Mecta-C Cervical Cages
Mecta-C is a cervical interbody cage placed between vertebral bodies during anterior fusion surgery. It is intended for skeletally mature patients with cervical disc disease at one level…
Mecta-C is a cervical interbody cage placed between vertebral bodies during anterior fusion surgery. It is intended for skeletally mature patients with cervical disc disease at one level from C2 to T1 after six weeks of nonoperative treatment.
The cage has a PEEK body with a hollow interior for packing the patient’s own bone graft. Tantalum markers at the ends allow the position and orientation of the otherwise radiolucent cage to be assessed on X-ray images.
Listed Item
Cervical Interbody Fusion Device Dome Shaped 12x14x5 L5°
Fusion Construct
Mecta-C must be used with autogenous bone graft and supplemental spinal fixation. One cage may be used in each treated intervertebral space. The range includes different footprints, heights, and lordotic shapes to suit the anatomy.
Who Else Makes It
Concentrated in Shanghai (2), Shandong (2), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Zhisu Health Tech Jiaxing Co., Ltd. | Tongxiang | Zhejiang | Contract manufacturer | 4 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
| Shanghai Sanyou Medical Co., Ltd. | Shanghai | Shanghai | Manufacturer | 6 |
Record
| Listed by | Medacta International SA, Switzerland |
|---|---|
| FDA product code | ODP |
| Device type | Intervertebral Fusion Device With Bone Graft, Cervical |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3080 |
| Establishment | Specification developer, Repacker / relabeller, Private-label distributor, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K112862 |
| Record published | 2014-11-18 |
| Record revised | 2025-07-14 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 03.28.502 | In distribution | |
| 03.28.404 | In distribution | |
| 03.28.503 | In distribution | |
| 03.28.521 | In distribution | |
| 03.28.519 | In distribution | |
| 03.28.429 | In distribution | |
| 03.28.403 | In distribution | |
| 03.28.526 | In distribution | |
| 03.28.501 | In distribution | |
| 03.28.523 | In distribution | |
| 03.28.529 | In distribution | |
| 03.28.410 | In distribution | |
| 03.28.515 | In distribution | |
| 03.28.430 | In distribution | |
| 03.28.518 | In distribution | |
| 03.28.505 | In distribution | |
| 03.28.415 | In distribution | |
| 03.28.418 | In distribution | |
| 03.28.419 | In distribution | |
| 03.28.417 | In distribution | |
| 03.28.525 | In distribution | |
| 03.28.509 | In distribution | |
| 03.28.407 | In distribution | |
| 03.28.425 | In distribution | |
| 03.28.424 | In distribution | |
| 03.28.423 | In distribution | |
| 03.28.409 | In distribution | |
| 03.28.428 | In distribution | |
| 03.28.524 | In distribution | |
| 03.28.427 | In distribution | |
| 03.28.420 | In distribution | |
| 03.28.528 | In distribution | |
| 03.28.514 | In distribution | |
| 03.28.513 | In distribution | |
| 03.28.416 | In distribution | |
| 03.28.506 | In distribution | |
| 03.28.508 | In distribution | |
| 03.28.510 | In distribution | |
| 03.28.527 | In distribution | |
| 03.28.511 | In distribution | |
| 03.28.406 | In distribution | |
| 03.28.401 | In distribution | |
| 03.28.504 | In distribution | |
| 03.28.522 | In distribution | |
| 03.28.530 | In distribution | |
| 03.28.408 | In distribution | |
| 03.28.405 | In distribution | |
| 03.28.412 | In distribution | |
| 03.28.411 | In distribution | |
| 03.28.422 | In distribution | |
| 03.28.507 | In distribution | |
| 03.28.421 | In distribution | |
| 03.28.520 | In distribution | |
| 03.28.512 | In distribution | |
| 03.28.516 | In distribution | |
| 03.28.426 | In distribution | |
| 03.28.402 | In distribution | |
| 03.28.414 | In distribution | |
| 03.28.413 | In distribution | |
| 03.28.517 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Latitude-C AM™ Cervical Interbody Fusion System | Degen Medical | 1,529 |
| IdentiTi | Alphatec Spine, Inc. | 1,390 |
| Zavation | Zavation | 1,357 |
| IVA Cage Ti | Diomedical Co., Ltd. | 1,202 |
| Latitude-C Cervical Interbody Spacer System | Degen Medical | 1,185 |
| Peridot Anterior Cervical Intervertebral Body Fusion System | Gbs Commonwealth Co., Ltd. | 1,056 |
| Aleutian® Interbody Systems | VB Spine LLC | 1,017 |
| Valeo Spacer System | Sintx Technologies Inc. | 918 |
| Cascadia™ Interbody System | VB Spine LLC | 823 |
| CoRoent | Nuvasive, Inc. | 815 |
| Tyber Medical | Tyber Medical | 740 |
| Matisse Anterior Cervical Interbody Fusion Cage System | CTL Medical Corporation | 577 |
Showing 12 of 938. All products under Intervertebral Fusion Device With Bone Graft, Cervical
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K142744 | 2015-05-07 |
| K112862 | 2011-12-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.