Spider Kolibri

The Spider KOLIBRI Cement Needle is used in spinal procedures for pathological compression fractures associated with osteoporosis or benign or malignant lesions. Its indicated system role…

Registry build 21.09.26

The Spider KOLIBRI Cement Needle is used in spinal procedures for pathological compression fractures associated with osteoporosis or benign or malignant lesions. Its indicated system role includes creating a cavity in cancellous bone and use with compatible PMMA bone cement.

The needle is fully cannulated, with a threaded proximal portion that screws into the pedicle to establish a temporary connection during cement injection. Openings at the distal end allow cement to flow out around the needle.

Injection Connection

A luer lock connects the needle to standard syringes or other cement injection equipment. The needle is supplied in labeled sterile packaging. Bone cement is a separate material used with the system.

5manufacturers in China registered for this device type
6catalogue numbers in this listing
1510(k) clearance

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (1), Zhejiang (1).

Chinese manufacturers registered for FDA product code NDN
Manufacturer City Province Registered as Device types
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Shanghai KiNETIC Medical Co Ltd Shanghai Shanghai Contract manufacturer 19
Ningbo Hicren Biotechnology Co., Ltd. Ningbo Zhejiang Manufacturer 5
Jieno Youcheng Medical Technology (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 3
Dragon Crown Medical Co., Ltd. Jinan Shandong Manufacturer 2

Record

Regulatory record for Spider Kolibri
Listed by Sintea Plustek, United States
FDA product code NDN
Device type Cement, Bone, Vertebroplasty
Device class Class 2
Regulation 21 CFR 888.3027
510(k) K130402
Record published 2015-10-16
Record revised 2018-07-06 (version 4)

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Spider Kolibri
Catalogue number Size Status
SPS-27S540 In distribution
SPS-27S645 In distribution
SPS-27S550 In distribution
SPS-26S550 In distribution
SPS-26S540 In distribution
SPS-26S645 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Zavation Zavation 284
CD Horizon® Fenestrated Screw Set Medtronic Sofamor Danek, Inc. 88
StabiliT® Merit Medical Systems, Inc. 42
Medinaut Plus Kyphoplasty System Imedicom Co., Ltd. 41
iVAS Stryker GmbH 35
V-Strut Vertebral Implant Hyprevention 28
Tracker Plus Kyphoplasty System GS Medical Co., Ltd. 25
StabiliT MX Fracture Kit Dfine, Inc. 12
Osseoflex® Merit Medical Systems, Inc. 8
Synth™ BES Imedicom Co., Ltd. 8
Tracker GS Medical Co., Ltd. 6
AVAflex Stryker GmbH 6

Showing 12 of 210. All products under Cement, Bone, Vertebroplasty

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K130402 2013-04-01

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer