Triathlon

33 catalogue numbers from 5630-G-110, listed by Howmedica Osteonics Corp, United States, under Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer. 3 manufacturers in China are registered for this product code.

Registry build 21.09.26
3manufacturers in China registered for this device type
33catalogue numbers in this listing
1510(k) clearance
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NPJ
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35

Record

Regulatory record for Triathlon
Listed by Howmedica Osteonics Corp, United States
FDA product code NPJ
Device type Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
510(k) K071881
Record published 2015-09-24
Record revised 2025-03-21 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Triathlon
Catalogue number Size Status
5630-G-110 Size: 1 In distribution
5630-G-212-E Side: Left Medial/Right Lateral In distribution
5630-G-229 Side: Right Medial/Left Lateral In distribution
5630-G-429 Side: Right Medial/Left Lateral In distribution
5630-G-228-E Side: Right Medial/Left Lateral In distribution
5630-G-120-E Side: Right Medial/Left Lateral In distribution
5630-G-428 Side: Right Medial/Left Lateral In distribution
5630-G-210-E Side: Left Medial/Right Lateral In distribution
5610-F-101 Size: 1 In distribution
5630-G-510 Side: Left Medial/Right Lateral In distribution
5630-G-528-E Size: 5 In distribution
5630-G-312-E Thickness: 12.0 Millimeter In distribution
5630-G-329-E Size: 3 In distribution
5610-F-502 Size: 5 In distribution
5630-G-322 Side: Right Medial/Left Lateral In distribution
5630-G-520-E Thickness: 10.0 Millimeter In distribution
5550-L-360 Thickness: 10.0 Millimeter In distribution
5610-F-102 Size: 1 In distribution
5620-B-402 Size: 4 In distribution
5630-G-308 Side: Left Medial/Right Lateral In distribution
5630-G-220 Size: 2 In distribution
5630-G-329 Size: 3 In distribution
5610-F-601 Size: 6 In distribution
5630-G-512 Thickness: 12.0 Millimeter In distribution
5630-G-628-E Size: 6 In distribution
5610-F-202 Size: 2 In distribution
5630-G-328-E Side: Right Medial/Left Lateral In distribution
5630-G-608-E Side: Left Medial/Right Lateral In distribution
5630-G-228 Size: 2 In distribution
5550-L-391 Type: Symetric In distribution
5630-G-128 Side: Right Medial/Left Lateral In distribution
5630-G-528 Size: 5 In distribution
5630-G-612 Size: 6 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Restoris Mako Surgical Corp. 101
Sigma Depuy (Ireland) 64
Instrument Howmedica Osteonics Corp 62
Journey Smith & Nephew, Inc. 24
iDuo® iPoly™ Insert Kit ConforMIS, Inc. 15
Restoris Esyntial Mako Surgical Corp. 13
Mako Mako Surgical Corp. 7
Specialty Triathlon TS Trial Assessment Guide Size 8 Right Howmedica Osteonics Corp 6
iDuo® Patella Trial ConforMIS, Inc. 4
Unix Howmedica Osteonics Corp 3
iDuo® Patella Sizer ConforMIS, Inc. 3
iDuo® Patella ConforMIS, Inc. 2

Showing 12 of 21. All products under Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K052917 2005-12-27

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Triathlon
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Howmedica Osteonics Corp 510(k) number 2008-11-25 Not classified Labeling mix-ups Label mix-up: Stryker Orthopaedics became aware of a lot for lot mix up between Triathlon PKR Insert X3 #1 LM/RL 8mm, 5630-G-108 lot code NXDMEE and Triathlon PKR Insert X3 #1 RM/LL- 12 mm 5630-G-122 lot code M8JMEE. 8 mm – 1 unit; 12 mm – 8 units. 2010-08-30

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-30 Not classified Process change control Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to 12,156 US
2011-08-17 Not classified Other Two National Joint Registries suggest that the EIUS Unicompartmental System is associated with a higher revision rate then the unicompartmental devices. 26,648 units 2014-03-26
2004-10-27 Not classified Other The fatigue testing of the Triathlon PS Femoral Component does not consistently meet the requirements of the finite element analysis predicted load as delineated in the 510(k) submittal. 386 UNITS 2005-05-31

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer