Comprehensive® Revision Shoulder System

Catalogue number 407344, listed by Biomet Orthopedics, United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
1510(k) clearance

Who Else Makes It

Concentrated in Shanghai (3), Zhejiang (1), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MBF
Manufacturer City Province Registered as Device types
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Comprehensive® Revision Shoulder System
Listed by Biomet Orthopedics, United States
FDA product code MBF
Device type Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
Device class Class 2
Regulation 21 CFR 888.3670
510(k) K060692
Record published 2022-04-23
Record revised 2025-05-30 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Comprehensive® Revision Shoulder System
Catalogue number Size Status
407344 4 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Shoulder Innovations Inset Reverse Total Shoulder Shoulder Innovations, Inc 181
Shoulder Innovations Humeral Short Stem System Shoulder Innovations, Inc 87
Comprehensive® Shoulder System Biomet Orthopedics 70
BIO-Modular Shoulder System Biomet Orthopedics 41
Shoulder Innovations InSet 95 Humeral Stem Shoulder Innovations, Inc 40
Comprehensive® SRS Instrument Biomet Orthopedics 36
Identity™ Zimmer, Inc. 29
Comprehensive® SRS Biomet Orthopedics 25
Inhance Depuy (Ireland) 25
SMR Shoulder Limacorporate 20
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented Synthes (U.S.A.) LP 19
BI-Angular System Biomet Orthopedics 16

Showing 12 of 71. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K112905 2012-05-24

Recalls Naming This Product

7 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Comprehensive® Revision Shoulder System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer Orthopedics Manufacturing Limited-Galway 510(k) number 2025-03-03 Class II Nonconforming Material/Component Five complaints received where surgeon was unable to remove and/or connect the inserter with the stem during surgery due to excess material remaining within the taper. Issue may lead to clinically significant extension of surgery to find a 90 US; 136 OUS
Biomet, Inc. 510(k) number 2020-02-17 Class II Under Investigation by firm A 15mm Shoulder Mini Humeral Stem was misidentified as a 9mm Shoulder Mini Humeral Stem. 14 units 2022-05-31
Biomet, Inc. 510(k) number 2018-10-10 Class II Under Investigation by firm Zimmer Biomet is conducting a lot specific medical device recall for two lots of the Orthopedic Salvage System (OSS) and the Comprehensive Shoulder System. The investigation determined that the Mini Humeral Stem is potentially labeled as th 3 total 2020-04-28
Biomet, Inc. 510(k) number 2017-12-08 Class II Under Investigation by firm Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem 12 2018-09-04
Biomet, Inc. 510(k) number 2017-12-08 Class II Under Investigation by firm Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem 12 2018-09-04
Biomet, Inc. 510(k) number 2017-06-05 Class II Labeling False and Misleading Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. 2018-03-06
Biomet, Inc. 510(k) number 2015-04-16 Class III Labeling mix-ups Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes. 2 2016-05-16

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer