Biolox® Delta Option Hip System

2 catalogue numbers from 650-1055, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented. 15 manufacturers in China are registered for this product code.

Registry build 21.09.26
15manufacturers in China registered for this device type
2catalogue numbers in this listing
1510(k) clearance

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LZO
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 15. All 15 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

Record

Regulatory record for Biolox® Delta Option Hip System
Listed by Biomet Orthopedics, United States
FDA product code LZO
Device type Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Device class Class 2
Regulation 21 CFR 888.3353
510(k) K082996
Record published 2018-11-13
Record revised 2025-05-30 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Biolox® Delta Option Hip System
Catalogue number Size Status
650-1055 Type 16/18 Taper 28mm Head Ø In distribution
650-1055 28MM HEAD Ø TYPE 16/18 TAPER In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Libertas Maxx Orthopedics Inc. 1,832
Redapt Smith & Nephew, Inc. 326
Bencox Hip System Corentec Co., Ltd. 295
M-Vizion Femoral Revision System Medacta International SA 289
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Zimmer, Inc. 280
Profemur® Microport Orthopedics Inc. 229
DJO Surgical Encore Medical, L.P. 162
Instrument Howmedica Osteonics Corp 152
Alteon Exactech, Inc. 151
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Exactech, Inc. 136
Resolve Modular Revision Hip Stem United Orthopedic Corp. 136
Wagner SL Revision® Zimmer, Inc. 133

Showing 12 of 691. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K200196 2020-12-08

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Biolox® Delta Option Hip System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2024-08-08 Class II Under Investigation by firm Mislabeled: Incorrect sleeve in the packaging. The outer packaging is labeled as a standard neck sleeve, however, the product within the box is a -6mm neck sleeve, and vice versa. The neck of the sleeve can be identified by the device etchi 69 units
Zimmer, Inc. 510(k) number 2024-08-08 Class II Under Investigation by firm Mislabeled: Incorrect sleeve in the packaging. The outer packaging is labeled as a standard neck sleeve, however, the product within the box is a -6mm neck sleeve, and vice versa. The neck of the sleeve can be identified by the device etchi 58 units
Biomet, Inc. 510(k) number 2017-06-05 Class II Labeling False and Misleading Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. 2018-03-06
Biomet, Inc. 510(k) number 2017-06-05 Class II Labeling False and Misleading Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. 2018-03-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer