Primo™ Acetabular System

Cementless Acetabular Shell, Full Hole; Porous Plasma Spray + HA Coating; 70mm Outer Diameter, Size L Liner

Registry build 21.09.26
15manufacturers in China registered for this device type
56catalogue numbers in this listing
4510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (3), Zhejiang (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LZO
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 15. All 15 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

Record

Regulatory record for Primo™ Acetabular System
Listed by B-ONE Ortho, Corp., United States
FDA product code LZO
Device type Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Specification developer, Manufacturer
Record published 2026-02-11

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Primo™ Acetabular System
Catalogue number Size Status
881906166L In distribution
881322501E In distribution
881312701L In distribution
881322561H In distribution
881321561I In distribution
881321501F In distribution
881906172L In distribution
881321661L In distribution
881322581I In distribution
881321601K In distribution
881322461D In distribution
881321581J In distribution
881321461D In distribution
881322641L In distribution
881321561H In distribution
881321621L In distribution
881322541H In distribution
881321581I In distribution
881322701L In distribution
881322621K In distribution
881321541H In distribution
881321541G In distribution
881322721L In distribution
881322561I In distribution
881322481D In distribution
881322621L In distribution
881322661L In distribution
881321481D In distribution
881321601J In distribution
881321521G In distribution
881322521G In distribution
881321681L In distribution
881321501E In distribution
881322601K In distribution
881312681L In distribution
881321641L In distribution
881321481E In distribution
881321721L In distribution
881322481E In distribution
881321701L In distribution
881906168L In distribution
881312661L In distribution
881906170L In distribution
881322581J In distribution
881322681L In distribution
881322521F In distribution
881322461C In distribution
881322601J In distribution
881322501F In distribution
881321441C In distribution
881321521F In distribution
881322541G In distribution
881322441C In distribution
881312721L In distribution
881321461C In distribution
881321621K In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Libertas Maxx Orthopedics Inc. 1,832
Redapt Smith & Nephew, Inc. 326
Bencox Hip System Corentec Co., Ltd. 295
M-Vizion Femoral Revision System Medacta International SA 289
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Zimmer, Inc. 280
Profemur® Microport Orthopedics Inc. 229
DJO Surgical Encore Medical, L.P. 162
Instrument Howmedica Osteonics Corp 152
Alteon Exactech, Inc. 151
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Exactech, Inc. 136
Resolve Modular Revision Hip Stem United Orthopedic Corp. 136
Wagner SL Revision® Zimmer, Inc. 133

Showing 12 of 691. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K240528 2024-11-15
K202768 2021-04-01
K182705 2019-02-14
K173380 2018-08-30

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer