Endoskeleton® TCS Sterile Barrier System
39 catalogue numbers from 5301-3515-S, listed by Titan Spine, LLC, United States, under Intervertebral Fusion Device With Bone Graft, Cervical. 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (2), Shandong (2), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Zhisu Health Tech Jiaxing Co., Ltd. | Tongxiang | Zhejiang | Contract manufacturer | 4 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
| Shanghai Sanyou Medical Co., Ltd. | Shanghai | Shanghai | Manufacturer | 6 |
Record
| Listed by | Titan Spine, LLC, United States |
|---|---|
| FDA product code | ODP |
| Device type | Intervertebral Fusion Device With Bone Graft, Cervical |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3080 |
| 510(k) | K151596 |
| Record published | 2016-12-15 |
| Record revised | 2025-07-14 (version 11) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Sizes | Width 14 to 18 mm; depth 12 to 16 mm; height 5 to 12 mm; angle 6 °; outer diameter 3.5 to 3.8 mm; length 13 to 20 mm |
| Distribution end date | 2021-03-01 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5301-3515-S | Outer Diameter 3.5 mm | In distribution |
| 5366-1410-S | Width 16 mm | Withdrawn |
| 5386-1609-S | Depth 16 mm | Withdrawn |
| 5366-1407-S | width(MLxAP), 16 x 14, mm | Withdrawn |
| 5301-3517-S | Standard Bone Screw | Withdrawn |
| 5386-1608-S | Depth 16 mm | Withdrawn |
| 5302-3520-S | Length 20 mm | Withdrawn |
| 5360-1407-S | Depth 14 mm | Withdrawn |
| 5386-1611-S | Angle 6 ° | Withdrawn |
| 5360-1412-S | Depth 14 mm | Withdrawn |
| 5380-1605-S | width(MLxAP), 18 x 16, mm | Withdrawn |
| 5340-1210-S | Width 14 mm | Withdrawn |
| 5301-3817-S | 3.8mm Diameter, 17mm Length, No. 8 Hexalobe | Withdrawn |
| 5346-1208-S | Width 14 mm | Withdrawn |
| 5302-3517-S | 3.5mm Diameter, 17mm Length, No. 8 Hexalobe | Withdrawn |
| 5386-1605-S | Depth 16 mm | Withdrawn |
| 5386-1607-S | width(MLxAP), 18 x 16, mm | Withdrawn |
| 5301-3520-S | Standard Bone Screw | Withdrawn |
| 5302-3519-S | Outer Diameter 3.8 mm | Withdrawn |
| 5302-3813-S | 3.8mm Diameter, 13mm Length, No. 8 Hexalobe | Withdrawn |
| 5346-1206-S | Angle 6 ° | Withdrawn |
| 5301-3820-S | Outer Diameter 3.5 mm | Withdrawn |
| 5366-1412-S | Depth 14 mm | Withdrawn |
| 5380-1606-S | Width 18 mm | Withdrawn |
| 5302-3817-S | Outer Diameter 3.8 mm | Withdrawn |
| 5301-3815-S | Length 15 mm | Withdrawn |
| 5360-1410-S | Depth 14 mm | Withdrawn |
| 5386-1612-S | width(MLxAP), 18 x 16, mm | Withdrawn |
| 5380-1607-S | Depth 16 mm | Withdrawn |
| 5302-3820-S | Locking Bone Screw | Withdrawn |
| 5346-1209-S | Angle 6 ° | Withdrawn |
| 5340-1206-S | width(MLxAP), 14 x 12, mm | Withdrawn |
| 5340-1209-S | Width 14 mm | Withdrawn |
| 5380-1611-S | Depth 16 mm | Withdrawn |
| 5386-1610-S | Depth 16 mm | Withdrawn |
| 5346-1210-S | width(MLxAP), 14 x 12, mm | Withdrawn |
| 5366-1408-S | width(MLxAP), 16 x 14, mm | Withdrawn |
| 5360-1409-S | Depth 14 mm | Withdrawn |
| 5346-1205-S | Angle 6 ° | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Latitude-C AM™ Cervical Interbody Fusion System | Degen Medical | 1,529 |
| IdentiTi | Alphatec Spine, Inc. | 1,390 |
| Zavation | Zavation | 1,357 |
| IVA Cage Ti | Diomedical Co., Ltd. | 1,202 |
| Latitude-C Cervical Interbody Spacer System | Degen Medical | 1,185 |
| Peridot Anterior Cervical Intervertebral Body Fusion System | Gbs Commonwealth Co., Ltd. | 1,056 |
| Aleutian® Interbody Systems | VB Spine LLC | 1,017 |
| Valeo Spacer System | Sintx Technologies Inc. | 918 |
| Cascadia™ Interbody System | VB Spine LLC | 823 |
| CoRoent | Nuvasive, Inc. | 815 |
| Tyber Medical | Tyber Medical | 740 |
| Matisse Anterior Cervical Interbody Fusion Cage System | CTL Medical Corporation | 577 |
Showing 12 of 938. All products under Intervertebral Fusion Device With Bone Graft, Cervical
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K192018 | 2019-08-16 |
| K183557 | 2019-02-11 |
| K173535 | 2018-02-13 |
| K100889 | 2010-07-29 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Medtronic Sofamor Danek USA, Inc. | 510(k) number | 2021-09-02 | Class II | Packaging change control | Engraving on implants may not match what is listed on the pouch labels. | 9 units | 2023-10-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.