VBR-S Device

Trabecular Metal™ Vertebral Body Replacement-S

Registry build 21.09.26
14manufacturers in China registered for this device type
31catalogue numbers in this listing
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shandong (2), Shanghai (2). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MAX
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Jiangsu Ideal Medical Science & Technology Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7
Zhisu Health Tech Jiaxing Co., Ltd. Tongxiang Zhejiang Contract manufacturer 4
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Shanghai Reach Medical Instrument Co., Ltd. Shanghai Shanghai Manufacturer 30
Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. Changzhou Jiangsu Contract manufacturer 25
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14
Zhejiang Decans Medical Devices Co., Ltd. Jiaxing Zhejiang Manufacturer 10

Showing 12 of 14. All 14 manufacturers in China registered for Intervertebral Fusion Device With Bone Graft, Lumbar

Record

Regulatory record for VBR-S Device
Listed by Highridge Medical, LLC, United States
FDA product code MAX
Device type Intervertebral Fusion Device With Bone Graft, Lumbar
Device class Class 2
Regulation 21 CFR 888.3080
Establishment Specification developer, Manufacturer
Record published 2025-11-25

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for VBR-S Device
Catalogue number Size Status
06-115-00171 In distribution
06-115-10471 In distribution
06-115-00361 In distribution
06-115-00321 In distribution
06-115-00201 In distribution
06-115-00241 In distribution
06-115-00261 In distribution
06-115-00181 In distribution
06-115-10481 In distribution
06-115-10571 In distribution
06-115-10451 In distribution
06-115-00391 In distribution
06-115-00421 In distribution
06-115-10501 In distribution
06-115-10531 In distribution
06-115-00301 In distribution
06-115-00351 In distribution
06-115-10441 In distribution
06-115-10541 In distribution
06-115-10561 In distribution
06-115-10591 In distribution
06-115-00411 In distribution
06-115-10511 In distribution
06-115-00381 In distribution
06-115-10601 In distribution
06-115-00211 In distribution
06-115-00231 In distribution
06-115-00291 In distribution
06-115-00271 In distribution
06-115-10621 In distribution
06-115-00331 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Peridot Intervertebral body fusion system Gbs Commonwealth Co., Ltd. 10,850
Yellowstone Summit Spine 6,654
CoRoent Nuvasive, Inc. 5,690
Zavation Zavation 2,554
Anyplus II Spinal Fixation System GS Medical Co., Ltd. 2,533
Talos® IBF Meditech Spine, LLC 2,163
Peridot-PT Intervertebral body fusion system Gbs Commonwealth Co., Ltd. 1,956
TirboLOX-L Lumbar Ibfd Captiva Spine, Inc. 1,926
Endoskeleton® TL Titan Spine, LLC 1,896
Evos Lumbar Interbody System Cutting Edge Spine 1,871
Epiphany Pantheon Spinal LLC 1,507
LnK Lumbar Interbody Fusion Cage System L&K Biomed Co., Ltd. 1,506

Showing 12 of 1,958. All products under Intervertebral Fusion Device With Bone Graft, Lumbar

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-03-16 Class II Device Design Zimmer Biomet is recalling the Altius M-INI OCT Posterior Spinal Fixation System because the driver is unable to mate with the screw head tulip. 141 2018-07-30
2016-06-30 Class II Under Investigation by firm Zimmer Bioment Spine, Inc. announces a voluntary field action for the Zyston Transform Instrument Case and Zyston Transform Implant Kit because the locking mechanism on the implant is not functioning as intended. 5 2017-03-15
2016-06-30 Class II Under Investigation by firm Zimmer Bioment Spine, Inc. announces a voluntary field action for the Zyston Transform Instrument Case and Zyston Transform Implant Kit because the locking mechanism on the implant is not functioning as intended. 5 2017-03-15
2012-02-22 Class II Nonconforming Material/Component Biomet Spine, LLC is recalling the Timberline Cranial Caudal and Posterior Blades, 40-180mm due to oversize of the set screw hex feature. 213 2015-03-23
2011-03-09 Class II Device Design Biomet Spine, LLC. announces voluntary recall of Durango Anchored ALIF Plate due to the set screw component potentially becoming dislodged from the plate assembly. 120 2015-01-07

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P000028 2004-06-18 AFFINITY ANTERIOR CERVICAL CAGE SYSTEM Medtronic Sofamor Danek USA, Inc.
P970015 2003-09-10 LT-CAGE PEEK LUMBAR TAPERED FUSION DEVICE Sofamor Danek
P980048 2001-04-20 BAK/CERVICAL (BAK/C) INTERBODY FUSION SYSTEM Sulzer Spine-Tech
P950019 1999-03-19 RAY THREADED FUSION CAGE (TFC) DEVICE WITH INSTRUMENTATION Stryker Spine
P950002 1997-06-30 BAK INTERBODY FUSION SYSTEM Zimmer Spine, Inc.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer