X90 Pedicle Screw System

Sterilization Case, Capless (or X90) System, Instrument

Registry build 21.09.26
13manufacturers in China registered for this device type
17catalogue numbers in this listing
4recalls on this code

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (2), Shandong (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MNH
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Changzhou Yonghua Medical Instruments Co., Ltd. Changzhou Jiangsu Manufacturer 8
Jiangsu Ideal Medical Science & Technology Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7

Showing 12 of 13. All 13 manufacturers in China registered for Orthosis, Spondylolisthesis Spinal Fixation

Record

Regulatory record for X90 Pedicle Screw System
Listed by Xtant Medical Holdings, Inc., United States
FDA product code MNH
Device type Orthosis, Spondylolisthesis Spinal Fixation
Device class Class 2
Regulation 21 CFR 888.3070
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2015-09-28
Record revised 2025-07-14 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for X90 Pedicle Screw System
Catalogue number Size Status
N60000490 In distribution
N60000771 In distribution
N60001576 In distribution
N60001575 In distribution
N60002105 In distribution
N60000274 In distribution
N60001553 In distribution
N60001620 In distribution
N60001001 In distribution
N60001554 In distribution
N60000513 In distribution
N60002200 In distribution
CN60-0026 In distribution
N60000788 In distribution
N60000494 In distribution
N60000500 In distribution
N60000475 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 3,144
Anax™ 5.5 Spinal System CG MedTech Co., Ltd. 2,177
ReLine Nuvasive, Inc. 2,010
Creo Globus Medical, Inc. 1,619
Perfix™ Spinal System CG MedTech Co., Ltd. 1,476
Apex Spine System Spinecraft LLC 1,193
Olympic Astura Medical 1,173
Arsenal Alphatec Spine, Inc. 1,001
Revere Globus Medical, Inc. 997
Astra Spine System Spinecraft LLC 798
Apex-DL Spine System Spinecraft LLC 735
Zenius Spinal System Medyssey Co., Ltd. 712

Showing 12 of 811. All products under Orthosis, Spondylolisthesis Spinal Fixation

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-04-12 Class II Labeling mix-ups The material type on the label may incorrectly state Ti6Al-4V ELI. The rods are composed of Cobalt Chromium. 97 units 2017-08-16
2015-04-07 Class II Other The Continuous Radius Rod should measure 50mm in length but actually measures 45mm in length. 75 units 2015-10-01
2015-03-11 Class II Nonconforming Material/Component One lot of instruments have etched on the Yoke of the Pedicle Screw a laser marking size of 7.5 x 55mm instead of 5.5 x 55mm as described on the product label. 14 units 2015-10-21
2009-03-24 Not classified Process control A defect cause was discovered following a customer complaint pertaining to a post operative dissociation of the Capless Li Screw construct. The screw assembly is made up of three parts; a cup which locks onto a 5.5mm rod, a yoke that cradl 9,613 units 2012-04-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer