SeaSpine Spacer System – Redondo™
Redondo Implant, 30mm x 24mm x 14mm, 15 Deg Lordotic
Who Else Makes It
Concentrated in Jiangsu (6), Shandong (2), Shanghai (2). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Jiangsu Ideal Medical Science & Technology Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 7 |
| Zhisu Health Tech Jiaxing Co., Ltd. | Tongxiang | Zhejiang | Contract manufacturer | 4 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Shanghai Reach Medical Instrument Co., Ltd. | Shanghai | Shanghai | Manufacturer | 30 |
| Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 25 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
Showing 12 of 14. All 14 manufacturers in China registered for Intervertebral Fusion Device With Bone Graft, Lumbar
Record
| Listed by | Seaspine Orthopedics Corporation, United States |
|---|---|
| FDA product code | MAX |
| Device type | Intervertebral Fusion Device With Bone Graft, Lumbar |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3080 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K082310 |
| Record published | 2015-09-24 |
| Record revised | 2025-10-24 (version 9) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Distribution end date | 2016-09-02 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 36-2622 | 26mm x 24mm x 22mm, 5° | In distribution |
| 93-6422 | 38mm x 26mm x 22mm, 8° | In distribution |
| 36-3820 | 38mm x 26mm x 20mm, 8° | In distribution |
| 93-6276 | 34mm x 24mm x 12mm, 12° | In distribution |
| 93-6131 | 30mm x 24mm x 22mm | In distribution |
| 93-6612 | 26mm x 24mm x 12mm, 8° | In distribution |
| 93-6436 | 38mm x 26mm x 22mm, 12° | In distribution |
| 93-6223 | 30mm x 24mm x 20mm, 10° | In distribution |
| 36-3410 | 34mm x 24mm x 10mm, 8° | In distribution |
| 36-3010 | 30mm x 24mm x 10mm, 5° | In distribution |
| 36-3814 | 38mm x 26mm x 14mm, 8° | In distribution |
| 93-6380 | 30mm x 24mm x 10mm, 5° | In distribution |
| 93-6620 | 26mm x 24mm x 20mm, 8° | In distribution |
| 36-3420 | 34mm x 24mm x 20mm, 8° | In distribution |
| 93-6056 | 30mm x 24mm x 16mm | In distribution |
| 93-6384 | 30mm x 24mm x 14mm, 5° | In distribution |
| 36-3016 | 30mm x 24mm x 16mm, 5° | In distribution |
| 93-6232 | 34mm x 24mm x 12mm, 8° | In distribution |
| 93-6060 | 30mm x 24mm x 20mm | In distribution |
| 36-3512 | 34mm x 24mm x 12mm, 12° | In distribution |
| 93-6284 | 34mm x 24mm x 20mm, 12° | In distribution |
| 36-3022 | 30mm x 24mm x 22mm, 5° | In distribution |
| 93-6264 | 38mm x 26mm x 14mm, 12° | In distribution |
| 93-6610 | 26mm x 24mm x 10mm, 8° | In distribution |
| 93-6432 | 38mm x 26mm x 18mm, 12° | In distribution |
| 93-6388 | 30mm x 24mm x 18mm, 5° | In distribution |
| 93-6016 | 30mm x 24mm x 16mm | In distribution |
| 93-6262 | 38mm x 26mm x 12mm, 12° | In distribution |
| 93-6126 | 30mm x 24mm x 17mm | In distribution |
| 93-6020 | 30mm x 24mm x 10mm | In distribution |
| 93-6012 | 30mm x 24mm x 12mm | In distribution |
| 93-6282 | 34mm x 24mm x 18mm, 12° | In distribution |
| 93-6222 | 30mm x 24mm x 18mm, 10° | In distribution |
| 93-6245 | 34mm x 24mm x 10mm, 12° | In distribution |
| 93-6221 | 30mm x 24mm x 16mm, 10° | In distribution |
| 93-6128 | 30mm x 24mm x 19mm | In distribution |
| 93-6418 | 38mm x 26mm x 18mm, 8° | In distribution |
| 36-3916 | 38mm x 26mm x 16mm, 12° | In distribution |
| 36-2612 | 26mm x 24mm x 12mm, 5° | In distribution |
| 36-1514 | 30mm x 24mm x 14mm, 15° | In distribution |
| 93-6241 | 34mm x 24mm x 16mm, 8° | In distribution |
| 93-6382 | 30mm x 24mm x 12mm, 5° | In distribution |
| 36-2614 | 26mm x 24mm x 14mm, 5° | In distribution |
| 93-6260 | 38mm x 26mm x 10mm, 12° | In distribution |
| 93-6050 | 30mm x 24mm x 10mm | In distribution |
| 93-6058 | 30mm x 24mm x 18mm | In distribution |
| 93-6227 | 30mm x 24mm x 16mm, 15° | In distribution |
| 93-6125 | 30mm x 24mm x 16mm | In distribution |
| 93-6274 | 34mm x 24mm x 10mm, 12° | In distribution |
| 93-6412 | 38mm x 26mm x 12mm, 8° | In distribution |
| 93-6410 | 38mm x 26mm x 10mm, 8° | In distribution |
| 93-6129 | 30mm x 24mm x 20mm | In distribution |
| 36-3822 | 38mm x 26mm x 22mm, 8° | In distribution |
