Maxim® Knee System
Catalogue number 140071, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive. 8 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (2), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | OIY |
| Device type | Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3560 |
| 510(k) | K033489 |
| Record published | 2020-05-18 |
| Record revised | 2025-05-30 (version 2) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 140071 | 60mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Persona® | Zimmer, Inc. | 552 |
| DJO Surgical | Encore Medical, L.P. | 415 |
| Genflex2 Total Knee System | Globus Medical, Inc. | 389 |
| Persona® Vivacit-E® | Zimmer, Inc. | 332 |
| Truliant, Activit-E | Exactech, Inc. | 272 |
| TriVerse Meniscal Insert PS | Signature Orthopaedics PTY Limited | 220 |
| U2™ Knee | United Orthopedic Corp. | 195 |
| BKS E-Vitalize | Ortho Development Corp. | 193 |
| Vanguard XP Instrumentation | Biomet Orthopedics | 169 |
| Attune | Depuy (Ireland) | 161 |
| Vanguard Complete Knee System | Biomet Orthopedics | 153 |
| EXp Tibial Inserts and Patellar Components | Globus Medical, Inc. | 144 |
Showing 12 of 102. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
Recalls Naming This Product
9 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2018-12-21 | Class II | Under Investigation by firm | Vanguard Knee System Series-A Standard Patella a potential commingle that could result in the size of the implant not matching the size on the label. | 90 units | 2020-05-13 |
| Biomet, Inc. | 510(k) number | 2018-05-24 | Class II | Under Investigation by firm | Two lots of tibial bearings were commingled. There is a possibility that a 14mm tibial bearing is packaged in a box labeled as 12 mm tibial bearing and vice versa. This may lead to extension of surgery to find another implant. | 48 | 2020-04-07 |
| Biomet, Inc. | 510(k) number | 2018-05-18 | Class II | Under Investigation by firm | One lot of 75mm tibial tray is potentially etched and labeled as a 79 mm tibial tray. This may lead to delay in surgery, or immediate revision surgery to remove an incorrectly sized tibial component after it has been cemented. | 16 | 2020-03-31 |
| Biomet, Inc. | 510(k) number | 2018-05-11 | Class II | Under Investigation by firm | The label master file was errantly set up as a 63/37mm instead of a 63/67mm. There is no 63/37 size offered, and the product is laser marked with the correct size. | 169 | 2019-11-21 |
| Biomet, Inc. | 510(k) number | 2015-04-16 | Class III | Labeling mix-ups | Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes. | 1315 | 2016-05-16 |
| Biomet, Inc. | 510(k) number | 2011-03-03 | Not classified | Packaging process control | The firm is recalling the product due to the product’s packaging being labeled “I-Beam 75mm. Tibial Plate”, but the package actually contains the “Interlok 67mm. CR Tibial Plate”. | 8 | 2011-07-27 |
| Biomet, Inc. | 510(k) number | 2007-12-12 | Not classified | Packaging process control | Mislabeled as to size: Package labeled as containing a 67 mm tray actually contains a 75 mm tray and vice versa. | 8 | 2008-06-11 |
| Biomet, Inc. | 510(k) number | 2007-12-12 | Not classified | Packaging process control | Mislabeled as to size: Package labeled as containing a 67 mm tray actually contains a 75 mm tray and vice versa. | 8 | 2008-06-11 |
| Biomet, Inc. | 510(k) number | 2007-09-18 | Not classified | Labeling mix-ups | Mislabeled as to size: the package actaully contained a 71 mm tray. | 7 | 2008-06-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.