Norian
Norian Drillable Fast SET Putty 10CC-STERILE
2manufacturers in China registered for this device type
6catalogue numbers in this listing
1510(k) clearance
Who Else Makes It
Concentrated in Shanghai (1), Beijing (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Allgens Medical Technology Co., Ltd. | Beijing | Beijing | Complaint-file establishment | 1 |
Record
| Listed by | Synthes Gmbh, Switzerland |
|---|---|
| FDA product code | MQV |
| Device type | Filler, Bone Void, Calcium Compound |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3045 |
| Establishment | Specification developer, Manufacturer, Exporter |
| 510(k) | K073303 |
| Record published | 2015-09-14 |
| Record revised | 2026-05-21 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 5 to 25 °C; Handling environment temperature up to 43 °C; Special storage condition:. |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 07.704.010S | In distribution | |
| 07.704.103S | In distribution | |
| 07.704.110S | In distribution | |
| 07.704.005S | In distribution | |
| 07.704.003S | In distribution | |
| 07.704.105S | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Synthacer | medArtis Medizinprodukte und Forschung Aktiengesellschaft | 360 |
| Syntricer | medArtis Medizinprodukte und Forschung Aktiengesellschaft | 357 |
| Biosorb | S.B.M | 65 |
| MagnetOs | Kuros Biosciences B.V | 61 |
| BioSet® | Rti Surgical, Inc. | 47 |
| Bicera® Resorbable Bone Substitute | Wiltrom Corporation Limited | 41 |
| GRAFTON®and Grafton PLUS®Demineralized Bone Matrix (DBM) | Medtronic Sofamor Danek, Inc. | 40 |
| Bicera® Resorbable Bone Substitute | Wiltrom Co., Ltd. (Chutung) | 39 |
| ChronOS | Synthes Gmbh | 39 |
| Synthacer/Syntricer | medArtis Medizinprodukte und Forschung Aktiengesellschaft | 36 |
| Inion BioRestore™ | Inion OY | 35 |
| Resorba Synthetic Bone | Biomatlante | 35 |
Showing 12 of 750. All products under Filler, Bone Void, Calcium Compound
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K013072 | 2002-11-26 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Synthes (USA) Products LLC | 510(k) number | 2017-08-10 | Class II | Process control | The contract supplier notified DePuy Synthes on June 16, 2017 that the kit expiration dates do not align with the earliest expiration date of the component lots within the kit. Some kit expiration dates were later than the earliest expirati | 5 units | 2018-09-10 |
| Synthes (USA) Products LLC | 510(k) number | 2016-05-11 | Class II | Under Investigation by firm | DePuy Synthes is initiating a voluntary medical device recall of unexpired and unopened part and lot numbers for the Norian Drillable Injects-Sterile due to the rotary pouch within the referenced lots and associated part numbers may potenti | 1246 units | 2017-03-10 |
| Synthes (USA) Products LLC | 510(k) number | 2016-05-11 | Class II | Under Investigation by firm | DePuy Synthes is initiating a voluntary medical device recall of unexpired and unopened part and lot numbers for the Norian Drillable Injects-Sterile due to the rotary pouch within the referenced lots and associated part numbers may potenti | 2812 units | 2017-03-10 |
| Synthes (USA) Products LLC | 510(k) number | 2016-05-11 | Class II | Under Investigation by firm | DePuy Synthes is initiating a voluntary medical device recall of unexpired and unopened part and lot numbers for the Norian Drillable Injects-Sterile due to the rotary pouch within the referenced lots and associated part numbers may potenti | 2098 units | 2017-03-10 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.