BoneSync Fast-Setting Drillable Calcium Phosphate Cement
Fast-Setting Drillable Calcium Phosphate Cement
2manufacturers in China registered for this device type
3catalogue numbers in this listing
1510(k) clearance
Who Else Makes It
Concentrated in Shanghai (1), Beijing (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Allgens Medical Technology Co., Ltd. | Beijing | Beijing | Complaint-file establishment | 1 |
Record
| Listed by | DSM Biomedical, Inc., United States |
|---|---|
| FDA product code | MQV |
| Device type | Filler, Bone Void, Calcium Compound |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3045 |
| Establishment | Contract manufacturer, Manufacturer |
| Record published | 2019-01-02 |
| Record revised | 2023-07-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Sizes | Total volume 3 to 5 ml |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 21003-03 | Total Volume 3 ml | In distribution |
| 21003-10 | Total Volume 5 ml | In distribution |
| 21003-04 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Synthacer | medArtis Medizinprodukte und Forschung Aktiengesellschaft | 360 |
| Syntricer | medArtis Medizinprodukte und Forschung Aktiengesellschaft | 357 |
| Biosorb | S.B.M | 65 |
| MagnetOs | Kuros Biosciences B.V | 61 |
| BioSet® | Rti Surgical, Inc. | 47 |
| Bicera® Resorbable Bone Substitute | Wiltrom Corporation Limited | 41 |
| GRAFTON®and Grafton PLUS®Demineralized Bone Matrix (DBM) | Medtronic Sofamor Danek, Inc. | 40 |
| Bicera® Resorbable Bone Substitute | Wiltrom Co., Ltd. (Chutung) | 39 |
| ChronOS | Synthes Gmbh | 39 |
| Synthacer/Syntricer | medArtis Medizinprodukte und Forschung Aktiengesellschaft | 36 |
| Inion BioRestore™ | Inion OY | 35 |
| Resorba Synthetic Bone | Biomatlante | 35 |
Showing 12 of 750. All products under Filler, Bone Void, Calcium Compound
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K230054 | 2023-03-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.