Kinectiv®

41 catalogue numbers from 00-7848-014-01, listed by Zimmer, Inc., United States, under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented. 9 manufacturers in China are registered for this product code.

Registry build 21.09.26
9manufacturers in China registered for this device type
41catalogue numbers in this listing
2510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Concentrated in Jiangsu (4), Shanghai (2), Zhejiang (2). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LWJ
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Kinectiv®
Listed by Zimmer, Inc., United States
FDA product code LWJ
Device type Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
Device class Class 2
Regulation 21 CFR 888.3360
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K071856
Record published 2018-09-14
Record revised 2020-11-19 (version 6)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Kinectiv®
Catalogue number Size Status
00-7848-014-01 12/14 Neck Taper In distribution
00-7713-016-00 Size 16.25 In distribution
00-7848-011-01 12/14 Neck Taper In distribution
65-7713-009-00 Size 9 In distribution
00-7805-012-01 In distribution
00-7848-030-01 12/14 Neck Taper In distribution
00-7805-020-01 In distribution
65-7713-016-00 Size 16.25 In distribution
00-7848-003-00 12/14 Neck Taper In distribution
00-7713-010-00 Size 10 In distribution
00-7848-033-00 12/14 Neck Taper In distribution
00-7848-032-01 12/14 Neck Taper In distribution
00-7713-005-00 Size 5 In distribution
00-7848-013-01 12/14 Neck Taper In distribution
00-7848-012-01 12/14 Neck Taper In distribution
00-7805-003-01 In distribution
00-7848-012-01 12/14 Neck Taper In distribution
00-7848-022-01 12/14 Neck Taper In distribution
00-7848-022-00 12/14 Neck Taper In distribution
00-7713-022-00 Size 22.5 In distribution
00-7848-023-01 12/14 Neck Taper In distribution
00-7713-013-00 Size 13.5 In distribution
65-7713-015-00 Size 15 In distribution
00-7805-002-01 In distribution
00-7848-032-01 12/14 Neck Taper In distribution
00-7848-021-01 12/14 Neck Taper In distribution
00-7805-041-01 In distribution
00-7848-044-01 12/14 Neck Taper In distribution
65-7713-007-00 Size 7.5 In distribution
00-7848-013-01 12/14 Neck Taper In distribution
00-7848-042-01 12/14 Neck Taper In distribution
00-7848-033-01 12/14 Neck Taper In distribution
00-7848-011-01 12/14 Neck Taper In distribution
00-7713-009-00 Size 9 In distribution
00-7848-012-00 12/14 Neck Taper In distribution
00-7848-011-00 12/14 Neck Taper In distribution
00-7848-020-01 12/14 Neck Taper In distribution
00-7848-034-01 12/14 Neck Taper In distribution
00-7848-014-01 12/14 Neck Taper In distribution
00-7713-015-00 Size 15 In distribution
00-7848-043-01 12/14 Neck Taper In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Iconacy i-Hip Iconacy Orthopedic Implants, LLC 154
ZMR® Zimmer, Inc. 129
Instrument Howmedica Osteonics Corp 120
Restoration Howmedica Osteonics Corp 66
U2 Hip Stem United Orthopedic Corp. 60
Trinity Acetabular Hip System Corin Limited 58
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented Exactech, Inc. 51
Omnifit Howmedica Osteonics Corp 48
Novation Exactech, Inc. 48
Endo-Model SL Knee Prosthesis System Waldemar Link GmbH & Co. KG 46
Trident Howmedica Osteonics Corp 43
Aesculap Aesculap AG 38

Showing 12 of 131. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K961378 1996-10-08
K952776 1996-02-14

Recalls Naming This Product

6 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Kinectiv®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2019-10-10 Class II Packaging change control Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). 5,459,583 total devices 2020-05-19
Zimmer, Inc. 510(k) number 2018-05-30 Class II Packaging M/L Taper Hip Prosthesis and M/L Taper Hip Prosthesis with Kinectiv Technology manufactured prior to October 2015 are being recalled due to the potential for black residue to be observed within the polyethylene bag containing the implant. T 96 2020-05-28
Zimmer, Inc. 510(k) number 2018-05-30 Class II Packaging 24 2020-05-28
Zimmer, Inc. 510(k) number 2018-05-30 Class II Packaging M/L Taper Hip Prosthesis and M/L Taper Hip Prosthesis with Kinectiv Technology manufactured prior to October 2015 are being recalled due to the potential for black residue to be observed within the polyethylene bag containing the implant. T 116 2020-05-28
Zimmer, Inc. 510(k) number 2015-05-18 Class I Environmental control Zimmer is initiating a voluntary recall of 64 lots (752 implants total) of M/L Taper with Kinectiv femoral stems and modular necks due higher than allowed cytotoxicity levels found with the product. Reasonable probability of adverse biolog 752 2016-08-02
Zimmer, Inc. 510(k) number 2009-05-29 Not classified Packaging process control The corner tab of the inner compartment lid was not folded under before the outer lid was sealed, resulting in lack of assurance of sterility. 147 of both products. 2009-12-22

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2013-10-11 Class II Packaging Zimmer recently conducted a review of all historic packaging validations at its Zimmer Manufacturing B.V. (ZMBV) facility in Ponce, Puerto Rico. Based on this review, it was determined that the packaging operations conducted in the Building 7,044,680 total 2017-04-14
2009-05-15 Not classified Process control The threads on the screw are incomplete/non-functional. 10 2009-11-12
2006-08-02 Not classified Other Lack of assurance of proper metal fatigue strength due to a metal grain structure anomaly. 181 of all devices 2007-05-04
2006-08-02 Not classified Other Lack of assurance of proper metal fatigue strength due to a metal grain structure anomaly. 181 of all devices 2007-05-04
2006-08-02 Not classified Other Lack of assurance of proper metal fatigue strength due to a metal grain structure anomaly. 181 of all devices 2007-05-04
2006-08-02 Not classified Other Lack of assurance of proper metal fatigue strength due to a metal grain structure anomaly. 181 of all devices 2007-05-04

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer