Implant Partners

Poly 15DG Liner 36MM GRP E A-Class® Implant Partners™

Registry build 21.09.26
15manufacturers in China registered for this device type
35catalogue numbers in this listing
12510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LZO
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 15. All 15 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

Record

Regulatory record for Implant Partners
Listed by Microport Orthopedics Inc., United States
FDA product code LZO
Device type Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Contract manufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-10-23
Record revised 2018-03-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Sizes Lumen/inner diameter 28 to 36 mm; outer diameter 46 to 66 mm

Catalogue Numbers

Catalogue numbers for Implant Partners
Catalogue number Size Status
PRTLE023WD In distribution
PRTLS027WD In distribution
DLXPLE36WD Lumen/Inner Diameter 36 mm In distribution
DSPCGG60WD Outer Diameter 60 mm In distribution
PRTLS025WD In distribution
DLXPGE36WD Lumen/Inner Diameter 36 mm In distribution
DLXPLD36WD Lumen/Inner Diameter 36 mm In distribution
DLXPGF36WD Lumen/Inner Diameter 36 mm In distribution
PRTLS029WD In distribution
DLXPLG36WD Lumen/Inner Diameter 36 mm In distribution
DSPCGC50WD Outer Diameter 50 mm In distribution
PRTLS030WD In distribution
DLXPLF36WD Lumen/Inner Diameter 36 mm In distribution
PRTLE031WD In distribution
PRTLE025WD In distribution
DSPCGH64WD Outer Diameter 64 mm In distribution
DSPCGE54WD Outer Diameter 54 mm In distribution
PRTLS021WD In distribution
DSPCGB48WD Outer Diameter 48 mm In distribution
DSPCGF56WD Outer Diameter 56 mm In distribution
DSPCGG58WD Outer Diameter 58 mm In distribution
DLXPLH36WD Lumen/Inner Diameter 36 mm In distribution
DSPCGG62WD Outer Diameter 62 mm In distribution
DLXPGC32WD Lumen/Inner Diameter 32 mm In distribution
PRTLE027WD In distribution
DSPCGD52WD Outer Diameter 52 mm In distribution
DLXPLC32WD Lumen/Inner Diameter 32 mm In distribution
DLXPGD36WD Lumen/Inner Diameter 36 mm In distribution
DSPCGB46WD Outer Diameter 46 mm In distribution
DLXPGB28WD Lumen/Inner Diameter 28 mm In distribution
DSPCGH66WD Outer Diameter 66 mm In distribution
PRTLS023WD In distribution
PRTLE021WD In distribution
DLXPLB28WD Lumen/Inner Diameter 28 mm In distribution
PRTLE029WD In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Libertas Maxx Orthopedics Inc. 1,832
Redapt Smith & Nephew, Inc. 326
Bencox Hip System Corentec Co., Ltd. 295
M-Vizion Femoral Revision System Medacta International SA 289
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Zimmer, Inc. 280
Profemur® Microport Orthopedics Inc. 229
DJO Surgical Encore Medical, L.P. 162
Instrument Howmedica Osteonics Corp 152
Alteon Exactech, Inc. 151
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Exactech, Inc. 136
Resolve Modular Revision Hip Stem United Orthopedic Corp. 136
Wagner SL Revision® Zimmer, Inc. 133

Showing 12 of 691. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250444 2025-05-15
K240452 2024-04-12
K200007 2020-04-25
K191632 2019-10-07
K181598 2018-09-14
K173776 2018-07-06
K171181 2017-08-28
K150133 2015-04-20
K150302 2015-04-10
K141235 2014-09-12
K140676 2014-05-30
K140043 2014-04-03

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-11-17 Class II Process control The recall is being initiated because all broach handles in the affected lot had the same non-conformity with the connection feature. The broach handles may have machining issues that do not allow the handle to properly mate with an associa 20 units 2018-08-18
2016-06-21 Class III Device Design Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm 108,362 units 2017-07-01
2016-06-21 Class III Device Design Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm 68,221 units 2017-07-01
2016-06-21 Class III Device Design Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm 68,199 units 2017-07-01
2016-06-21 Class III Device Design Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm 22 units 2017-07-01
2016-06-21 Class III Device Design Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm 500 units 2017-07-01
2016-06-21 Class III Device Design Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm 6,250 units 2017-07-01
2016-06-21 Class III Device Design Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm 5,009 units 2017-07-01

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer