Cement, Bone, Vertebroplasty
3 catalogue numbers from 0306811000, listed by Stryker GmbH, Switzerland, under Cement, Bone, Vertebroplasty. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (1), Zhejiang (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Shanghai KiNETIC Medical Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Ningbo Hicren Biotechnology Co., Ltd. | Ningbo | Zhejiang | Manufacturer | 5 |
| Jieno Youcheng Medical Technology (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 3 |
| Dragon Crown Medical Co., Ltd. | Jinan | Shandong | Manufacturer | 2 |
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | NDN |
| Device type | Cement, Bone, Vertebroplasty |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3027 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2018-09-24 |
| Record revised | 2021-09-20 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Pack of 6 |
| Sizes | Needle gauge 8 to 11 G |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 0306811000 | Needle Gauge 11.0 G | In distribution |
| 0306810000 | Needle Gauge 10.0 G | In distribution |
| 0306808000 | Needle Gauge 8.0 G | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Zavation | Zavation | 284 |
| CD Horizon® Fenestrated Screw Set | Medtronic Sofamor Danek, Inc. | 88 |
| StabiliT® | Merit Medical Systems, Inc. | 42 |
| Medinaut Plus Kyphoplasty System | Imedicom Co., Ltd. | 41 |
| iVAS | Stryker GmbH | 35 |
| V-Strut Vertebral Implant | Hyprevention | 28 |
| Tracker Plus Kyphoplasty System | GS Medical Co., Ltd. | 25 |
| StabiliT MX Fracture Kit | Dfine, Inc. | 12 |
| Osseoflex® | Merit Medical Systems, Inc. | 8 |
| Synth™ BES | Imedicom Co., Ltd. | 8 |
| Tracker | GS Medical Co., Ltd. | 6 |
| AVAflex | Stryker GmbH | 6 |
Showing 12 of 210. All products under Cement, Bone, Vertebroplasty
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K202393 | 2020-10-20 |
| K150582 | 2015-06-12 |
| K123942 | 2013-04-03 |
| K113154 | 2012-01-24 |
| K103807 | 2011-06-28 |
| K091606 | 2009-10-23 |
| K072118 | 2007-12-07 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-11-09 | Class II | Environmental control | Lack of sterility assurance as bioburden levels were found to be higher than internal acceptable rates. | 51 | 2019-04-16 |
| 2016-06-14 | Class II | Process control | The Piston Head can become separated from the Delivery Piston, blocking the injection assembly Valve resulting in a cement backflow towards the injector handle. Potential for delay in surgery if additional cement needs to be prepared for t | 4,841 boxes (9,682 units) | 2017-03-27 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.