Core Lumbar Fixation System
TI STANDARD PEDICLE BOLT - 7.5mm X 35mm
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (2), Shandong (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Changzhou Yonghua Medical Instruments Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 8 |
| Jiangsu Ideal Medical Science & Technology Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 7 |
Showing 12 of 13. All 13 manufacturers in China registered for Orthosis, Spondylolisthesis Spinal Fixation
Record
| Listed by | Alphatec Spine, Inc., United States |
|---|---|
| FDA product code | MNH |
| Device type | Orthosis, Spondylolisthesis Spinal Fixation |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3070 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K090228 |
| Record published | 2020-07-23 |
| Record revised | 2025-07-14 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Sizes | Outer diameter 6.5 to 8.5 mm; length 35 to 80 mm |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 81275-335 | Outer Diameter 7.5 mm | In distribution |
| 81009-25 | In distribution | |
| 81285-350 | Length 50 mm | In distribution |
| 81100-39 | In distribution | |
| 81265-845 | Outer Diameter 6.5 mm | In distribution |
| 81100-30 | In distribution | |
| 81009 | In distribution | |
| 81003-062 | In distribution | |
| 81003-090 | In distribution | |
| 81285-380 | Outer Diameter 8.5 mm | In distribution |
| 81285-345 | Length 45 mm | In distribution |
| 81265-340 | Outer Diameter 6.5 mm | In distribution |
| 81003-076 | In distribution | |
| 81004-114 | In distribution | |
| 81006 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 3,144 |
| Anax™ 5.5 Spinal System | CG MedTech Co., Ltd. | 2,177 |
| ReLine | Nuvasive, Inc. | 2,010 |
| Creo | Globus Medical, Inc. | 1,619 |
| Perfix™ Spinal System | CG MedTech Co., Ltd. | 1,476 |
| Apex Spine System | Spinecraft LLC | 1,193 |
| Olympic | Astura Medical | 1,173 |
| Arsenal | Alphatec Spine, Inc. | 1,001 |
| Revere | Globus Medical, Inc. | 997 |
| Astra Spine System | Spinecraft LLC | 798 |
| Apex-DL Spine System | Spinecraft LLC | 735 |
| Zenius Spinal System | Medyssey Co., Ltd. | 712 |
Showing 12 of 811. All products under Orthosis, Spondylolisthesis Spinal Fixation
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K090228 | 2009-04-29 |
| K071890 | 2007-11-09 |
| K061321 | 2006-07-07 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-09-25 | Class II | Nonconforming Material/Component | The firm initiated the recall because the stainless steel guide-wire of the Illico MIS Fixation System did not completely fit/pass through the tip of certain Illico Ti Cannulated Polyaxial Screws, therefore rendering such screws nonfunction | 209 screws | 2013-03-29 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.