Prosthesis, Hip, Hemi-, Femoral, Metal Ball

MODULAR CATHCART FRACTURE HEAD HIP BALL 48mm OD +5mm

Registry build 21.09.26
5manufacturers in China registered for this device type
21catalogue numbers in this listing
1recall

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LZY
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Prosthesis, Hip, Hemi-, Femoral, Metal Ball
Listed by Depuy Orthopaedics, Inc., United States
FDA product code LZY
Device type Prosthesis, Hip, Hemi-, Femoral, Metal Ball
Device class Class 2
Regulation 21 CFR 888.3360
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K903084
Record published 2015-09-24
Record revised 2025-02-07 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Prosthesis, Hip, Hemi-, Femoral, Metal Ball
Catalogue number Size Status
1363-48-000 In distribution
1363-49-000 In distribution
1363-58-000 In distribution
1363-53-000 In distribution
1363-56-000 In distribution
1363-14-000 In distribution
1363-51-000 In distribution
1363-42-000 In distribution
1363-52-000 In distribution
1363-10-000 In distribution
1363-47-000 In distribution
1363-12-000 In distribution
1363-44-000 In distribution
1363-50-000 In distribution
1363-60-000 In distribution
1363-08-000 In distribution
1363-45-000 In distribution
1363-43-000 In distribution
1363-46-000 In distribution
1363-41-000 In distribution
1363-54-000 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Endohead Medacta International SA 51
Quadra P femoral stems Medacta International SA 27
Tandem Smith & Nephew, Inc. 24
B-P Total HIP System Endotec, Inc. 20
Balance Microplasty HIP System Biomet Orthopedics 6
Prosthesis, Hip, Hemi-, Femoral, Metal Ball Smith & Nephew, Inc. 4
Sirius® Hip System Biomet Orthopedics 3
Taperloc Microplasty HIP System Biomet Orthopedics 3
Sirius Biomet Orthopedics 3
Balance HIP System Biomet Orthopedics 3
Cureguard Jiangsu Cureguard Glove Co., Ltd. 1
Masterloc Femoral Stems Medacta International SA 1

Showing 12 of 13. All products under Prosthesis, Hip, Hemi-, Femoral, Metal Ball

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Prosthesis, Hip, Hemi-, Femoral, Metal Ball
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Depuy Orthopaedics, Inc. 510(k) number 2022-05-18 Class II Labeling design The Cathcart Ball has an inherent +5mm offset which is not currently specified in its Instructions for Use or Surgical Technique Guide. The STG has been updated to reflect the clarification that the +5mm offset should be taken into consider 3488

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer