-06-17 | WHITESIDE EPS(TM) FEMORAL HIP PROSTHESIS | Dow Corning Wright |
| P850061 | 1991-03-08 | BIAS(R) FIBER METAL TOTAL HIP SYSTEM | Zimmer, Inc. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.