Arcos

19 catalogue numbers from 31-300824, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish. 7 manufacturers in China are registered for this product code.

Registry build 21.09.26
7manufacturers in China registered for this device type
19catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (4), Shanghai (2), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MAY
Manufacturer City Province Registered as Device types
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Arcos
Listed by Biomet Orthopedics, United States
FDA product code MAY
Device type Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
Device class Class 2
Regulation 21 CFR 888.3353
510(k) K090757
Record published 2016-09-22
Record revised 2025-05-30 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Arcos
Catalogue number Size Status
31-300824 24MM X 150MM In distribution
31-311300 SIZE A 50MM STANDARD OFFSET In distribution
31-311342 SIZE B 80MM STANDARD In distribution
31-301416 16MM X 115MM In distribution
31-311305 SIZE E 60MM STANDARD OFFSET In distribution
31-300929 29MM X 190MM In distribution
31-300815 15MM X 150MM In distribution
31-300921 21MM X 190MM In distribution
31-311304 SIZE D 60MM STANDARD OFFSET In distribution
31-311301 SIZE A 60MM STANDARD OFFSET In distribution
31-301367 SIZE G In distribution
31-301326 SIZE F 70MM STANDARD OFFSET In distribution
31-311345 SIZE E 80MM STANDARD In distribution
31-300816 16MM X 150MM In distribution
31-311354 SIZE D 80MM In distribution
31-301306 SIZE F 60MM STANDARD OFFSET In distribution
31-311351 SIZE A 80MM In distribution
31-300917 17MM X 190MM In distribution
31-300820 20MM X 150MM In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Instrument Howmedica Osteonics Corp 136
Arcos Modular Revision System Biomet Orthopedics 48
Arcos Modular Revision Hip System Biomet Orthopedics 40
Ringloc HIP System Biomet Orthopedics 36
Restoration Howmedica Osteonics Corp 29
Echo® Bi-Metric® Hip System Biomet Orthopedics 18
Trident Howmedica Osteonics Corp 12
Arcos® STS™ Modular Revision System Biomet Orthopedics 10
Ringloc Ranawat / Burstein HIP System Biomet Orthopedics 10
OrthoMedFlex Orthomedflex LLC 10
Taperloc Complete Rasp/Provisional Biomet Orthopedics 9
Regenerex® Ringloc®+ Hip System Biomet Orthopedics 9

Showing 12 of 40. All products under Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Arcos
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2018-06-08 Class II Process control Two lots of the Echo BI-Metric Hip Stem and ARCOS Modular Revision Hip Stem may have been comingled. Potential health consequences include extension of surgery time to find a replacement component. 12 2020-04-14

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer