Hybrid® Glenoid Instrumentation
2 catalogue numbers from 406194, listed by Biomet Orthopedics, United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (3), Zhejiang (1), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | MBF |
| Device type | Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3670 |
| 510(k) | K060694 |
| Record published | 2022-04-23 |
| Record revised | 2025-05-30 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 406194 | In distribution | |
| 406172 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Shoulder Innovations Inset Reverse Total Shoulder | Shoulder Innovations, Inc | 181 |
| Shoulder Innovations Humeral Short Stem System | Shoulder Innovations, Inc | 87 |
| Comprehensive® Shoulder System | Biomet Orthopedics | 70 |
| BIO-Modular Shoulder System | Biomet Orthopedics | 41 |
| Shoulder Innovations InSet 95 Humeral Stem | Shoulder Innovations, Inc | 40 |
| Comprehensive® SRS Instrument | Biomet Orthopedics | 36 |
| Identity™ | Zimmer, Inc. | 29 |
| Comprehensive® SRS | Biomet Orthopedics | 25 |
| Inhance | Depuy (Ireland) | 25 |
| SMR Shoulder | Limacorporate | 20 |
| Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented | Synthes (U.S.A.) LP | 19 |
| BI-Angular System | Biomet Orthopedics | 16 |
Showing 12 of 71. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K112905 | 2012-05-24 |
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Zimmer Orthopedics Manufacturing Limited-Galway | 510(k) number | 2025-03-03 | Class II | Nonconforming Material/Component | Five complaints received where surgeon was unable to remove and/or connect the inserter with the stem during surgery due to excess material remaining within the taper. Issue may lead to clinically significant extension of surgery to find a | 90 US; 136 OUS | |
| Biomet, Inc. | 510(k) number | 2017-04-26 | Class II | Under Investigation by firm | Zimmer Biomet is conducting a voluntary recall for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped des | 16 | 2018-03-30 |
| Biomet, Inc. | 510(k) number | 2017-02-17 | Class II | Process design | Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components. | 28,253 in total | 2018-01-29 |
| Biomet, Inc. | 510(k) number | 2008-03-13 | Not classified | Device Design | The glenoid implant may not seat fully on the face of the natural glenoid due to inadequate measurement tolerances (tolerance stack-up) in the design of the cutter. Use of the instrument may lead to incomplete seating of the glenoid implan | 189 | 2008-10-15 |
| Biomet, Inc. | 510(k) number | 0012-12-06 | Class II | Nonconforming Material/Component | Biomet is recalling Part Number PT-113950 PT Hybrid Glenoid Post, following an investigation which identified that the male thread of the post may be oversized. This oversized condition can vary in degree and may lead to the following thre | 1050 | 2013-11-08 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.