Stronghold® 3d Titanium Interbody Device System

Lumbar Titanium Cage - Lordotic 15° 9.5 mm x 25 mm x 11 mm

Registry build 21.09.26
14manufacturers in China registered for this device type
64catalogue numbers in this listing
14510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (6), Shandong (2), Shanghai (2). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MAX
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Jiangsu Ideal Medical Science & Technology Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7
Zhisu Health Tech Jiaxing Co., Ltd. Tongxiang Zhejiang Contract manufacturer 4
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Shanghai Reach Medical Instrument Co., Ltd. Shanghai Shanghai Manufacturer 30
Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. Changzhou Jiangsu Contract manufacturer 25
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14
Zhejiang Decans Medical Devices Co., Ltd. Jiaxing Zhejiang Manufacturer 10

Showing 12 of 14. All 14 manufacturers in China registered for Intervertebral Fusion Device With Bone Graft, Lumbar

Record

Regulatory record for Stronghold® 3D Titanium Interbody Device System
Listed by Spine Wave, Inc., United States
FDA product code MAX
Device type Intervertebral Fusion Device With Bone Graft, Lumbar
Device class Class 2
Regulation 21 CFR 888.3080
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K180990
Record published 2021-07-28
Record revised 2025-07-14 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Sizes Width 9.5 mm; length 22 to 30 mm; height 7 to 14 mm; angle 6 to 15 °

Catalogue Numbers

Catalogue numbers for Stronghold® 3D Titanium Interbody Device System
Catalogue number Size Status
SW19109-3014 Width 9.5 mm In distribution
SW19159-2511 Width 9.5 mm In distribution
SW19109-2210 Width 9.5 mm In distribution
SW19169-2511 Width 9.5 mm In distribution
SW19169-3007 Width 9.5 mm In distribution
SW19169-3010 Width 9.5 mm In distribution
SW19159-2512 Width 9.5 mm In distribution
SW19109-2512 Width 9.5 mm In distribution
SW19109-2209 Width 9.5 mm In distribution
SW19109-2513 Width 9.5 mm In distribution
SW19169-3012 Width 9.5 mm In distribution
SW19169-2514 Width 9.5 mm In distribution
SW19159-2208 Width 9.5 mm In distribution
SW19169-2210 Width 9.5 mm In distribution
SW19109-2509 Width 9.5 mm In distribution
SW19159-2207 Width 9.5 mm In distribution
SW19109-2207 Width 9.5 mm In distribution
SW19109-3010 Width 9.5 mm In distribution
SW19169-2509 Width 9.5 mm In distribution
SW19109-2514 Width 9.5 mm In distribution
SW19109-3013 Width 9.5 mm In distribution
SW19169-2207 Width 9.5 mm In distribution
SW19109-2214 Width 9.5 mm In distribution
SW19109-2508 Width 9.5 mm In distribution
SW19159-2510 Width 9.5 mm In distribution
SW19109-3009 Width 9.5 mm In distribution
SW19159-2513 Width 9.5 mm In distribution
SW19169-2513 Width 9.5 mm In distribution
SW19169-3009 Width 9.5 mm In distribution
SW19109-2510 Width 9.5 mm In distribution
SW19169-2508 Width 9.5 mm In distribution
SW19159-2509 Width 9.5 mm In distribution
SW19169-2211 Width 9.5 mm In distribution
SW19109-2208 Width 9.5 mm In distribution
SW19109-3012 Width 9.5 mm In distribution
SW19159-2214 Width 9.5 mm In distribution
SW19169-2510 Width 9.5 mm In distribution
SW19169-3014 Width 9.5 mm In distribution
SW19169-3011 Width 9.5 mm In distribution
SW19109-2507 Width 9.5 mm In distribution
SW19159-2508 Width 9.5 mm In distribution
SW19109-2511 Width 9.5 mm In distribution
SW19169-2213 Width 9.5 mm In distribution
SW19169-2212 Width 9.5 mm In distribution
SW19159-2211 Width 9.5 mm In distribution
SW19159-2507 Width 9.5 mm In distribution
SW19109-2213 Width 9.5 mm In distribution
SW19159-2209 Width 9.5 mm In distribution
SW19109-3008 Width 9.5 mm In distribution
SW19159-2210 Width 9.5 mm In distribution
SW19159-2212 Width 9.5 mm In distribution
SW19169-2507 Width 9.5 mm In distribution
SW19109-3007 Width 9.5 mm In distribution
SW19109-3011 Width 9.5 mm In distribution
SW19169-2209 Width 9.5 mm In distribution
SW19169-2208 Width 9.5 mm In distribution
SW19169-3013 Width 9.5 mm In distribution
SW19109-2212 Width 9.5 mm In distribution
SW19169-2214 Width 9.5 mm In distribution
SW19109-2211 Width 9.5 mm In distribution
SW19169-2512 Width 9.5 mm In distribution
SW19159-2213 Width 9.5 mm In distribution
SW19159-2514 Width 9.5 mm In distribution
SW19169-3008 Width 9.5 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Peridot Intervertebral body fusion system Gbs Commonwealth Co., Ltd. 10,850
Yellowstone Summit Spine 6,654
CoRoent Nuvasive, Inc. 5,690
Zavation Zavation 2,554
Anyplus II Spinal Fixation System GS Medical Co., Ltd. 2,533
Talos® IBF Meditech Spine, LLC 2,163
Peridot-PT Intervertebral body fusion system Gbs Commonwealth Co., Ltd. 1,956
TirboLOX-L Lumbar Ibfd Captiva Spine, Inc. 1,926
Endoskeleton® TL Titan Spine, LLC 1,896
Evos Lumbar Interbody System Cutting Edge Spine 1,871
Epiphany Pantheon Spinal LLC 1,507
LnK Lumbar Interbody Fusion Cage System L&K Biomed Co., Ltd. 1,506

Showing 12 of 1,958. All products under Intervertebral Fusion Device With Bone Graft, Lumbar

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K261159 2026-05-29
K243816 2025-06-27
K231275 2023-07-25
K163246 2017-04-06
K153222 2016-04-15
K152620 2016-01-15
K151581 2015-07-09
K150285 2015-03-05
K141980 2015-01-26
K142101 2014-10-23
K140007 2014-04-07
K132719 2013-10-04
K131071 2013-08-20
K123461 2013-04-11

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2013-05-14 Class II Component change control A component Superior endplate manufactured from a different polymer than specified 17 units 2014-02-10

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P000028 2004-06-18 AFFINITY ANTERIOR CERVICAL CAGE SYSTEM Medtronic Sofamor Danek USA, Inc.
P970015 2003-09-10 LT-CAGE PEEK LUMBAR TAPERED FUSION DEVICE Sofamor Danek
P980048 2001-04-20 BAK/CERVICAL (BAK/C) INTERBODY FUSION SYSTEM Sulzer Spine-Tech
P950019 1999-03-19 RAY THREADED FUSION CAGE (TFC) DEVICE WITH INSTRUMENTATION Stryker Spine
P950002 1997-06-30 BAK INTERBODY FUSION SYSTEM Zimmer Spine, Inc.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer