Comprehensive® Revision Shoulder System
Catalogue number 407344, listed by Biomet Orthopedics, United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (3), Zhejiang (1), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | MBF |
| Device type | Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3670 |
| 510(k) | K060692 |
| Record published | 2022-04-23 |
| Record revised | 2025-05-30 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 407344 | 4 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Shoulder Innovations Inset Reverse Total Shoulder | Shoulder Innovations, Inc | 181 |
| Shoulder Innovations Humeral Short Stem System | Shoulder Innovations, Inc | 87 |
| Comprehensive® Shoulder System | Biomet Orthopedics | 70 |
| BIO-Modular Shoulder System | Biomet Orthopedics | 41 |
| Shoulder Innovations InSet 95 Humeral Stem | Shoulder Innovations, Inc | 40 |
| Comprehensive® SRS Instrument | Biomet Orthopedics | 36 |
| Identity™ | Zimmer, Inc. | 29 |
| Comprehensive® SRS | Biomet Orthopedics | 25 |
| Inhance | Depuy (Ireland) | 25 |
| SMR Shoulder | Limacorporate | 20 |
| Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented | Synthes (U.S.A.) LP | 19 |
| BI-Angular System | Biomet Orthopedics | 16 |
Showing 12 of 71. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K112905 | 2012-05-24 |
Recalls Naming This Product
7 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Zimmer Orthopedics Manufacturing Limited-Galway | 510(k) number | 2025-03-03 | Class II | Nonconforming Material/Component | Five complaints received where surgeon was unable to remove and/or connect the inserter with the stem during surgery due to excess material remaining within the taper. Issue may lead to clinically significant extension of surgery to find a | 90 US; 136 OUS | |
| Biomet, Inc. | 510(k) number | 2020-02-17 | Class II | Under Investigation by firm | A 15mm Shoulder Mini Humeral Stem was misidentified as a 9mm Shoulder Mini Humeral Stem. | 14 units | 2022-05-31 |
| Biomet, Inc. | 510(k) number | 2018-10-10 | Class II | Under Investigation by firm | Zimmer Biomet is conducting a lot specific medical device recall for two lots of the Orthopedic Salvage System (OSS) and the Comprehensive Shoulder System. The investigation determined that the Mini Humeral Stem is potentially labeled as th | 3 total | 2020-04-28 |
| Biomet, Inc. | 510(k) number | 2017-12-08 | Class II | Under Investigation by firm | Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem | 12 | 2018-09-04 |
| Biomet, Inc. | 510(k) number | 2017-12-08 | Class II | Under Investigation by firm | Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem | 12 | 2018-09-04 |
| Biomet, Inc. | 510(k) number | 2017-06-05 | Class II | Labeling False and Misleading | Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. | 2018-03-06 | |
| Biomet, Inc. | 510(k) number | 2015-04-16 | Class III | Labeling mix-ups | Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes. | 2 | 2016-05-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.