CinchLock
FG, Cinchlock SS Anchor With Inserter
7manufacturers in China registered for this device type
1catalogue number
10510(k) clearances naming this product code
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Renolit Hansen Packaging Tech. (BJ) Ltd. | Beijing | Beijing | Contract manufacturer | 1 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Suzhou Endophix Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 17 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | MBI |
| Device type | Fastener, Fixation, Nondegradable, Soft Tissue |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K131769 |
| Record published | 2015-09-04 |
| Record revised | 2019-03-21 (version 5) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| CAT02462 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arthrex® | Arthrex, Inc. | 362 |
| HNM Sports Medicine | HNM Stainless, LLC. | 150 |
| Suture Anchors – HTA Headless Titanium Anchor and Zip Anchors | GM DOS Reis Industria E Comercio Ltda | 78 |
| Juggerknot® | Biomet Orthopedics | 77 |
| Fastener, Fixation, Nondegradable, Soft Tissue | Parcus Medical, LLC | 74 |
| endophix | Suzhou Endophix Co., Ltd. | 71 |
| Titan | Medline Industries, Inc. | 68 |
| TopLock | Fusion Orthopedics, LLC | 67 |
| HNM Medical | HNM Stainless, LLC. | 59 |
| Orthobutton CL | Riverpoint Medical LLC | 55 |
| Apollo | Medline Industries, Inc. | 53 |
| JuggerKnot Soft Anchor | Riverpoint Medical LLC | 46 |
Showing 12 of 618. All products under Fastener, Fixation, Nondegradable, Soft Tissue
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K202355 | 2020-11-13 |
| K181083 | 2018-07-23 |
| K173074 | 2018-04-04 |
| K172921 | 2017-11-20 |
| K171465 | 2017-08-24 |
| K170098 | 2017-03-31 |
| K151201 | 2015-06-29 |
| K133671 | 2014-02-28 |
| K120509 | 2012-07-26 |
| K120824 | 2012-07-18 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Stryker Endoscopy | 510(k) number | 2023-08-23 | Class II | Unknown/Undetermined by firm | Expired Product distributed | 96 units | |
| Stryker Endoscopy | 510(k) number | 2016-04-12 | Class II | Device Design | Stryker Endoscopy is recalling the CinchLock SS Knotless Anchor with Inserter and the CinchLock Flex Anchor with Inserter after 13 reports of s of an internal wire breaking upon deployment of the anchor. | 3100 total device, both model numbers. | 2016-12-12 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.