Healix Transtend Orthocord
HEALIX TI 3-Suture Anchor w/ORTHOCORD Titanium Anchor (1) Violet (1) Blue Strand, (1) Blue Striped, Size 2 (5 metric) ORTHOCORD braided composite suture, 36 Inches (91cm) 4.5mm
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Renolit Hansen Packaging Tech. (BJ) Ltd. | Beijing | Beijing | Contract manufacturer | 1 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Suzhou Endophix Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 17 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
Record
| Listed by | Medos International Sàrl, Switzerland |
|---|---|
| FDA product code | MBI |
| Device type | Fastener, Fixation, Nondegradable, Soft Tissue |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| 510(k) | K071481 |
| Record published | 2015-09-01 |
| Record revised | 2025-03-25 (version 7) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature up to 77 °F; Handling environment temperature up to 25 °C; Handling environment temperature up to 77 °F; Storage environment temperature up to 25 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 222271 | In distribution | |
| 222265 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arthrex® | Arthrex, Inc. | 362 |
| HNM Sports Medicine | HNM Stainless, LLC. | 150 |
| Suture Anchors – HTA Headless Titanium Anchor and Zip Anchors | GM DOS Reis Industria E Comercio Ltda | 78 |
| Juggerknot® | Biomet Orthopedics | 77 |
| Fastener, Fixation, Nondegradable, Soft Tissue | Parcus Medical, LLC | 74 |
| endophix | Suzhou Endophix Co., Ltd. | 71 |
| Titan | Medline Industries, Inc. | 68 |
| TopLock | Fusion Orthopedics, LLC | 67 |
| HNM Medical | HNM Stainless, LLC. | 59 |
| Orthobutton CL | Riverpoint Medical LLC | 55 |
| Apollo | Medline Industries, Inc. | 53 |
| JuggerKnot Soft Anchor | Riverpoint Medical LLC | 46 |
Showing 12 of 618. All products under Fastener, Fixation, Nondegradable, Soft Tissue
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 805 units |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 540 units |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 2372 units |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 3328 units |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 1125 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.