AcuMatch M-Series
7 catalogue numbers from 150-32-25, listed by Exactech, Inc., United States, under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented. 15 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (8), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 15. All 15 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Record
| Listed by | Exactech, Inc., United States |
|---|---|
| FDA product code | LZO |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3353 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K051858 |
| Record published | 2015-10-30 |
| Record revised | 2025-08-27 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | expiry date, serial number |
| Sizes | Outer diameter 21 to 29 mm |
| Distribution end date | 2024-06-13 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 150-32-25 | Outer Diameter 25 mm | Withdrawn |
| 158-02-05 | 12/14 | Withdrawn |
| 150-32-21 | Outer Diameter 21 mm | Withdrawn |
| 150-32-29 | Outer Diameter 29 mm | Withdrawn |
| 158-02-07 | 12/14 | Withdrawn |
| 158-02-03 | 12/14 | Withdrawn |
| 158-02-01 | 12/14 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Libertas | Maxx Orthopedics Inc. | 1,832 |
| Redapt | Smith & Nephew, Inc. | 326 |
| Bencox Hip System | Corentec Co., Ltd. | 295 |
| M-Vizion Femoral Revision System | Medacta International SA | 289 |
| Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Zimmer, Inc. | 280 |
| Profemur® | Microport Orthopedics Inc. | 229 |
| DJO Surgical | Encore Medical, L.P. | 162 |
| Instrument | Howmedica Osteonics Corp | 152 |
| Alteon | Exactech, Inc. | 151 |
| Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Exactech, Inc. | 136 |
| Resolve Modular Revision Hip Stem | United Orthopedic Corp. | 136 |
| Wagner SL Revision® | Zimmer, Inc. | 133 |
Showing 12 of 691. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K221323 | 2023-05-19 |
| K190890 | 2019-10-22 |
| K182462 | 2018-11-08 |
| K181532 | 2018-09-04 |
| K150066 | 2015-07-20 |
| K141821 | 2014-08-28 |
| K140674 | 2014-06-30 |
| K121392 | 2013-01-16 |
| K103012 | 2010-11-10 |
| K102487 | 2010-11-08 |
| K083392 | 2008-12-17 |
| K070479 | 2007-03-15 |
| K063279 | 2006-11-29 |
| K060107 | 2006-02-06 |
| K052787 | 2005-12-27 |
| K051858 | 2005-12-01 |
| K050398 | 2005-11-18 |
| K051682 | 2005-07-19 |
| K042842 | 2004-11-09 |
| K931617 | 1994-06-14 |
| K914574 | 1992-01-13 |
Recalls
15 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-08-11 | Class II | Process control | Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. | 58158 devices | |
| 2022-08-11 | Class II | Process control | Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. | 17929 units | |
| 2021-06-29 | Class II | Under Investigation by firm | Biolox Delta Femoral Head was packaged and labeled as 170-36-00 (36mm +0), but the device was marked as 170-36-03 (36mm +3.5). | 29 devices | |
| 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total | |
| 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total | |
| 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total | |
| 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total | |
| 2021-06-29 | Class II | Under Investigation by firm | Biolox Delta Femoral Head was packaged and labeled as 170-36-00 (36mm +0), but the device was marked as 170-36-03 (36mm +3.5). | 30 devices | |
| 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total | |
| 2016-11-07 | Class II | Under Investigation by firm | Products were labeled with incorrect Global Trade Item Numbers. The GTIN on the label identifies the devices as another. | 98 | 2019-08-05 |
| 2016-05-26 | Class II | Under Investigation by firm | Labeled with the incorrect Global Trade Item Number (GTIN). The GTIN on the label identifies the devices as another. | 14 | 2019-07-26 |
| 2016-05-26 | Class II | Under Investigation by firm | Labeled with the incorrect Global Trade Item Number (GTIN). The GTIN on the label identifies the devices as another. | 8 units | 2019-07-26 |
| 2014-03-07 | Class II | Component design/selection | The femoral stem is lacking specified plasma coating. | 10 | 2014-08-04 |
| 2012-11-05 | Class II | Labeling mix-ups | Recall of Novation Crown Cup Connection GXL Neutral Liners Catalog No. (130-32-53) and Novation Crown Cup Connection GXL + 5mm Lateralized Liners Catalog No. (136-32-53). Exactech discovered the device labeling was inadvertently transposed | 26 Units | 2013-12-24 |
| 2012-11-05 | Class II | Labeling mix-ups | Recall of Novation Crown Cup Connection GXL Neutral Liners Catalog No. (130-32-53) and Novation Crown Cup Connection GXL + 5mm Lateralized Liners Catalog No. (136-32-53). Exactech discovered the device labeling was inadvertently transposed | 26 Units | 2013-12-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.