| 36-3416 | 34mm x 24mm x 16mm, 8° | In distribution |
| 93-6253 | 34mm x 24mm x 18mm, 12° | In distribution |
| 93-6244 | 34mm x 24mm x 22mm, 8° | In distribution |
| 93-6120 | 30mm x 24mm x 11mm | In distribution |
| 93-6255 | 34mm x 24mm x 22mm, 12° | In distribution |
| 93-6231 | 34mm x 24mm x 10mm, 8° | In distribution |
| 36-1512 | 30mm x 24mm x 12mm, 15° | In distribution |
| 93-6018 | 30mm x 24mm x 18mm | In distribution |
| 93-6272 | 34mm x 24mm x 22mm, 8° | In distribution |
| 93-6268 | 34mm x 24mm x 18mm, 8° | In distribution |
| 93-6110 | 30mm x 24mm x 10mm | In distribution |
| 36-1018 | 30mm x 24mm x 18mm, 10° | In distribution |
| 93-6242 | 34mm x 24mm x 18mm, 8° | In distribution |
| 36-3012 | 30mm x 24mm x 12mm, 5° | In distribution |
| 93-6392 | 30mm x 24mm x 22mm, 5° | In distribution |
| 93-6220 | 30mm x 24mm x 14mm, 10° | In distribution |
| 93-6414 | 38mm x 26mm x 14mm, 8° | In distribution |
| 93-6434 | 38mm x 26mm x 20mm, 12° | In distribution |
| 93-6420 | 38mm x 26mm x 20mm, 8° | In distribution |
| 36-3516 | 34mm x 24mm x 16mm, 12° | In distribution |
| 36-2818 | 26mm x 24mm x 18mm, 8° | Withdrawn |
| 36-4210 | 30mm x 24mm x 10mm, 12° | Withdrawn |
| 36-4822 | 30mm x 24mm x 22mm, 8° | Withdrawn |
| 36-4816 | 30mm x 24mm x 16mm, 8° | Withdrawn |
| 36-4810 | 30mm x 24mm x 10mm, 8° | Withdrawn |
| 36-2822 | 26mm x 24mm x 22mm, 8° | Withdrawn |
| 36-4814 | 30mm x 24mm x 14mm, 8° | Withdrawn |
| 36-2212 | 26mm x 24mm x 12mm, 12° | Withdrawn |
| 36-4818 | 30mm x 24mm x 18mm, 8° | Withdrawn |
| 36-2222 | 26mm x 24mm x 22mm, 12° | Withdrawn |
| 36-1020 | 30mm x 24mm x 20mm, 10° | Withdrawn |
| 36-4212 | 30mm x 24mm x 12mm, 12° | Withdrawn |
| 36-2814 | 26mm x 24mm x 14mm, 8° | Withdrawn |
| 36-2812 | 26mm x 24mm x 12mm, 8° | Withdrawn |
| 36-2820 | 26mm x 24mm x 20mm, 8° | Withdrawn |
| 36-4218 | 30mm x 24mm x 18mm, 12° | Withdrawn |
| 36-4216 | 30mm x 24mm x 16mm, 12° | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Peridot Intervertebral body fusion system | Gbs Commonwealth Co., Ltd. | 10,850 |
| Yellowstone | Summit Spine | 6,654 |
| CoRoent | Nuvasive, Inc. | 5,690 |
| Zavation | Zavation | 2,554 |
| Anyplus II Spinal Fixation System | GS Medical Co., Ltd. | 2,533 |
| Talos® IBF | Meditech Spine, LLC | 2,163 |
| Peridot-PT Intervertebral body fusion system | Gbs Commonwealth Co., Ltd. | 1,956 |
| TirboLOX-L Lumbar Ibfd | Captiva Spine, Inc. | 1,926 |
| Endoskeleton® TL | Titan Spine, LLC | 1,896 |
| Evos Lumbar Interbody System | Cutting Edge Spine | 1,871 |
| Epiphany | Pantheon Spinal LLC | 1,507 |
| LnK Lumbar Interbody Fusion Cage System | L&K Biomed Co., Ltd. | 1,506 |
Showing 12 of 1,958. All products under Intervertebral Fusion Device With Bone Graft, Lumbar
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253420 | 2026-07-01 |
| K241466 | 2024-06-20 |
| K240566 | 2024-04-26 |
| K233694 | 2024-01-12 |
| K222732 | 2022-11-07 |
| K220711 | 2022-05-10 |
| K213420 | 2022-05-04 |
| K212540 | 2021-09-10 |
| K210497 | 2021-07-07 |
| K210583 | 2021-06-02 |
| K201755 | 2020-12-15 |
| K201193 | 2020-11-25 |
| K200879 | 2020-06-10 |
| K193636 | 2020-04-24 |
| K193418 | 2020-03-13 |
| K192132 | 2019-12-03 |
| K181079 | 2018-07-18 |
| K173260 | 2017-12-04 |
| K173022 | 2017-10-26 |
| K162715 | 2016-10-28 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2025-08-06 | Class II | Device Design | Inserter, used as part of a system with an intervertebral body fusion device, may contribute to difficulty disengaging the implant or improper implant positioning, which may may lead to prolonged surgery, intraoperative revision, and may r | 74 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P000028 | 2004-06-18 | AFFINITY ANTERIOR CERVICAL CAGE SYSTEM | Medtronic Sofamor Danek USA, Inc. |
| P970015 | 2003-09-10 | LT-CAGE PEEK LUMBAR TAPERED FUSION DEVICE | Sofamor Danek |
| P980048 | 2001-04-20 | BAK/CERVICAL (BAK/C) INTERBODY FUSION SYSTEM | Sulzer Spine-Tech |
| P950019 | 1999-03-19 | RAY THREADED FUSION CAGE (TFC) DEVICE WITH INSTRUMENTATION | Stryker Spine |
| P950002 | 1997-06-30 | BAK INTERBODY FUSION SYSTEM | Zimmer Spine, Inc. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.