EcoFit® Short Stem Standard Cementless Cpti
10 catalogue numbers from 30320100, listed by implantcast GmbH, Germany, under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented. 15 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (8), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 15. All 15 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Record
| Listed by | implantcast GmbH, Germany |
|---|---|
| FDA product code | LZO |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3353 |
| Establishment | Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2017-10-31 |
| Record revised | 2023-10-23 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 30320100 | Size 10mm | In distribution |
| 30320075 | Size 7.5mm | In distribution |
| 30321500 | Size 15mm | In distribution |
| 30320125 | Size 12.5mm | In distribution |
| 30320200 | Size 20mm | In distribution |
| 30321125 | Size 11.25mm | In distribution |
| 30320175 | Size 17.5mm | In distribution |
| 30320625 | Size 6.25mm | In distribution |
| 30320875 | Size 8.75mm | In distribution |
| 30321375 | Size 13.75mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Libertas | Maxx Orthopedics Inc. | 1,832 |
| Redapt | Smith & Nephew, Inc. | 326 |
| Bencox Hip System | Corentec Co., Ltd. | 295 |
| M-Vizion Femoral Revision System | Medacta International SA | 289 |
| Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Zimmer, Inc. | 280 |
| Profemur® | Microport Orthopedics Inc. | 229 |
| DJO Surgical | Encore Medical, L.P. | 162 |
| Instrument | Howmedica Osteonics Corp | 152 |
| Alteon | Exactech, Inc. | 151 |
| Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Exactech, Inc. | 136 |
| Resolve Modular Revision Hip Stem | United Orthopedic Corp. | 136 |
| Wagner SL Revision® | Zimmer, Inc. | 133 |
Showing 12 of 691. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K260037 | 2026-03-30 |
| K252401 | 2026-03-12 |
| K240391 | 2024-10-24 |
| K240834 | 2024-06-03 |
| K232371 | 2023-10-19 |
| K223103 | 2023-06-20 |
| K210678 | 2022-08-17 |
| K203420 | 2021-02-03 |
| K180263 | 2018-07-20 |
| K163577 | 2017-09-25 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2021-05-10 | Class II | Device Design | A risk exists during impacting of the acetabular cup into the bone the plugs may come loose from the cup, which could lead to operation duration extension or revision operation. A warning note is being added to instructions for use and surg | 41 units (U.S.) | 2022-11-18 |
| 2017-12-28 | Class II | Process design | Possibility that the retaining ring in the 2M inlay 15degree for MUTARS RS Cup and LUMiC TiN is incorrectly mounted. | 304, 3 in US | 2020-09-01 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.