Fitmore® Hip Stem
Fitmore Hip Stem B Ext. Offs., Size 12
Who Else Makes It
Concentrated in Jiangsu (8), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 15. All 15 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Record
| Listed by | Zimmer, Inc., United States |
|---|---|
| FDA product code | LZO |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3353 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| Record published | 2015-10-16 |
| Record revised | 2023-06-27 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 01.00551.407 | 7 | In distribution |
| 01.00551.408 | 8 | In distribution |
| 01.00551.405 | 5 | In distribution |
| 01.00551.409 | 9 | In distribution |
| 01.00559.210 | In distribution | |
| 01.00551.412 | 12 | In distribution |
| 01.00559.313 | In distribution | |
| 01.00551.306 | 6 | In distribution |
| 01.00551.307 | 7 | In distribution |
| 01.00551.312 | 12 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Libertas | Maxx Orthopedics Inc. | 1,832 |
| Redapt | Smith & Nephew, Inc. | 326 |
| Bencox Hip System | Corentec Co., Ltd. | 295 |
| M-Vizion Femoral Revision System | Medacta International SA | 289 |
| Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Zimmer, Inc. | 280 |
| Profemur® | Microport Orthopedics Inc. | 229 |
| DJO Surgical | Encore Medical, L.P. | 162 |
| Instrument | Howmedica Osteonics Corp | 152 |
| Alteon | Exactech, Inc. | 151 |
| Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Exactech, Inc. | 136 |
| Resolve Modular Revision Hip Stem | United Orthopedic Corp. | 136 |
| Wagner SL Revision® | Zimmer, Inc. | 133 |
Showing 12 of 691. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K260831 | 2026-06-16 |
| K260182 | 2026-04-27 |
| K251906 | 2025-07-18 |
| K200112 | 2020-04-10 |
| K192660 | 2020-02-28 |
| K193050 | 2019-12-26 |
| K192189 | 2019-12-18 |
| K193030 | 2019-12-06 |
| K192416 | 2019-10-01 |
| K191781 | 2019-08-06 |
| K181171 | 2019-04-02 |
| K183136 | 2019-01-30 |
| K181761 | 2018-12-26 |
| K182048 | 2018-12-07 |
| K161830 | 2016-10-26 |
| K161192 | 2016-07-08 |
| K131884 | 2013-08-22 |
| K130899 | 2013-05-01 |
| K123392 | 2013-03-04 |
| K113556 | 2012-02-17 |
| K101296 | 2010-07-30 |
| K093846 | 2010-02-04 |
| K081860 | 2008-09-26 |
| K073567 | 2008-03-13 |
| K071535 | 2007-11-19 |
| K040803 | 2004-04-29 |
| K030724 | 2003-06-03 |
| K972690 | 1997-10-15 |
| K971752 | 1997-07-30 |
| K955877 | 1996-10-08 |
| K944601 | 1995-01-12 |
| K915222 | 1993-06-22 |
| K914676 | 1992-01-13 |
| K905739 | 1991-03-07 |
Recalls
31 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-03-24 | Class II | Under Investigation by firm | The associated product labeling does not adequately provide compatibility information for use of the 22.2 mm Diameter Ceramic Femoral Heads with cobalt-chrome femoral stems or stainless-steel femoral stems. | 215 units | |
| 2025-03-24 | Class II | Under Investigation by firm | The associated product labeling does not adequately provide compatibility information for use of the 22.2 mm Diameter Ceramic Femoral Heads with cobalt-chrome femoral stems or stainless-steel femoral stems. | 167 units | |
| 2025-03-24 | Class II | Under Investigation by firm | The associated product labeling does not adequately provide compatibility information for use of the 22.2 mm Diameter Ceramic Femoral Heads with cobalt-chrome femoral stems or stainless-steel femoral stems. | 416 units | |
| 2025-03-24 | Class II | Under Investigation by firm | The associated product labeling does not adequately provide compatibility information for use of the 22.2 mm Diameter Ceramic Femoral Heads with cobalt-chrome femoral stems or stainless-steel femoral stems. | 160 units | |
| 2025-03-24 | Class II | Under Investigation by firm | The associated product labeling does not adequately provide compatibility information for use of the 22.2 mm Diameter Ceramic Femoral Heads with cobalt-chrome femoral stems or stainless-steel femoral stems. | 158 units | |
| 2025-02-12 | Class II | Under Investigation by firm | There is a potential design issue with the Z1 Offset Stem Inserter leading to fracturing of the distal tip. | 35 units | |
| 2024-08-08 | Class II | Under Investigation by firm | Mislabeled: Incorrect sleeve in the packaging. The outer packaging is labeled as a standard neck sleeve, however, the product within the box is a -6mm neck sleeve, and vice versa. The neck of the sleeve can be identified by the device etchi | 69 units | |
| 2024-08-08 | Class II | Under Investigation by firm | Mislabeled: Incorrect sleeve in the packaging. The outer packaging is labeled as a standard neck sleeve, however, the product within the box is a -6mm neck sleeve, and vice versa. The neck of the sleeve can be identified by the device etchi | 58 units | |
| 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| 2018-10-31 | Class II | Process control | Mislabeled Labeled Avenir Mller Stem size 1, the stem inside the packaging is an Avenir Mller Stem size 2. | 13 units | 2020-04-01 |
| 2018-03-29 | Class II | Under Investigation by firm | There is a potential for debris in the hole on the superior lateral aspect of the device as a result of machining which may not have been adequately removed during the subsequent cleaning process. | 1,145 distribution events. Note that this product is lot con | 2019-12-17 |
| 2018-02-28 | Class II | Error in labeling | A potential commingle that could result in the product in the package not matching the product on the outer label. | 2019-10-25 | |
| 2018-02-28 | Class II | Error in labeling | A potential commingle that could result in the product in the package not matching the product on the outer label. | 2019-10-25 | |
| 2017-02-28 | Class II | Packaging | Zimmer Biomet Inc. initiated a field action on 02/28/2017 for sterile-packaged implants packaged in two different package configurations due to packaging design verification test failures. | 9867 | 2018-02-27 |
| 2016-06-30 | Class II | Labeling mix-ups | Product mix-up. The Avenir Mller Stem 6 lateral uncemented might be placed in the packaging of the Avenir Mller Stem 4 standard uncemented and vice versa. Potential for delay in surgery, and/or potential for use of incorrect implant which | 2 | 2017-03-27 |
| 2015-02-05 | Class II | Process control | PMMA coating does not meet specifications. Area of the stem may be missing PMMA coating. | 1 unit | 2015-09-23 |
| 2014-12-17 | Class II | Package design/selection | Potential compromise of the inner sterile tray. If a compromised tray is detected, a delay in surgery may result. If undetected breach in both the inner and outer trays were to occur, and there is contamination present, a periprosthetic inf | 10340 | 2015-09-23 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 2010 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 1355 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 88 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 56 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 87 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 30 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 2544 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 13 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 58 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 5 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 18 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Wintetthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 126 | 2014-04-16 |
| 2009-05-29 | Not classified | Packaging process control | The corner tab of the inner compartment lid was not folded under before the outer lid was sealed, resulting in lack of assurance of sterility. | 147 of both products | 2009-12-22 |
| 2008-06-11 | Not classified | Device Design | When used with cobalt/chromium hip stems, the average test values for ceramic head bursting falls below the guidance document limits if the taper is made by casting instead of by forging. | 49,474 of all products | 2009-11-10 |
| 2008-06-11 | Not classified | Device Design | When used with cobalt/chromium hip stems, the average test values for ceramic head bursting falls below the guidance document limits if the taper is made by casting instead of by forging. | 49,474 of all products | 2009-11-10 |
| 2008-06-11 | Not classified | Device Design | When used with cobalt/chromium hip stems, the average test values for ceramic head bursting falls below the guidance document limits if the taper is made by casting instead of by forging. | 49,474 of all products | 2009-11-10 |
| 2008-06-11 | Not classified | Device Design | When used with cobalt/chromium hip stems, the average test values for ceramic head bursting falls below the guidance document limits if the taper is made by casting instead of by forging. | 49,474 of all products | 2009-11-10 |
| 2008-06-11 | Not classified | Device Design | When used with cobalt/chromium hip stems, the average test values for ceramic head bursting falls below the guidance document limits if the taper is made by casting instead of by forging. | 49,474 of all products | 2009-11-10 |
| 2008-06-11 | Not classified | Device Design | When used with cobalt/chromium hip stems, the average test values for ceramic head bursting falls below the guidance document limits if the taper is made by casting instead of by forging. | 49,474 of all products | 2009-11-10 |
| 2003-01-06 | Not classified | Other | Compression test results are not in accordance with device approval submission | 2003-12-04 | |
| 2003-01-06 | Not classified | Other | Compression test results are not in accordance with device approval submission | 2003-12-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.