MiniMAX Stems

miniMAX Stem - Size 6 Right

Registry build 21.09.26
15manufacturers in China registered for this device type
20catalogue numbers in this listing
10510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LZO
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 15. All 15 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

Record

Regulatory record for MiniMAX Stems
Listed by Medacta International SA, Switzerland
FDA product code LZO
Device type Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Specification developer, Repacker / relabeller, Private-label distributor, Complaint-file establishment, Manufacturer, Exporter
510(k) K170845
Record published 2017-08-22
Record revised 2026-01-21 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for MiniMAX Stems
Catalogue number Size Status
01.13.101L In distribution
01.13.106R In distribution
01.13.100R In distribution
01.13.102R In distribution
01.13.108R In distribution
01.13.109L In distribution
01.13.101R In distribution
01.13.102L In distribution
01.13.107R In distribution
01.13.103R In distribution
01.13.105L In distribution
01.13.103L In distribution
01.13.109R In distribution
01.13.104R In distribution
01.13.100L In distribution
01.13.107L In distribution
01.13.106L In distribution
01.13.105R In distribution
01.13.108L In distribution
01.13.104L In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Libertas Maxx Orthopedics Inc. 1,832
Redapt Smith & Nephew, Inc. 326
Bencox Hip System Corentec Co., Ltd. 295
M-Vizion Femoral Revision System Medacta International SA 289
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Zimmer, Inc. 280
Profemur® Microport Orthopedics Inc. 229
DJO Surgical Encore Medical, L.P. 162
Instrument Howmedica Osteonics Corp 152
Alteon Exactech, Inc. 151
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Exactech, Inc. 136
Resolve Modular Revision Hip Stem United Orthopedic Corp. 136
Wagner SL Revision® Zimmer, Inc. 133

Showing 12 of 691. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K160289 2016-05-20
K151531 2015-10-30
K131518 2013-11-04
K131458 2013-10-01
K122911 2012-10-19
K122641 2012-09-28
K121011 2012-06-08
K120531 2012-04-18
K112115 2011-10-07
K103352 2011-02-11

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of MiniMAX Stems
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Medacta Usa Inc 510(k) number 2017-11-15 Class II Package design/selection Complaint monitoring noted a trend of packaging being breached for the MiniMAX Stem. 837 units 2019-03-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker