Streamline TL Spinal Fixation System
STREAMLINE TL, Ø6.5MM DL CANNULATED PEDICLE REDUCTION SCREW ASSEMBLY, 100mm
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (2), Shandong (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Changzhou Yonghua Medical Instruments Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 8 |
| Jiangsu Ideal Medical Science & Technology Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 7 |
Showing 12 of 13. All 13 manufacturers in China registered for Orthosis, Spondylolisthesis Spinal Fixation
Record
| Listed by | Xtant Medical Holdings, Inc., United States |
|---|---|
| FDA product code | MNH |
| Device type | Orthosis, Spondylolisthesis Spinal Fixation |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3070 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K140696 |
| Record published | 2026-06-02 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 01-RS-C-85-80 | In distribution | |
| 01-RS-C-65-100 | In distribution | |
| 10-55-RHC-400 | In distribution | |
| 01-RS-C-85-30 | In distribution | |
| 01-PA-105-100 | In distribution | |
| 01-FX-65-95 | In distribution | |
| 01-PA-C-85-80 | In distribution | |
| 10-55-PR-55 | In distribution | |
| 10-55-RH-400 | In distribution | |
| 01-FX-75-85 | In distribution | |
| 01-RS-C-65-70 | In distribution | |
| 10-55-PR-140 | In distribution | |
| 10-55-PR-135 | In distribution | |
| 10-55-PR-90 | In distribution | |
| 01-PA-105-70 | In distribution | |
| 01-PA-C-85-95 | In distribution | |
| 01-PA-85-25 | In distribution | |
| 10-55-PR-50 | In distribution | |
| 01-RS-C-85-65 | In distribution | |
| 01-RS-75-85 | In distribution | |
| 01-RS-C-65-80 | In distribution | |
| 01-FX-65-100 | In distribution | |
| 01-RS-75-90 | In distribution | |
| 01-PA-C-85-85 | In distribution | |
| 10-55-RHC-200 | In distribution | |
| 01-RS-65-90 | In distribution | |
| 01-PA-C-75-90 | In distribution | |
| 01-RS-C-65-75 | In distribution | |
| 01-RS-75-80 | In distribution | |
| 01-FX-75-70 | In distribution | |
| 10-55-RR-70 | In distribution | |
| 10-55-PR-95 | In distribution | |
| 01-RS-C-65-65 | In distribution | |
| 10-55-PR-35 | In distribution | |
| 10-55-PR-45 | In distribution | |
| 10-55-PR-40 | In distribution | |
| 01-PA-115-90 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 3,144 |
| Anax™ 5.5 Spinal System | CG MedTech Co., Ltd. | 2,177 |
| ReLine | Nuvasive, Inc. | 2,010 |
| Creo | Globus Medical, Inc. | 1,619 |
| Perfix™ Spinal System | CG MedTech Co., Ltd. | 1,476 |
| Apex Spine System | Spinecraft LLC | 1,193 |
| Olympic | Astura Medical | 1,173 |
| Arsenal | Alphatec Spine, Inc. | 1,001 |
| Revere | Globus Medical, Inc. | 997 |
| Astra Spine System | Spinecraft LLC | 798 |
| Apex-DL Spine System | Spinecraft LLC | 735 |
| Zenius Spinal System | Medyssey Co., Ltd. | 712 |
Showing 12 of 811. All products under Orthosis, Spondylolisthesis Spinal Fixation
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-04-12 | Class II | Labeling mix-ups | The material type on the label may incorrectly state Ti6Al-4V ELI. The rods are composed of Cobalt Chromium. | 97 units | 2017-08-16 |
| 2015-04-07 | Class II | Other | The Continuous Radius Rod should measure 50mm in length but actually measures 45mm in length. | 75 units | 2015-10-01 |
| 2015-03-11 | Class II | Nonconforming Material/Component | One lot of instruments have etched on the Yoke of the Pedicle Screw a laser marking size of 7.5 x 55mm instead of 5.5 x 55mm as described on the product label. | 14 units | 2015-10-21 |
| 2009-03-24 | Not classified | Process control | A defect cause was discovered following a customer complaint pertaining to a post operative dissociation of the Capless Li Screw construct. The screw assembly is made up of three parts; a cup which locks onto a 5.5mm rod, a yoke that cradl | 9,613 units | 2012-04-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.