Identity Imprint Knee Replacement System
PS Tibial Insert Trial Size 3 18MM Left AND Right
Who Else Makes It
Concentrated in Shanghai (1), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
Record
| Listed by | ConforMIS, Inc., United States |
|---|---|
| FDA product code | OOG |
| Device type | Knee Arthroplasty Implantation System |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3560 |
| Establishment | Remanufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K210191 |
| Record published | 2021-06-07 |
| Record revised | 2023-07-13 (version 3) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| TPS020164S01 | In distribution | |
| TPS020143S01 | SIZE 3 14MM THICKNESS | In distribution |
| TPS030183S01 | SIZE 3 18MM THICKNESS | In distribution |
| TPS301T02N01 | tibial tray size 2 narrow | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prophecy | Microport Orthopedics Inc. | 1,463 |
| PointCloud Knee Instruments | Unik Orthopedics, Inc | 202 |
| iTotal Identity CR | ConforMIS, Inc. | 138 |
| My Knee Femoral Cutting Blocks | Medacta International SA | 60 |
| iTotal® CR iPoly™ Insert Kit | ConforMIS, Inc. | 59 |
| My Knee Tibial Cutting Blocks | Medacta International SA | 48 |
| My Knee Femoral Cutting Blocks MIS | Medacta International SA | 42 |
| My Knee Tibial Cutting Blocks MIS | Medacta International SA | 36 |
| iTotal® Identity Cruciate Retaining Knee Replacement System | ConforMIS, Inc. | 27 |
| iTotal® CR iPoly® XE Insert Kit | ConforMIS, Inc. | 16 |
| Zimmer Patient Specific Instruments | Materialise NV | 12 |
| iTotal Identity CR Knee Replacement System | ConforMIS, Inc. | 12 |
Showing 12 of 95. All products under Knee Arthroplasty Implantation System
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K203421 | 2021-04-19 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| ConforMIS, Inc. | 510(k) number | 2024-03-11 | Class II | Process design | Size 5 Tibial Tray from Lot 508287 was packaged in a Size 4 box from Lot 540287. It was confirmed that Lot 540287 and Lot 508287 were swapped between the pouching and final pack. | 3 units |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2015-08-31 | Class II | Process design | May contain small amounts of ethylene glycol residue | 7 units | 2016-03-02 |
| 2015-08-31 | Class II | Process design | May contain small amounts of ethylene glycol residue | 71 units | 2016-03-02 |
| 2015-08-31 | Class II | Process design | May contain small amounts of ethylene glycol residue | 6 units | 2016-03-02 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.