Crossft
The FDA summary names the CrossFT Knotless Biocomposite Suture Anchor with Disposable Driver as a sterile, single-use device. The anchors are preloaded on a disposable driver and are…
The FDA summary names the CrossFT Knotless Biocomposite Suture Anchor with Disposable Driver as a sterile, single-use device.
The anchors are preloaded on a disposable driver and are intended to reattach soft tissue to bone in orthopedic surgery, including arthroscopic or open procedures.
Listed Item
CrossFT Knotless Biocomposite 4.0 mm Suture Anchor with one 2 mm Hi-Fi Tape (White/Black)
Anchor Details
The filing says the anchor is made from polylactide copolymer and beta-tricalcium phosphate, and is available in three sizes and nine configurations.
Who Else Makes It
All of them in Shanghai.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
Record
| Listed by | ConMed Corporation, United States |
|---|---|
| FDA product code | MAI |
| Device type | Fastener, Fixation, Biodegradable, Soft Tissue |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K170501 |
| Record published | 2017-04-03 |
| Record revised | 2024-04-19 (version 7) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: KEEP DRY; Storage environment temperature up to 40 °C; Storage environment temperature up to 104 °F |
| Distribution end date | 2024-04-18 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| CFKB-475S | 4.75 MM | In distribution |
| CFKB-40 | 4.0 MM | In distribution |
| CFKB-55S | 4.75 MM | In distribution |
| CFKB-40TB | 4.0 MM | Withdrawn |
| CFKB-40TA | 4.0 MM | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arthrex® | Arthrex, Inc. | 545 |
| Fix2Lock | Osteonic Co., Ltd. | 118 |
| Delta | Stryker Leibinger Gmbh & Co. KG | 110 |
| Reunite Screw System | Biomet Orthopedics | 85 |
| ComposiTCP | S.B.M | 61 |
| ActivaScrew™ Interference | Bioretec Ltd. | 54 |
| Ligafix | S.B.M | 40 |
| Twinfix | Smith & Nephew, Inc. | 28 |
| Biosure | Smith & Nephew, Inc. | 27 |
| TorqLoc Interference | Bioretec Ltd. | 27 |
| FiberFIX | Nanova BIO Materials Inc | 25 |
| AlphaVent | Stryker GmbH | 23 |
Showing 12 of 176. All products under Fastener, Fixation, Biodegradable, Soft Tissue
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252946 | 2025-10-15 |
| K240090 | 2024-03-05 |
| K180763 | 2018-07-19 |
| K171592 | 2017-08-29 |
| K170501 | 2017-03-17 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-07-14 | Class II | Labeling design | Suture anchor may contain incorrect patient implant card which may result in incorrect device identification and traceability. | 2 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.