Regenerex®
14 catalogue numbers from 184602, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer. 12 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | MBH |
| Device type | Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3565 |
| 510(k) | K072336 |
| Record published | 2018-07-23 |
| Record revised | 2025-05-30 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 184602 | 25 mm Small | In distribution |
| 184605 | 40 mm X-Small | In distribution |
| 141276 | 83 MM | In distribution |
| 141272 | 67 MM | In distribution |
| 141270 | 59 MM | In distribution |
| 141277 | 87 MM | In distribution |
| 184603 | 25 MM MEDIUM | In distribution |
| 184607 | 40 mm Medium | In distribution |
| 141274 | 75 MM | In distribution |
| 141275 | 79 MM | In distribution |
| 184607 | 40 MM MEDIUM | In distribution |
| 141271 | 63 MM | In distribution |
| 184605 | 40 MM X-SMALL | In distribution |
| 184608 | 40 MM LARGE | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prophecy | Microport Orthopedics Inc. | 4,272 |
| Triathlon | Howmedica Osteonics Corp | 712 |
| Instrument | Howmedica Osteonics Corp | 709 |
| Persona® Vivacit-E® | Zimmer, Inc. | 499 |
| Arthrex® | Arthrex, Inc. | 494 |
| Persona® | Zimmer, Inc. | 441 |
| Legion | Smith & Nephew, Inc. | 397 |
| U2 Total Knee System | United Orthopedic Corp. | 286 |
| Attune | Depuy (Ireland) | 234 |
| DJO Surgical | Encore Medical, L.P. | 191 |
| Vanguard XP Instrumentation | Biomet Orthopedics | 150 |
| Truliant® | Exactech, Inc. | 142 |
Showing 12 of 948. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2020-09-04 | Class II | Process change control | Product not properly being aligned with the adequate gamma sterilization group and result in the product not being properly sterilized | US: 62 units; OUS: 176 units | 2021-08-31 |
| Biomet, Inc. | 510(k) number | 2018-12-21 | Class II | Under Investigation by firm | Vanguard Knee System Series-A Standard Patella a potential commingle that could result in the size of the implant not matching the size on the label. | 90 units | 2020-05-13 |
| Biomet, Inc. | 510(k) number | 2018-05-24 | Class II | Under Investigation by firm | Two lots of tibial bearings were commingled. There is a possibility that a 14mm tibial bearing is packaged in a box labeled as 12 mm tibial bearing and vice versa. This may lead to extension of surgery to find another implant. | 48 | 2020-04-07 |
| Biomet, Inc. | 510(k) number | 2018-05-18 | Class II | Under Investigation by firm | One lot of 75mm tibial tray is potentially etched and labeled as a 79 mm tibial tray. This may lead to delay in surgery, or immediate revision surgery to remove an incorrectly sized tibial component after it has been cemented. | 16 | 2020-03-31 |
| Biomet, Inc. | 510(k) number | 2018-05-11 | Class II | Under Investigation by firm | The label master file was errantly set up as a 63/37mm instead of a 63/67mm. There is no 63/37 size offered, and the product is laser marked with the correct size. | 169 | 2019-11-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.