Preference Pedicle Screw System

7.2mm Polyaxial Screw Reduction 40mm Green

Registry build 21.09.26
13manufacturers in China registered for this device type
6catalogue numbers in this listing
1recall

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (2), Shandong (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MNI
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Changzhou Yonghua Medical Instruments Co., Ltd. Changzhou Jiangsu Manufacturer 8
Jiangsu Ideal Medical Science & Technology Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7

Showing 12 of 13. All 13 manufacturers in China registered for Orthosis, Spinal Pedicle Fixation

Record

Regulatory record for Preference Pedicle Screw System
Listed by CTL Medical Corporation, United States
FDA product code MNI
Device type Orthosis, Spinal Pedicle Fixation
Device class Class 2
Regulation 21 CFR 888.3070
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K081296
Record published 2024-10-03
Record revised 2026-05-14 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Preference Pedicle Screw System
Catalogue number Size Status
10-2961-536 In distribution
10-2961-530 In distribution
28-7201-040 In distribution
10-2961-534 In distribution
28-7200-050 In distribution
10-2961-528 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 2,342
Creo Globus Medical, Inc. 1,784
ReLine Nuvasive, Inc. 1,718
AnyPlus Spinal Fixation System GS Medical Co., Ltd. 1,525
Apex Spine System Spinecraft LLC 1,114
Revere Globus Medical, Inc. 1,051
LnK Spinal Fixation System L&K Biomed Co., Ltd. 974
LnK Basic Spinal Fixation System L&K Biomed Co., Ltd. 935
Arsenal Alphatec Spine, Inc. 932
Zavation Zavation 864
Polaris™ 5.5 Spinal System Biomet Spine 809
Apex-DL Spine System Spinecraft LLC 792

Showing 12 of 950. All products under Orthosis, Spinal Pedicle Fixation

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-07-05 Class II Nonconforming Material/Component the anti-toggle ring of the hex driver may separate from the driver shaft. If this occurs during surgery, the anti-toggle ring can be pressed into the pedicle screw head and cause separation of the screw from the housing upon tightening. i 133 total devices 2021-04-28

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer