Renoir Posterior Cervical Fixation System

RENOIR™ Implant Module, D3.5 Rod, 3.5 and 4.0 Polyaxial Screws

Registry build 21.09.26
13manufacturers in China registered for this device type
85catalogue numbers in this listing
1recall

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (2), Shandong (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MNI
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Changzhou Yonghua Medical Instruments Co., Ltd. Changzhou Jiangsu Manufacturer 8
Jiangsu Ideal Medical Science & Technology Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7

Showing 12 of 13. All 13 manufacturers in China registered for Orthosis, Spinal Pedicle Fixation

Record

Regulatory record for Renoir Posterior Cervical Fixation System
Listed by CTL Medical Corporation, United States
FDA product code MNI
Device type Orthosis, Spinal Pedicle Fixation
Device class Class 2
Regulation 21 CFR 888.3070
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K121136
Record published 2024-01-04
Record revised 2025-12-03 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Renoir Posterior Cervical Fixation System
Catalogue number Size Status
012.7010 In distribution
012.0200 In distribution
012.1520 In distribution
012.1351 In distribution
012.1200 In distribution
012.0520 In distribution
012.1418 In distribution
012.8136 In distribution
012.0510 In distribution
012.0320 In distribution
012.1416 In distribution
012.0220 In distribution
012.1836 In distribution
012.0420 In distribution
012.1360 In distribution
012.1404 In distribution
012.1514 In distribution
012.1512 In distribution
012.1826 In distribution
012.1365 In distribution
012.0500 In distribution
012.8110 In distribution
012.1522 In distribution
012.8135 In distribution
012.1528 In distribution
012.1040 In distribution
012.1309 In distribution
012.1428 In distribution
012.1426 In distribution
012.1524 In distribution
012.1363 In distribution
012.1816 In distribution
012.1080 In distribution
012.1451 In distribution
012.1357 In distribution
012.1424 In distribution
012.1422 In distribution
012.0410 In distribution
012.1530 In distribution
012.1362 In distribution
012.1526 In distribution
012.8710 In distribution
012.1405 In distribution
012.1432 In distribution
012.1050 In distribution
012.1070 In distribution
012.1536 In distribution
012.1534 In distribution
012.1408 In distribution
012.1251 In distribution
012.1436 In distribution
012.7068 In distribution
012.1434 In distribution
012.7101 In distribution
012.1420 In distribution
012.0300 In distribution
012.0310 In distribution
012.1364 In distribution
012.7070 In distribution
012.7067 In distribution
012.7009 In distribution
012.1356 In distribution
012.1361 In distribution
012.1240 In distribution
012.1030 In distribution
012.1355 In distribution
012.1518 In distribution
012.1120 In distribution
012.1410 In distribution
012.1354 In distribution
012.1516 In distribution
012.1358 In distribution
012.1412 In distribution
012.1510 In distribution
012.1430 In distribution
012.0210 In distribution
012.1090 In distribution
012.1060 In distribution
012.1359 In distribution
012.7074 In distribution
012.0400 In distribution
012.7071 In distribution
012.1414 In distribution
012.1532 In distribution
012.1100 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 2,342
Creo Globus Medical, Inc. 1,784
ReLine Nuvasive, Inc. 1,718
AnyPlus Spinal Fixation System GS Medical Co., Ltd. 1,525
Apex Spine System Spinecraft LLC 1,114
Revere Globus Medical, Inc. 1,051
LnK Spinal Fixation System L&K Biomed Co., Ltd. 974
LnK Basic Spinal Fixation System L&K Biomed Co., Ltd. 935
Arsenal Alphatec Spine, Inc. 932
Zavation Zavation 864
Polaris™ 5.5 Spinal System Biomet Spine 809
Apex-DL Spine System Spinecraft LLC 792

Showing 12 of 950. All products under Orthosis, Spinal Pedicle Fixation

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-07-05 Class II Nonconforming Material/Component the anti-toggle ring of the hex driver may separate from the driver shaft. If this occurs during surgery, the anti-toggle ring can be pressed into the pedicle screw head and cause separation of the screw from the housing upon tightening. i 133 total devices 2021-04-28

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer