Zimmer® DTO®

Zimmer® DTO® Pin press

Registry build 21.09.26
4manufacturers in China registered for this device type
15catalogue numbers in this listing
7recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NQP
Manufacturer City Province Registered as Device types
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53

Record

Regulatory record for Zimmer® DTO®
Listed by Zimmer, Inc., United States
FDA product code NQP
Device type Posterior Metal/Polymer Spinal System, Fusion
Device class Class 2
Regulation 21 CFR 888.3070
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K101704
Record published 2016-08-29
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Sizes Length 40 to 100 mm

Catalogue Numbers

Catalogue numbers for Zimmer® DTO®
Catalogue number Size Per pack Status
01.03799.058 In distribution
01.03791.080 Length 80 mm 2 In distribution
01.03791.050 Length 50 mm 2 In distribution
01.03791.090 Length 90 mm 2 In distribution
01.03791.050 Length 50 mm 2 In distribution
01.03791.060 Length 60 mm 2 In distribution
01.03791.080 Length 80 mm 2 In distribution
01.03791.070 Length 70 mm 2 In distribution
01.03791.060 Length 60 mm 2 In distribution
01.03791.100 Length 100 mm 2 In distribution
01.03791.100 Length 100 mm 2 In distribution
01.03791.040 Length 40 mm 2 In distribution
01.03791.090 Length 90 mm 2 In distribution
01.03791.070 Length 70 mm 2 In distribution
01.03791.040 Length 40 mm 2 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 311
Transition Globus Medical, Inc. 278
Dynesys® Zimmer, Inc. 139
Dynesys® Top-Loading System Zimmer, Inc. 103
Dynesys® Zimmer Spine, Inc. 29
CD Horizon™ Astute™ Spinal System Medtronic Sofamor Danek, Inc. 9
Dynesys Dynamic Stabilization System Highridge Medical, LLC 5
DSS Pedicle screw set, Ø5.0 x 30mm Paradigm Spine GmbH 2
DSS Pedicle screw set, Ø5.0 x 40mm Paradigm Spine GmbH 2
DSS Pedicle screw set, Ø7.0 x 45mm Paradigm Spine GmbH 2
DSS Pedicle screw set, Ø5.0 x 50mm Paradigm Spine GmbH 2
DSS Pedicle screw set, Ø8.0 x 50mm Paradigm Spine GmbH 2

Showing 12 of 83. All products under Posterior Metal/Polymer Spinal System, Fusion

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 1575 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthru, Switzerland, after receiving four complaints of a discrepancy between product patient 1247 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 1406 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 5069 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 58 2014-04-16
2009-05-28 Not classified Other The spacer cutter may jam during surgery, preventing use of the instrument and causing surgical delay. 177 2011-10-05

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer