Endoskeleton® TCS

11 catalogue numbers from 5366-1408, listed by Medtronic Sofamor Danek, Inc., United States, under Intervertebral Fusion Device With Bone Graft, Cervical. 7 manufacturers in China are registered for this product code.

Registry build 21.09.26
7manufacturers in China registered for this device type
11catalogue numbers in this listing
2510(k) clearances naming this product code

Who Else Makes It

Concentrated in Shanghai (2), Shandong (2), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code ODP
Manufacturer City Province Registered as Device types
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Zhisu Health Tech Jiaxing Co., Ltd. Tongxiang Zhejiang Contract manufacturer 4
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Zhejiang Decans Medical Devices Co., Ltd. Jiaxing Zhejiang Manufacturer 10
Shanghai Sanyou Medical Co., Ltd. Shanghai Shanghai Manufacturer 6

Record

Regulatory record for Endoskeleton® TCS
Listed by Medtronic Sofamor Danek, Inc., United States
FDA product code ODP
Device type Intervertebral Fusion Device With Bone Graft, Cervical
Device class Class 2
Regulation 21 CFR 888.3080
510(k) K142940
Record published 2016-12-15
Record revised 2025-07-14 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Sizes Height 5 to 12 mm; width 14 to 18 mm; angle 6 °; depth 12 to 16 mm; outer diameter 2 mm; length 10 in
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Endoskeleton® TCS
Catalogue number Size Status
5366-1408 Width 16 mm In distribution
5386-1608 Angle 6 ° In distribution
5210-1073 Outer Diameter 2 mm In distribution
5386-1612 Angle 6 ° In distribution
5366-1412 16 x 14 (M/L x A/P) mm In distribution
5346-1212 Width 14 mm In distribution
5386-1610 Width 18 mm In distribution
5346-1211 Width 14 mm In distribution
5346-1205 14 x 12 (M/L x A/P) mm In distribution
5386-1606 Depth 16 mm In distribution
5386-1609 Angle 6 ° In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Latitude-C AM™ Cervical Interbody Fusion System Degen Medical 1,529
IdentiTi Alphatec Spine, Inc. 1,390
Zavation Zavation 1,357
IVA Cage Ti Diomedical Co., Ltd. 1,202
Latitude-C Cervical Interbody Spacer System Degen Medical 1,185
Peridot Anterior Cervical Intervertebral Body Fusion System Gbs Commonwealth Co., Ltd. 1,056
Aleutian® Interbody Systems VB Spine LLC 1,017
Valeo Spacer System Sintx Technologies Inc. 918
Cascadia™ Interbody System VB Spine LLC 823
CoRoent Nuvasive, Inc. 815
Tyber Medical Tyber Medical 740
Matisse Anterior Cervical Interbody Fusion Cage System CTL Medical Corporation 577

Showing 12 of 938. All products under Intervertebral Fusion Device With Bone Graft, Cervical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K153373 2016-01-19
K100214 2010-06-25

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Endoskeleton® TCS
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Medtronic Sofamor Danek USA, Inc. 510(k) number 2021-09-02 Class II Packaging change control Engraving on implants may not match what is listed on the pouch labels. 9 units 2023-10-05
Titan Spine, LLC 510(k) number 2015-07-20 Class II Nonconforming Material/Component Titan Spine is recalling specific Endoskeleton TCS Integrated Locking Bone Screw Assembly due to the locking bone screw collars not ‘locking’. 137 units 2015-10-20
Titan Spine, LLC 510(k) number 2015-02-20 Class II Nonconforming Material/Component The TCS Straight Hexlobular #6 Drivers (5210-1004) tip sheared off during use in procedures that involved patients with dense bones. As a result of this malfunction, Titan Spine, LLC is removing all of the TCS Straight Hex lobular #6 Drive 26 2015-04-17

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer