Scorpio

Resurfacing Patellar Component

Registry build 21.09.26
12manufacturers in China registered for this device type
77catalogue numbers in this listing
9510(k) clearances naming this product code
26recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MBH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Scorpio
Listed by Howmedica Osteonics Corp, United States
FDA product code MBH
Device type Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3565
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
510(k) K033971
Record published 2015-09-24
Record revised 2021-02-05 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Scorpio
Catalogue number Size Status
70-5211R Type: CR In distribution
72-25-0315 Thickness: 15.0 Millimeter In distribution
72-26-0310 Type: CR In distribution
71-5207R Side: RIGHT In distribution
70-5209L Type: CR In distribution
70-5206L Type: CR In distribution
72-25-0715 Thickness: 15.0 Millimeter In distribution
70-5206R Size: 6 In distribution
73-20-5032 Thickness: 10.0 Millimeter In distribution
72-25-0915 Thickness: 15.0 Millimeter In distribution
72-25-0908 Size: 9 In distribution
71-5209R Side: RIGHT In distribution
71-5206R Type: PS In distribution
72-26-1121 Type: CR In distribution
70-5205R Side: RIGHT In distribution
73-20-4030 Diameter: 30.0 Millimeter In distribution
72-26-0715 Type: CR In distribution
71-5203R Side: RIGHT In distribution
72-26-0315 Type: CR In distribution
72-25-0321 Size: 3 In distribution
72-26-0521 Size: 5 In distribution
71-5211R Side: RIGHT In distribution
72-26-0912 Type: CR In distribution
73-20-5030 Diameter: 30.0 Millimeter In distribution
72-25-0310 Size: 3 In distribution
70-5211L Type: CR In distribution
73-20-2110 Thickness: 10.0 Millimeter In distribution
70-5204R Side: RIGHT In distribution
71-5207L Size: 7 In distribution
72-26-0312 Type: CR In distribution
72-26-0318 Type: CR In distribution
73-20-4032 Diameter: 32.0 Millimeter In distribution
72-25-1110 Thickness: 10.0 Millimeter In distribution
72-26-0308 Type: CR In distribution
72-26-0721 Size: 7 In distribution
70-5205L Size: 5 In distribution
72-25-0515 Size: 5 In distribution
70-5213L Side: LEFT In distribution
72-25-0912 Type: PS In distribution
72-26-1110 Thickness: 10.0 Millimeter In distribution
71-5209L Side: LEFT In distribution
70-5209R Size: 9 In distribution
72-26-0508 Type: CR In distribution
72-26-0718 Type: CR In distribution
72-26-0518 Type: CR In distribution
71-5213R Side: RIGHT In distribution
72-25-0712 Thickness: 12.0 Millimeter In distribution
72-26-1118 Type: CR In distribution
73-20-2910 Thickness: 10.0 Millimeter In distribution
72-26-0724 Thickness: 24.0 Millimeter In distribution
72-26-0321 Size: 3 In distribution
70-5207L Size: 7 In distribution
73-20-0710 Size: 7 In distribution
73-20-0110 Thickness: 10.0 Millimeter In distribution
70-5203R Type: CR In distribution
72-25-0308 Type: PS In distribution
71-5204L Type: PS In distribution
71-5206L Type: PS In distribution
70-5204L Size: 4 In distribution
71-5205L Size: 5 In distribution
70-5203L Side: LEFT In distribution
72-26-0915 Size: 9 In distribution
72-26-1108 Thickness: 8.0 Millimeter In distribution
72-25-1124 Size: 11 In distribution
72-25-0724 Type: PS In distribution
70-5213R Type: CR In distribution
72-25-0318 Thickness: 18.0 Millimeter In distribution
71-5204R Type: PS In distribution
72-25-0512 Type: PS In distribution
72-26-0515 Type: CR In distribution
71-5211L Side: LEFT In distribution
72-26-0918 Size: 9 In distribution
71-5213L Size: 13 In distribution
72-26-0924 Type: CR In distribution
71-5205R Type: PS In distribution
71-5203L Size: 3 In distribution
70-5207R Side: RIGHT In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy Microport Orthopedics Inc. 4,272
Triathlon Howmedica Osteonics Corp 712
Instrument Howmedica Osteonics Corp 709
Persona® Vivacit-E® Zimmer, Inc. 499
Arthrex® Arthrex, Inc. 494
Persona® Zimmer, Inc. 441
Legion Smith & Nephew, Inc. 397
U2 Total Knee System United Orthopedic Corp. 286
Attune Depuy (Ireland) 234
DJO Surgical Encore Medical, L.P. 191
Vanguard XP Instrumentation Biomet Orthopedics 150
Truliant® Exactech, Inc. 142

Showing 12 of 948. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K200782 2020-05-13
K070883 2007-05-11
K061521 2006-08-11
K051380 2005-08-30
K043374 2005-02-16
K033971 2004-05-28
K033972 2004-04-12
K032163 2003-09-12
K032418 2003-09-11

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Scorpio
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Howmedica Osteonics Corp 510(k) number 2006-02-17 Not classified Process design Stryker Orthopaedics became aware of a potential anomaly related to the packaging process of referenced lots of X# polyethylene used on Scorpio, Triathlon and Trident inserts. 594 units total – all products. 2010-03-03

Recalls

1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-30 Not classified Process change control Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to 12,156 US
2026-05-19 Class II Under Investigation by firm Stryker has identified that Triathlon Universal Baseplate Size 3 (lot UZD9IB), is contained in packaging labeled as Triathlon Universal Baseplate Size 4 (lot TYX7OB), and Triathlon Universal Baseplate Size 4 (lot TYX7OB), is contained in pa 7 units
2026-05-19 Class II Under Investigation by firm Stryker has identified that Triathlon Universal Baseplate Size 3 (lot UZD9IB), is contained in packaging labeled as Triathlon Universal Baseplate Size 4 (lot TYX7OB), and Triathlon Universal Baseplate Size 4 (lot TYX7OB), is contained in pa 7 units
2024-02-06 Class II Packaging Potential packaging breaches of inner blister and outer sterile blister. 39 units (US); 10 units (OUS)
2024-02-06 Class II Packaging Potential packaging breaches of inner blister and outer sterile blister. 143 units (US)
2024-02-06 Class II Packaging Potential packaging breaches of inner blister and outer sterile blister. 37 units (US); 10 units (OUS)
2024-02-06 Class II Packaging Potential packaging breaches of inner blister and outer sterile blister. 24 units (US)
2024-02-06 Class II Packaging Potential packaging breaches of inner blister and outer sterile blister. 24 units (US)
2024-02-06 Class II Packaging Potential packaging breaches of inner blister and outer sterile blister. 24 units (US); 1 unit (OUS)
2024-02-06 Class II Packaging Potential packaging breaches of inner blister and outer sterile blister. 132 units (US); 26 units (OUS)
2024-02-06 Class II Packaging Potential packaging breaches of inner blister and outer sterile blister. 18 units (US); 5 units (OUS)
2023-04-13 Class II Under Investigation by firm Mislabeled:Labeled Catalog Number: 5531-G-312-E, TRIATHLON X3 TIBIAL BEARING INSERT CS #3 12MM, may contain Catalog Number: 5532-G-413-E, TRIATHLON X3 TIBIAL BEARING INSERT PS #4 13MM, and vice versa 24 units in total
2023-04-13 Class II Under Investigation by firm Mislabeled:Labeled Catalog Number: 5531-G-312-E, TRIATHLON X3 TIBIAL BEARING INSERT CS #3 12MM, may contain Catalog Number: 5532-G-413-E, TRIATHLON X3 TIBIAL BEARING INSERT PS #4 13MM, and vice versa 24 units in total
2021-02-10 Class II Under Investigation by firm Stryker has discovered that the internal profile of the Triathlon Tritanium Tibial Component (Baseplate), size 4, is potentially oversized. Due to a manufacturing issue in Lot Number CTD44301, there may be a witness mark (taper) at the bott 11 devices 2023-05-30
2019-08-19 Class II Device Design Due to device overhang issue that protrudes beyond the medial periphery of the mating femoral component 171 units 2020-05-06
2019-08-19 Class II Device Design Due to device overhang issue that protrudes beyond the medial periphery of the mating femoral component 153 units 2020-05-06
2019-08-19 Class II Device Design Due to device overhang issue that protrudes beyond the medial periphery of the mating femoral component 167 units 2020-05-06
2019-08-19 Class II Device Design Due to device overhang issue that protrudes beyond the medial periphery of the mating femoral component 159 units 2020-05-06
2018-01-30 Class II Under Investigation by firm Customers may receive the incorrect size implant from what is labeled on the box. 77 total products 2020-05-07
2018-01-12 Class II Error in labeling Firm became aware that the specific product/lot combinations referenced above may contain the incorrect size implant from what is labeled on the box. 6 units of catalog 5521-B-400 2020-05-07
2016-08-01 Class II Nonconforming Material/Component Upon failure of the press-fit, the clamping sub components and pins could disassociate from the Scorpio Patella Assembly Instrument. 2,039 units 2017-06-08
2016-06-23 Class II Process control It was reported that the secondary locking mechanism, and its corresponding components, disassociated from the Specialty Triathlon Tibial Alignment Handle with Secondary Lock Assembly during surgery. Upon further investigation, it was disco 47 units 2018-08-01
2015-05-29 Class II Labeling mix-ups Stryker has received a report which identified that a Triathlon Tibial Bearing Insert CS X3 Size #2 9mm (5531-G-209) was reported to be in a pack that was labelled as a CR insert (5530-G-209). 10 units 2016-09-26
2015-02-12 Class II Device Design Potential for weld disassociation of the cross pin, which could lead to loose or disassociated trigger mechanism on the Distal Capture Assembly. 2030 units 2016-07-05
2012-11-08 Class I Device Design With regards to ShapeMatch Cutting Guides using MRI Imaging, Stryker Orthopaedics
has become aware that there are potential issues associated with internal processes
for planning cases and producing ShapeMatch Cutting Guides.
7868 units 2021-01-11
2006-09-21 Not classified Process change control Stryker Orthopaedics became aware that one lot of the Triathlon Primary Beaded PA Baseplate Size 5 may not have the Peri-Apatite coating. 10 2009-01-09

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer