Evolution Revision CCK System
26 catalogue numbers from EFPAN712, listed by Microport Orthopedics Inc., United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer. 12 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Microport Orthopedics Inc., United States |
|---|---|
| FDA product code | MBH |
| Device type | Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3565 |
| Establishment | Contract manufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2018-04-23 |
| Record revised | 2023-02-03 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| EFPAN712 | Thickness 12 mm | In distribution |
| EFDAN412 | Thickness 12 mm | In distribution |
| EFPAN508 | Thickness 8 mm | In distribution |
| EFPAN412 | Thickness 12 mm | In distribution |
| EFPAN408 | Thickness 8 mm | In distribution |
| EFDAN708 | Thickness 8 mm | In distribution |
| EFPAN704 | Thickness 4 mm | In distribution |
| EFDAN712 | Thickness 12 mm | In distribution |
| EFDAN304 | Thickness 4 mm | In distribution |
| EFDAN704 | Thickness 4 mm | In distribution |
| EFDAN408 | Thickness 8 mm | In distribution |
| EFDAN308 | Thickness 8 mm | In distribution |
| EFDAN608 | Thickness 8 mm | In distribution |
| EFPAN304 | Thickness 4 mm | In distribution |
| EFPAN504 | Thickness 4 mm | In distribution |
| EFPAN612 | Thickness 12 mm | In distribution |
| EFDAN312 | Thickness 12 mm | In distribution |
| EFDAN404 | Thickness 4 mm | In distribution |
| EFPAN608 | Thickness 8 mm | In distribution |
| EFDAN604 | Thickness 4 mm | In distribution |
| EFPAN512 | Thickness 12 mm | In distribution |
| EFDAN512 | Thickness 12 mm | In distribution |
| EFPAN404 | Thickness 4 mm | In distribution |
| EFDAN504 | Thickness 4 mm | In distribution |
| EFPAN708 | Thickness 8 mm | In distribution |
| EFDAN612 | Thickness 12 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prophecy | Microport Orthopedics Inc. | 4,272 |
| Triathlon | Howmedica Osteonics Corp | 712 |
| Instrument | Howmedica Osteonics Corp | 709 |
| Persona® Vivacit-E® | Zimmer, Inc. | 499 |
| Arthrex® | Arthrex, Inc. | 494 |
| Persona® | Zimmer, Inc. | 441 |
| Legion | Smith & Nephew, Inc. | 397 |
| U2 Total Knee System | United Orthopedic Corp. | 286 |
| Attune | Depuy (Ireland) | 234 |
| DJO Surgical | Encore Medical, L.P. | 191 |
| Vanguard XP Instrumentation | Biomet Orthopedics | 150 |
| Truliant® | Exactech, Inc. | 142 |
Showing 12 of 948. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253728 | 2026-08-21 |
| K233507 | 2024-01-18 |
| K213817 | 2022-01-05 |
| K180317 | 2018-05-04 |
| K170288 | 2017-06-15 |
| K152298 | 2015-11-16 |
| K143366 | 2015-01-21 |
| K140735 | 2014-08-29 |
Recalls
11 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2024-10-29 | Class II | Labeling Change Control | Femoral implant porous size 5 right primary and femoral implant non-porous size 6 left primary have correct markings on devices, but may have incorrect packaging. | 32 | |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 98 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 47 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 86 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 110 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 34 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 38 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 134 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 77 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 36 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 169 units | 2017-07-26 |
| 2016-06-21 | Class I | Use error | ADVANCE(R) HA Coated tibial bases are being recalled due to a higher than expected revision rate as a result of component loosening. | 60 units | 2017-07-26 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.