Integral 180 HIP System
7 catalogue numbers from 166019, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented. 15 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (8), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 15. All 15 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | LZO |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3353 |
| 510(k) | K030055 |
| Record published | 2015-10-24 |
| Record revised | 2025-05-30 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 166019 | 19 SIZE 180 MM TYPE1 TAPER | In distribution |
| 11-166011 | 11 SIZE 180 MM TYPE1 TAPER | In distribution |
| 166014 | 14 SIZE 180 MM TYPE1 TAPER | In distribution |
| 11-166014 | 14 SIZE 180 MM TYPE1 TAPER | In distribution |
| 11-166013 | 13 SIZE 180 MM TYPE1 TAPER | In distribution |
| 11-166019 | 19 SIZE 180 MM TYPE1 TAPER | In distribution |
| 11-166018 | 18 SIZE 180 MM TYPE1 TAPER | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Libertas | Maxx Orthopedics Inc. | 1,832 |
| Redapt | Smith & Nephew, Inc. | 326 |
| Bencox Hip System | Corentec Co., Ltd. | 295 |
| M-Vizion Femoral Revision System | Medacta International SA | 289 |
| Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Zimmer, Inc. | 280 |
| Profemur® | Microport Orthopedics Inc. | 229 |
| DJO Surgical | Encore Medical, L.P. | 162 |
| Instrument | Howmedica Osteonics Corp | 152 |
| Alteon | Exactech, Inc. | 151 |
| Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Exactech, Inc. | 136 |
| Resolve Modular Revision Hip Stem | United Orthopedic Corp. | 136 |
| Wagner SL Revision® | Zimmer, Inc. | 133 |
Showing 12 of 691. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K200196 | 2020-12-08 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2019-08-21 | Class II | Environmental control | Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. | 219988 units (total) | 2021-07-21 |
| Biomet, Inc. | 510(k) number | 2015-04-16 | Class III | Labeling mix-ups | Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes. | 1315 | 2016-05-16 |
| Biomet, Inc. | 510(k) number | 2015-01-09 | Class II | Packaging process control | Biomet recalled the Mallory Head 4 Finned Acetabular Shell 50mm (Lot 364600) and Ringloc + Acetabular Shell Limited Hole Finned 52 mm (Lot 427840) following a mix up in packaging with the two. | 17 | 2015-10-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.