Orthoblast II Paste

OrthoBlast II Paste, 8cc - derived from selected donated human bone tissue that has been processed into particles. The particles are subsequently demineralized using a hydrochloric acid…

Registry build 21.09.26

OrthoBlast II Paste, 8cc – derived from selected donated human bone tissue that has been processed into particles. The particles are subsequently demineralized using a hydrochloric acid process. The demineralized bone matrix (DBM) is combined with a reverse phase carrier, cancellous chips from the same donor, and then formulated to a paste or putty-like consistency.

2manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Shanghai (1), Beijing (1).

Chinese manufacturers registered for FDA product code MQV
Manufacturer City Province Registered as Device types
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Allgens Medical Technology Co., Ltd. Beijing Beijing Complaint-file establishment 1

Record

Regulatory record for Orthoblast II Paste
Listed by Isotis Orthobiologics, Inc, United States
FDA product code MQV
Device type Filler, Bone Void, Calcium Compound
Device class Class 2
Regulation 21 CFR 888.3045
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
Record published 2015-09-24
Record revised 2018-03-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, serial number
Storage Storage environment temperature 15 to 30 °C

Catalogue Numbers

Catalogue numbers for Orthoblast II Paste
Catalogue number Size Status
02-2100-080 8cc In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Synthacer medArtis Medizinprodukte und Forschung Aktiengesellschaft 360
Syntricer medArtis Medizinprodukte und Forschung Aktiengesellschaft 357
Biosorb S.B.M 65
MagnetOs Kuros Biosciences B.V 61
BioSet® Rti Surgical, Inc. 47
Bicera® Resorbable Bone Substitute Wiltrom Corporation Limited 41
GRAFTON®and Grafton PLUS®Demineralized Bone Matrix (DBM) Medtronic Sofamor Danek, Inc. 40
Bicera® Resorbable Bone Substitute Wiltrom Co., Ltd. (Chutung) 39
ChronOS Synthes Gmbh 39
Synthacer/Syntricer medArtis Medizinprodukte und Forschung Aktiengesellschaft 36
Inion BioRestore™ Inion OY 35
Resorba Synthetic Bone Biomatlante 35

Showing 12 of 750. All products under Filler, Bone Void, Calcium Compound

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K070751 2007-10-15
K052098 2005-09-07
K050690 2005-07-07
K040419 2005-03-25

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-07-02 Class II Process control Demineralized bone matrix (DBM) in resorbable mesh indicated for use with autograft as a bone graft extender in the posterolateral spine and pelvis, were filled with approx. 4.5 cc DBM (fill for 45 11 mm configuration) instead of approx. 7 98
2024-11-27 Class II Under Investigation by firm Hydration issue resulting in the product being less cohesive and moldable than intended due to an issue with the polymer. 145
2024-11-27 Class II Labeling Change Control Incorrect expiration date listed on the outer box, which does not align with the correct expiration date listed on the inner tray. 22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer