Identity® Shoulder System

5 catalogue numbers from 11007614, listed by Zimmer, Inc., United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
5catalogue numbers in this listing
5510(k) clearances naming this product code

Who Else Makes It

Concentrated in Shanghai (3), Zhejiang (1), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MBF
Manufacturer City Province Registered as Device types
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Identity® Shoulder System
Listed by Zimmer, Inc., United States
FDA product code MBF
Device type Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
Device class Class 2
Regulation 21 CFR 888.3670
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K253592
Record published 2026-06-10

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Identity® Shoulder System
Catalogue number Size Status
11007614 Lateralized In distribution
110047327 +0 mm In distribution
11007619 Neutral In distribution
11007621 Neutral In distribution
11007790 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Shoulder Innovations Inset Reverse Total Shoulder Shoulder Innovations, Inc 181
Shoulder Innovations Humeral Short Stem System Shoulder Innovations, Inc 87
Comprehensive® Shoulder System Biomet Orthopedics 70
BIO-Modular Shoulder System Biomet Orthopedics 41
Shoulder Innovations InSet 95 Humeral Stem Shoulder Innovations, Inc 40
Comprehensive® SRS Instrument Biomet Orthopedics 36
Identity™ Zimmer, Inc. 29
Comprehensive® SRS Biomet Orthopedics 25
Inhance Depuy (Ireland) 25
SMR Shoulder Limacorporate 20
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented Synthes (U.S.A.) LP 19
BI-Angular System Biomet Orthopedics 16

Showing 12 of 71. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253592 2026-04-13
K251098 2025-08-11
K250848 2025-07-02
K240876 2024-06-12
K213856 2022-09-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer