Zimmer® DTO®
Zimmer® DTO® Pin press
Who Else Makes It
Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
Record
| Listed by | Zimmer, Inc., United States |
|---|---|
| FDA product code | NQP |
| Device type | Posterior Metal/Polymer Spinal System, Fusion |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3070 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K101704 |
| Record published | 2016-08-29 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Sizes | Length 40 to 100 mm |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 01.03799.058 | In distribution | ||
| 01.03791.080 | Length 80 mm | 2 | In distribution |
| 01.03791.050 | Length 50 mm | 2 | In distribution |
| 01.03791.090 | Length 90 mm | 2 | In distribution |
| 01.03791.050 | Length 50 mm | 2 | In distribution |
| 01.03791.060 | Length 60 mm | 2 | In distribution |
| 01.03791.080 | Length 80 mm | 2 | In distribution |
| 01.03791.070 | Length 70 mm | 2 | In distribution |
| 01.03791.060 | Length 60 mm | 2 | In distribution |
| 01.03791.100 | Length 100 mm | 2 | In distribution |
| 01.03791.100 | Length 100 mm | 2 | In distribution |
| 01.03791.040 | Length 40 mm | 2 | In distribution |
| 01.03791.090 | Length 90 mm | 2 | In distribution |
| 01.03791.070 | Length 70 mm | 2 | In distribution |
| 01.03791.040 | Length 40 mm | 2 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 311 |
| Transition | Globus Medical, Inc. | 278 |
| Dynesys® | Zimmer, Inc. | 139 |
| Dynesys® Top-Loading System | Zimmer, Inc. | 103 |
| Dynesys® | Zimmer Spine, Inc. | 29 |
| CD Horizon™ Astute™ Spinal System | Medtronic Sofamor Danek, Inc. | 9 |
| Dynesys Dynamic Stabilization System | Highridge Medical, LLC | 5 |
| DSS Pedicle screw set, Ø5.0 x 30mm | Paradigm Spine GmbH | 2 |
| DSS Pedicle screw set, Ø5.0 x 40mm | Paradigm Spine GmbH | 2 |
| DSS Pedicle screw set, Ø7.0 x 45mm | Paradigm Spine GmbH | 2 |
| DSS Pedicle screw set, Ø5.0 x 50mm | Paradigm Spine GmbH | 2 |
| DSS Pedicle screw set, Ø8.0 x 50mm | Paradigm Spine GmbH | 2 |
Showing 12 of 83. All products under Posterior Metal/Polymer Spinal System, Fusion
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 1575 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthru, Switzerland, after receiving four complaints of a discrepancy between product patient | 1247 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 2014-04-16 | |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 1406 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 5069 | 2014-04-16 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 58 | 2014-04-16 |
| 2009-05-28 | Not classified | Other | The spacer cutter may jam during surgery, preventing use of the instrument and causing surgical delay. | 177 | 2011-10-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.