Nexgen® Trabecular Metal™
82 catalogue numbers from 00-5490-034-24, listed by Zimmer Trabecular Metal Technology, Inc., United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer. 12 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Zimmer Trabecular Metal Technology, Inc., United States |
|---|---|
| FDA product code | MBH |
| Device type | Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3565 |
| Establishment | Contract manufacturer, Manufacturer, Exporter |
| 510(k) | K120990 |
| Record published | 2015-09-24 |
| Record revised | 2026-07-09 (version 10) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 00-5490-034-24 | SIZE D, 20 MM AUGMENT | In distribution |
| 00-5448-004-27 | SIZE 4, 10 MM THICKNESS | In distribution |
| 00-5448-003-26 | SIZE 3, 5 MM THICKNESS | In distribution |
| 00-5448-004-29 | SIZE 4, 20 MM THICKNESS | In distribution |
| 00-5444-055-31 | SIZE 5, 31 MM x 31 MM, 7 DEGREE | In distribution |
| 00-5447-056-31 | SIZE 6, 31 MM X 31 MM, 0 DEGREE | In distribution |
| 00-5445-053-31 | SIZE 3, 31 MM x 31 MM, 0 DEGREE | In distribution |
| 00-5490-036-20 | SIZE F, 10 MM AUGMENT | In distribution |
| 00-5446-052-36 | SIZE 2, 36 MM X 31 MM, 7 DEGREE | In distribution |
| 00-5490-033-02 | SIZE C, 10 MM AUGMENT | In distribution |
| 00-5446-054-31 | SIZE 4, 31 MM X 31 MM, 7 DEGREE | In distribution |
| 00-5448-002-26 | SIZE 2, 5 MM THICKNESS | In distribution |
| 00-5490-033-20 | SIZE C, 10 MM AUGMENT | In distribution |
| 00-5446-053-31 | SIZE 3, 31 MM X 31 MM, 7 DEGREE | In distribution |
| 00-5444-056-41 | SIZE 6, 41 MM x 34 MM, 7 DEGREE | In distribution |
| 00-5448-005-40 | SIZE 5, 30 MM THICKNESS | In distribution |
| 00-5447-054-46 | SIZE 4, 46 MM X 34 MM, 0 DEGREE | In distribution |
| 00-5446-056-46 | SIZE 6, 46 MM X 34 MM, 7 DEGREE | In distribution |
| 00-5878-065-38 | SIZE 38 MM DIA., THICKNESS 10 MM | In distribution |
| 00-5448-006-26 | SIZE 6, 5 MM THICKNESS | In distribution |
| 00-5446-056-31 | SIZE 6, 31 MM X 31 MM, 7 DEGREE | In distribution |
| 00-5446-055-41 | SIZE 5, 41 MM X 34 MM, 7 DEGREE | In distribution |
| 00-5444-055-36 | SIZE 5, 36 MM x 31 MM, 7 DEGREE | In distribution |
| 00-5490-035-24 | SIZE E, 20 MM AUGMENT | In distribution |
| 00-5447-055-41 | SIZE 5, 41 MM X 34 MM, 0 DEGREE | In distribution |
| 00-5448-004-40 | SIZE 4, 30 MM THICKNESS | In distribution |
| 00-5448-003-37 | SIZE 3, 10 MM THICKNESS | In distribution |
| 00-5445-056-31 | SIZE 6, 31 MM x 31 MM, 0 DEGREE | In distribution |
| 00-5448-002-37 | SIZE 2, 10 MM THICKNESS | In distribution |
| 00-5878-065-32 | SIZE 32 MM DIA., THICKNESS 10 MM | In distribution |
| 00-5447-057-46 | SIZE 7, 46 MM X 34 MM, 0 DEGREE | In distribution |
| 00-5444-056-36 | SIZE 6, 36 MM x 31 MM, 7 DEGREE | In distribution |
| 00-5445-056-46 | SIZE 6, 46 MM x 34 MM, 0 DEGREE | In distribution |
| 00-5490-033-24 | SIZE C, 20 MM AUGMENT | In distribution |
| 00-5490-035-02 | SIZE E, 10 MM AUGMENT | In distribution |
| 00-5490-036-01 | SIZE F, 5 MM AUGMENT | In distribution |
| 00-5444-054-41 | SIZE 4, 41 MM x 34 MM, 7 DEGREE | In distribution |
| 00-5448-004-37 | SIZE 4, 10 MM THICKNESS | In distribution |
| 00-5448-005-37 | SIZE 5, 10 MM THICKNESS | In distribution |
| 00-5448-007-27 | SIZE 7, 10 MM THICKNESS | In distribution |
| 00-5490-034-02 | SIZE D, 10 MM AUGMENT | In distribution |
| 00-5445-054-31 | SIZE 4, 31 MM x 31 MM, 0 DEGREE | In distribution |
| 00-5446-055-31 | SIZE 5, 31 MM X 31 MM, 7 DEGREE | In distribution |
| 00-5448-005-30 | SIZE 5, 30 MM THICKNESS | In distribution |
| 00-5446-055-46 | SIZE 5, 46 MM X 34 MM, 7 DEGREE | In distribution |
| 00-5448-004-26 | SIZE 4, 5 MM THICKNESS | In distribution |
| 00-5448-005-38 | SIZE 5, 15 MM THICKNESS | In distribution |
| 00-5447-054-31 | SIZE 4, 31 MM X 31 MM, 0 DEGREE | In distribution |
| 00-5448-006-37 | SIZE 6, 10 MM THICKNESS | In distribution |
| 00-5444-056-31 | SIZE 6, 31 MM x 31 MM, 7 DEGREE | In distribution |
| 00-5445-054-46 | SIZE 4, 46 MM x 34 MM, 0 DEGREE | In distribution |
| 00-5448-005-27 | SIZE 5, 10 MM THICKNESS | In distribution |
| 00-5444-053-31 | SIZE 3, 31 MM x 31 MM, 7 DEGREE | In distribution |
| 00-5446-057-46 | SIZE 7, 46 MM X 34 MM, 7 DEGREE | In distribution |
| 00-5444-055-41 | SIZE 5, 41 MM x 34 MM, 7 DEGREE | In distribution |
| 00-5880-025-10 | SIZE 5, 10 MM THICKNESS | In distribution |
| 00-5446-054-36 | SIZE 4, 36 MM X 31 MM, 7 DEGREE | In distribution |
| 00-5447-055-36 | SIZE 5, 36 MM X 31 MM, 0 DEGREE | In distribution |
| 00-5448-003-10 | SIZE 3, 10 MM THICKNESS | In distribution |
| 00-5445-055-41 | SIZE 5, 41 MM x 34 MM, 0 DEGREE | In distribution |
| 00-5445-055-36 | SIZE 5, 36 MM x 31 MM, 0 DEGREE | In distribution |
| 00-5448-005-36 | SIZE 5, 5 MM THICKNESS | In distribution |
| 00-5490-033-10 | SIZE C, 5 MM AUGMENT | In distribution |
| 00-5448-004-30 | SIZE 4, 30 MM THICKNESS | In distribution |
| 00-5446-054-41 | SIZE 4, 41 MM X 34 MM, 7 DEGREE | In distribution |
| 00-5490-035-01 | SIZE E, 5 MM AUGMENT | In distribution |
| 00-5444-054-36 | SIZE 4, 36 MM x 31 MM, 7 DEGREE | In distribution |
| 00-5878-065-41 | SIZE 41 MM DIA., THICKNESS 10 MM | In distribution |
| 00-5448-004-10 | SIZE 4, 10 MM THICKNESS | In distribution |
| 00-5490-036-10 | SIZE F, 5 MM AUGMENT | In distribution |
| 00-5448-007-37 | SIZE 7, 10 MM THICKNESS | In distribution |
| 00-5880-023-10 | SIZE 3, 10 MM THICKNESS | In distribution |
| 00-5490-033-23 | SIZE C, 15 MM AUGMENT | In distribution |
| 00-5448-004-38 | SIZE 4, 15 MM THICKNESS | In distribution |
| 00-5490-034-10 | SIZE D, 5 MM AUGMENT | In distribution |
| 00-5445-054-41 | SIZE 4, 41 MM x 34 MM, 0 DEGREE | In distribution |
| 00-5444-054-31 | SIZE 4, 31 MM x 31 MM, 7 DEGREE | In distribution |
| 00-5448-005-29 | SIZE 5, 20 MM THICKNESS | In distribution |
| 00-5448-002-28 | SIZE 2, 15 MM THICKNESS | In distribution |
| 00-5448-003-30 | SIZE 3, 30 MM THICKNESS | In distribution |
| 00-5490-035-10 | SIZE E, 5 MM AUGMENT | In distribution |
| 00-5880-022-10 | SIZE 2, 10 MM THICKNESS | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prophecy | Microport Orthopedics Inc. | 4,272 |
| Triathlon | Howmedica Osteonics Corp | 712 |
| Instrument | Howmedica Osteonics Corp | 709 |
| Persona® Vivacit-E® | Zimmer, Inc. | 499 |
| Arthrex® | Arthrex, Inc. | 494 |
| Persona® | Zimmer, Inc. | 441 |
| Legion | Smith & Nephew, Inc. | 397 |
| U2 Total Knee System | United Orthopedic Corp. | 286 |
| Attune | Depuy (Ireland) | 234 |
| DJO Surgical | Encore Medical, L.P. | 191 |
| Vanguard XP Instrumentation | Biomet Orthopedics | 150 |
| Truliant® | Exactech, Inc. | 142 |
Showing 12 of 948. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K120990 | 2012-06-29 |
| K103517 | 2011-02-15 |
| K102896 | 2010-12-13 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Zimmer, Inc. | 510(k) number | 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| Zimmer Trabecular Metal Technology, Inc. | UDI-DI | 2019-02-01 | Class II | Mixed-up of materials/components | Potentially comingled, resulting in the product in the box potentially not matching the product on the label | 24 units | 2020-05-15 |
Recalls
5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-04-15 | Class II | Unknown/Undetermined by firm | Zimmer Biomet is initiating a recall of specific lots of foil pouched, sterile Trabecular Metal implants that were manufactured between April 2011 and October 2012. The foil pouches are part of a dual barrier system to provide sterile integ | 19,884 total | 2017-11-29 |
| 2016-04-15 | Class II | Unknown/Undetermined by firm | Zimmer Biomet is initiating a recall of specific lots of foil pouched, sterile Trabecular Metal implants that were manufactured between April 2011 and October 2012. The foil pouches are part of a dual barrier system to provide sterile integ | 19,884 total | 2017-11-29 |
| 2016-04-15 | Class II | Unknown/Undetermined by firm | Zimmer Biomet is initiating a recall of specific lots of foil pouched, sterile Trabecular Metal implants that were manufactured between April 2011 and October 2012. The foil pouches are part of a dual barrier system to provide sterile integ | 19,884 total | 2017-11-29 |
| 2016-04-15 | Class II | Unknown/Undetermined by firm | Zimmer Biomet is initiating a recall of specific lots of foil pouched, sterile Trabecular Metal implants that were manufactured between April 2011 and October 2012. The foil pouches are part of a dual barrier system to provide sterile integ | 19,884 total | 2017-11-29 |
| 2015-02-04 | Class II | Error in labeling | One unit of the 20 mm augments was mislabeled as 5 mm and it was subsequently distributed. | 1 unit | 2015-07-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.