Maxim Knee System
92 catalogue numbers from 11-146150, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer. 12 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | MBH |
| Device type | Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3565 |
| 510(k) | K142933 |
| Record published | 2015-10-24 |
| Record revised | 2025-05-30 (version 5) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 11-146150 | 10MM 71/75MM | In distribution |
| 11-146722 | 22MM 59MM | In distribution |
| 11-146402 | 22MM 87/91MM | In distribution |
| 11-146136 | 16MM 63/67MM | In distribution |
| 145152 | 65MM | In distribution |
| 145171 | 60MM | In distribution |
| 11-146116 | 16MM 59MM | In distribution |
| 145412 | 65MM | In distribution |
| 11-146158 | 18MM 71/75MM | In distribution |
| 11-146572 | 12MM 79/83MM | In distribution |
| 11-146724 | 24MM 59MM | In distribution |
| 140050 | 55MM | In distribution |
| 11-146172 | 12MM 79/83MM | In distribution |
| 145413 | 70MM | In distribution |
| 140070 | 55MM | In distribution |
| 11-146176 | 16MM 79/83MM | In distribution |
| 11-146570 | 10MM 79/83MM | In distribution |
| 11-146112 | 12MM 59MM | In distribution |
| 11-146770 | 10MM 79/83MM | In distribution |
| 145412 | 65MM | In distribution |
| 11-146524 | 24MM 59MM | In distribution |
| 145172 | 65MM | In distribution |
| 11-146356 | 16MM 71/75MM | In distribution |
| 11-146792 | 12MM 87/91MM | In distribution |
| 11-146370 | 10MM 79/83MM | In distribution |
| 11-146716 | 16MM 59MM | In distribution |
| 11-146518 | 18MM 59MM | In distribution |
| 11-146382 | 22MM 79/83MM | In distribution |
| 11-146354 | 14MM 71/75MM | In distribution |
| 11-146396 | 16MM 87/91MM | In distribution |
| 11-146330 | 10MM 63/67MM | In distribution |
| 145174 | 75MM | In distribution |
| 11-146334 | 14MM 63/67MM | In distribution |
| 11-146338 | 18MM 63/67MM | In distribution |
| 11-146156 | 16MM 71/75MM | In distribution |
| 140055 | 80MM | In distribution |
| 11-146740 | 20MM 63/67MM | In distribution |
| 145198 | 55/60 MM | In distribution |
| 11-146564 | 24MM 71/75MM | In distribution |
| 11-146594 | 14MM 87/91MM | In distribution |
| 145411 | 60MM | In distribution |
| 145173 | 70MM | In distribution |
| 11-146510 | 10MM 59MM | In distribution |
| 11-146736 | 16MM 63/67MM | In distribution |
| 11-146762 | 22MM 71/75MM | In distribution |
| 11-146400 | 20MM 87/91MM | In distribution |
| 11-146362 | 22MM 71/75MM | In distribution |
| 11-146342 | 22MM 63/67MM | In distribution |
| 11-146538 | 18MM 63/67MM | In distribution |
| 11-146358 | 18MM 71/75MM | In distribution |
| 11-146800 | 20MM 87/91MM | In distribution |
| 11-146398 | 18MM 87/91MM | In distribution |
| 11-146778 | 18MM 79/83MM | In distribution |
| 140054 | 75MM | In distribution |
| 145414 | 75MM | In distribution |
| 145172 | 65MM | In distribution |
| 11-146404 | 24MM 87/91MM | In distribution |
| 11-146110 | 10MM 59MM | In distribution |
| 11-146794 | 14MM 87/91MM | In distribution |
| 11-146714 | 14MM 59MM | In distribution |
| 11-146604 | 24MM 87/91MM | In distribution |
| 140050 | 55MM | In distribution |
| 11-146174 | 14MM 79/83MM | In distribution |
| 145171 | 60MM | In distribution |
| 11-146514 | 14MM 59MM | In distribution |
| 11-146536 | 16MM 63/67MM | In distribution |
| 11-146752 | 12MM 71/75MM | In distribution |
| 11-146118 | 18MM 59MM | In distribution |
| 145151 | 60MM | In distribution |
| 11-146578 | 18MM 79/83MM | In distribution |
| 11-146802 | 22MM 87/91MM | In distribution |
| 145413 | 70MM | In distribution |
| 145430 | 55MM | In distribution |
| 11-146576 | 16MM 79/83MM | In distribution |
| 11-146734 | 14MM 63/67MM | In distribution |
| 11-146738 | 18MM 63/67MM | In distribution |
| 140070 | 55MM | In distribution |
| 11-146554 | 14MM 71/75MM | In distribution |
| 145433 | 70MM | In distribution |
| 140073 | 70MM | In distribution |
| 145434 | 75MM | In distribution |
| 11-146316 | 16MM 59MM | In distribution |
| 145175 | 80MM | In distribution |
| 11-146376 | 16MM 79/83MM | In distribution |
| 11-146758 | 18MM 71/75MM | In distribution |
| 140054 | 75MM | In distribution |
| 145152 | 65MM | In distribution |
| 145153 | 70MM | In distribution |
| 11-146732 | 12MM 63/67MM | In distribution |
| 11-146352 | 12MM 71/75MM | In distribution |
| 140053 | 70MM | In distribution |
| 11-146322 | 22MM 59MM | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prophecy | Microport Orthopedics Inc. | 4,272 |
| Triathlon | Howmedica Osteonics Corp | 712 |
| Instrument | Howmedica Osteonics Corp | 709 |
| Persona® Vivacit-E® | Zimmer, Inc. | 499 |
| Arthrex® | Arthrex, Inc. | 494 |
| Persona® | Zimmer, Inc. | 441 |
| Legion | Smith & Nephew, Inc. | 397 |
| U2 Total Knee System | United Orthopedic Corp. | 286 |
| Attune | Depuy (Ireland) | 234 |
| DJO Surgical | Encore Medical, L.P. | 191 |
| Vanguard XP Instrumentation | Biomet Orthopedics | 150 |
| Truliant® | Exactech, Inc. | 142 |
Showing 12 of 948. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
Recalls Naming This Product
10 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2018-12-21 | Class II | Under Investigation by firm | Vanguard Knee System Series-A Standard Patella a potential commingle that could result in the size of the implant not matching the size on the label. | 90 units | 2020-05-13 |
| Biomet, Inc. | 510(k) number | 2018-05-24 | Class II | Under Investigation by firm | Two lots of tibial bearings were commingled. There is a possibility that a 14mm tibial bearing is packaged in a box labeled as 12 mm tibial bearing and vice versa. This may lead to extension of surgery to find another implant. | 48 | 2020-04-07 |
| Biomet, Inc. | 510(k) number | 2018-05-18 | Class II | Under Investigation by firm | One lot of 75mm tibial tray is potentially etched and labeled as a 79 mm tibial tray. This may lead to delay in surgery, or immediate revision surgery to remove an incorrectly sized tibial component after it has been cemented. | 16 | 2020-03-31 |
| Biomet, Inc. | 510(k) number | 2018-05-11 | Class II | Under Investigation by firm | The label master file was errantly set up as a 63/37mm instead of a 63/67mm. There is no 63/37 size offered, and the product is laser marked with the correct size. | 169 | 2019-11-21 |
| Biomet, Inc. | 510(k) number | 2016-12-15 | Class II | Material/Component Contamination | Zimmer Biomet is conducting a medical device recall for ARCOS & TPRLC broaches and rasps due to potential alumina inclusions in the raw material batch used to produce the affected products. Inclusions contained within the finished product c | 26 | 2018-06-29 |
| Biomet, Inc. | 510(k) number | 2015-04-16 | Class III | Labeling mix-ups | Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes. | 1315 | 2016-05-16 |
| Biomet, Inc. | 510(k) number | 2011-03-03 | Not classified | Packaging process control | The firm is recalling the product due to the product’s packaging being labeled “I-Beam 75mm. Tibial Plate”, but the package actually contains the “Interlok 67mm. CR Tibial Plate”. | 8 | 2011-07-27 |
| Biomet, Inc. | 510(k) number | 2007-12-12 | Not classified | Packaging process control | Mislabeled as to size: Package labeled as containing a 67 mm tray actually contains a 75 mm tray and vice versa. | 8 | 2008-06-11 |
| Biomet, Inc. | 510(k) number | 2007-12-12 | Not classified | Packaging process control | Mislabeled as to size: Package labeled as containing a 67 mm tray actually contains a 75 mm tray and vice versa. | 8 | 2008-06-11 |
| Biomet, Inc. | 510(k) number | 2007-09-18 | Not classified | Labeling mix-ups | Mislabeled as to size: the package actaully contained a 71 mm tray. | 7 | 2008-06-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.